Monoclonal antibody heterogeneity analysis and deamidation monitoring with high-performance cation-exchange chromatofocusing using simple, two component buffer systems

被引:19
|
作者
Kang, Xuezhen [1 ]
Kutzko, Joseph P. [1 ]
Hayes, Michael L. [1 ]
Frey, Douglas D. [2 ]
机构
[1] Genzyme, Purificat & Proc Res, Framingham, MA 01701 USA
[2] Univ Maryland Baltimore Cty, Dept Chem Biochem & Environm Engn, Baltimore, MD 21250 USA
基金
美国国家科学基金会;
关键词
Chromatofocusing; Monoclonal antibody; Charge variants; Isoelectric point; PH GRADIENTS; ION-EXCHANGE; EXPERIMENTAL-VERIFICATION; CHROMATOGRAPHIC COLUMNS; RECOMBINANT PROTEINS; RETAINED PH; EQUILIBRIUM; SEPARATIONS; ELUTION; PURIFICATION;
D O I
10.1016/j.chroma.2013.01.101
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The use of either a polyampholyte buffer or a simple buffer system for the high-performance cation-exchange chromatofocusing of monoclonal antibodies is demonstrated for the case where the pH gradient is produced entirely inside the column and with no external mixing of buffers. The simple buffer system used was composed of two buffering species, one which becomes adsorbed onto the column packing and one which does not adsorb, together with an adsorbed ion that does not participate in acid-base equilibrium. The method which employs the simple buffer system is capable of producing a gradual pH gradient in the neutral to acidic pH range that can be adjusted by proper selection of the starting and ending pH values for the gradient as well as the buffering species concentration, pK(a), and molecular size. By using this approach, variants of representative monoclonal antibodies with isoelectric points of 7.0 or less were separated with high resolution so that the approach can serve as a complementary alternative to isoelectric focusing for characterizing a monoclonal antibody based on differences in the isoelectric points of the variants present. Because the simple buffer system used eliminates the use of polyampholytes, the method is suitable for antibody heterogeneity analysis coupled with mass spectrometry. The method can also be used at the preparative scale to collect highly purified isoelectric variants of an antibody for further study. To illustrate this, a single isoelectric point variant of a monoclonal antibody was collected and used for a stability study under forced deamidation conditions. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:89 / 97
页数:9
相关论文
共 49 条
  • [21] ANALYSIS OF HEPATIC REDUCED GLUTATHIONE, CYSTEINE AND HOMOCYSTEINE BY CATION-EXCHANGE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION
    DEMASTER, EG
    SHIROTA, FN
    REDFERN, B
    GOON, DJW
    NAGASAWA, HT
    JOURNAL OF CHROMATOGRAPHY, 1984, 308 (JUN): : 83 - 91
  • [22] CATION-EXCHANGE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY - SEPARATION OF HIGHLY BASIC-PROTEINS USING VOLATILE ACIDIC SOLVENTS
    VANDENEIJNDENVANRAAIJ, AJM
    KOORNNEEF, I
    VANOOSTWAARD, TMJ
    DELAAT, SW
    VANZOELEN, EJJ
    ANALYTICAL BIOCHEMISTRY, 1987, 163 (01) : 263 - 269
  • [23] THE ESTIMATION OF GLUCOSE, GALACTOSE AND RESIDUAL LACTOSE IN HYDROLYZED WHEY PRODUCTS USING CATION-EXCHANGE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    WOOLLARD, DC
    NEW ZEALAND JOURNAL OF DAIRY SCIENCE AND TECHNOLOGY, 1983, 18 (03): : 209 - 224
  • [24] ANALYSIS OF VITAMIN-B6 VITAMERS IN HUMAN-TISSUE BY CATION-EXCHANGE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    SHEPHARD, GS
    VANDERWESTHUIZEN, L
    LABADARIOS, D
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 491 (01): : 226 - 234
  • [25] ANALYSIS OF URONIC AND ALDONIC ACIDS, THEIR LACTONES, AND RELATED-COMPOUNDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ON CATION-EXCHANGE RESINS
    HICKS, KB
    LIM, PC
    HAAS, MJ
    JOURNAL OF CHROMATOGRAPHY, 1985, 319 (02): : 159 - 171
  • [26] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ANALYSIS OF PLATELET-ACTIVATING-FACTOR ON A CATION-EXCHANGE COLUMN BY DIRECT ULTRAVIOLET DETECTION
    ANDRIKOPOULOS, NK
    DEMOPOULOS, CA
    SIAFAKAKAPADAI, A
    JOURNAL OF CHROMATOGRAPHY, 1986, 363 (02): : 412 - 417
  • [27] AUTOMATED QUANTITATION OF POLYAMINES BY IMPROVED CATION-EXCHANGE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING A PUMP EQUIPPED WITH A PLUNGER WASHING SYSTEM
    WATANABE, S
    SATO, S
    NAGASE, S
    TOMITA, M
    SAITO, T
    ISHIZU, H
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1993, 16 (03): : 619 - 632
  • [28] SIMPLE CATION-EXCHANGE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OPTIMIZED TO THE MEASUREMENT OF METABOLITES IN THE EFFLUENTS FROM PERFUSED RAT LIVERS USING REFRACTIVE-INDEX AND ULTRAVIOLET DETECTORS
    MASSON, S
    SCIAKY, M
    DESMOULIN, F
    FONTANARAVA, E
    COZZONE, PJ
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 563 (02): : 231 - 242
  • [29] ANALYSIS OF ENROFLOXACIN AND ITS METABOLITE CIPROFLOXACIN IN BOVINE AND PORCINE MUSCLE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY FOLLOWING CATION-EXCHANGE CLEANUP
    TARBIN, JA
    TYLER, DJ
    SHEARER, G
    FOOD ADDITIVES AND CONTAMINANTS, 1992, 9 (04): : 345 - 350
  • [30] Analysis of 2-difluoromethyl-DL-ornithine in human plasma, cerebrospinal fluid and urine by cation-exchange high-performance liquid chromatography
    Huebert, ND
    Schwartz, JJ
    Haegele, KD
    JOURNAL OF CHROMATOGRAPHY A, 1997, 762 (1-2) : 293 - 298