Preliminary Study on the Diagnostic Value of Acoustic Radiation Force Impulse Technology for Differentiating Between Benign and Malignant Thyroid Nodules

被引:0
|
作者
Gu, Jiying [1 ]
Du, Lianfang [1 ]
Bai, Min [1 ]
Chen, Huili [1 ]
Jia, Xiao [1 ]
Zhao, Jing [1 ]
Zhang, Xuemei [2 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 1, Sch Med, Dept Ultrasound, Shanghai 200080, Peoples R China
[2] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 1, Sch Med, Dept Pathol, Shanghai 200080, Peoples R China
关键词
acoustic radiation force impulse; thyroid nodule; sonography; FINE-NEEDLE-ASPIRATION; IN-VIVO; ELASTOGRAPHY; ULTRASOUND; CANCER; US;
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives-This study aimed to evaluate the diagnostic value of acoustic radiation force impulse (ARFI) elasticity imaging for differentiating between benign and malignant thyroid lesions. Methods-Hospitalized patients needing thyroid surgery were evaluated. After routine thyroid sonography, the patients underwent ARFI elasticity imaging. Virtual Touch tissue imaging(VTI) and Virtual Touch tissue quantification (VTQ; Siemens Medical Solutions, Mountain View, CA) were used to qualitatively and quantitatively analyze the elasticity and hardness of nodules. For statistical analysis, the Student t test, analysis of variance, and the chi(2) test were used to compare the elastic parameters. Results-Of the 98 thyroid nodules observed in 72 hospitalized patients, 56 were nodular goiters, 16 thyroid adenomas, 4 thyroiditis, and 22 thyroid malignancies, with mean VTQ values +/- SD of 2.034 +/- 0.484, 1.835 +/- 0.364, 2.293 +/- 0.787, and 3.941 +/- 1.393 m/s, respectively. The elastic parameters of malignant nodules were significantly higher than those of benign nodules (P < .001) and the surrounding thyroid parenchyma (P < .001). There was no significant difference between the VTQ value of benign nodules and that of the surrounding normal thyroid parenchyma (P > .05). For differentiating between benign and malignant nodules, the sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accordance rate were 86.36%, 93.42%, 79.17%, 95.95%, and 91.84% based on the standard VTQ value (2.555m/s). In total, 77.6% (59 of 76) of the benign nodules showed softer and equal images in the VTI mode, and 77.3% (17 of 22) of the malignant nodules showed stiffer images (P < .001). Conclusions-Acoustic radiation force impulse imaging has high sensitivity and specificity in evaluating benign and malignant thyroid nodules and therefore had good diagnostic value in clinical applications.
引用
下载
收藏
页码:763 / 771
页数:9
相关论文
共 50 条
  • [31] Does Lesion Size Affect the Value of Shear Wave Elastography for Differentiating Between Benign and Malignant Thyroid Nodules?
    Wang, Fen
    Chang, Cai
    Chen, Min
    Gao, Yi
    Chen, Ya-Ling
    Zhou, Shi-Chong
    Li, Jia-Wei
    Zhi, Wen-Xiang
    JOURNAL OF ULTRASOUND IN MEDICINE, 2018, 37 (03) : 601 - 609
  • [32] Diagnostic value of PET/CT in differentiating benign from malignant solitary pulmonary nodules
    Dalli, A.
    Sen, H. Selimoglu
    Coskunsel, M.
    Komek, H.
    Abakay, O.
    Sergi, C.
    Tanrikulu, A. Cetin
    JOURNAL OF BUON, 2013, 18 (04): : 935 - 941
  • [33] Diagnostic value of ultrasonography and TI-201/Tc-99m dual scintigraphy in differentiating between benign and malignant thyroid nodules
    Watanabe, Ken
    Igarashi, Takao
    Ashida, Hirokazu
    Ogiwara, Sho
    Ohta, Tomoyuki
    Uchiyama, Mayuki
    Ojiri, Hiroya
    ENDOCRINE, 2019, 63 (02) : 301 - 309
  • [34] Diagnostic value of ultrasonography and TI-201/Tc-99m dual scintigraphy in differentiating between benign and malignant thyroid nodules
    Ken Watanabe
    Takao Igarashi
    Hirokazu Ashida
    Sho Ogiwara
    Tomoyuki Ohta
    Mayuki Uchiyama
    Hiroya Ojiri
    Endocrine, 2019, 63 : 301 - 309
  • [35] Prospective evaluation of acoustic radiation force impulse technology in the differentiation of thyroid nodules: Accuracy and interobserver variability assessment
    Grazhdani H.
    Cantisani V.
    Lodise P.
    Di Rocco G.
    Proietto M.C.
    Fioravanti E.
    Rubini A.
    Redler A.
    Journal of Ultrasound, 2014, 17 (1) : 13 - 20
  • [36] Diagnostic Value of Color Doppler Ultrasonography in Detecting Calcifications in Thyroid Nodules for Benign and Malignant Nodules
    Liu, Xia
    Chang, Defeng
    Xie, Dan
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2020, 10 (07) : 1621 - 1630
  • [37] Ultrasonographic elastography of the breast using acoustic radiation force impulse technology: preliminary study
    Tozaki, Mitsuhiro
    Isobe, Sachiko
    Yamaguchi, Miki
    Ogawa, Yukari
    Homma, Kanako
    Saito, Masahiro
    Joo, Chanwoong
    Fukuma, Eisuke
    JAPANESE JOURNAL OF RADIOLOGY, 2011, 29 (06) : 452 - 456
  • [38] Ultrasonographic elastography of the breast using acoustic radiation force impulse technology: preliminary study
    Mitsuhiro Tozaki
    Sachiko Isobe
    Miki Yamaguchi
    Yukari Ogawa
    Kanako Homma
    Masahiro Saito
    Chanwoong Joo
    Eisuke Fukuma
    Japanese Journal of Radiology, 2011, 29 : 452 - 456
  • [39] Diagnostic efficacy of multiple MRI parameters in differentiating benign vs. malignant thyroid nodules
    Hao Wang
    Ran Wei
    Weiyan Liu
    Yongqi Chen
    Bin Song
    BMC Medical Imaging, 18
  • [40] Diagnostic efficacy of multiple MRI parameters in differentiating benign vs. malignant thyroid nodules
    Wang, Hao
    Wei, Ran
    Liu, Weiyan
    Chen, Yongqi
    Song, Bin
    BMC MEDICAL IMAGING, 2018, 18