Analysis of 2-difluoromethyl-DL-ornithine in human plasma, cerebrospinal fluid and urine by cation-exchange high-performance liquid chromatography

被引:10
|
作者
Huebert, ND [1 ]
Schwartz, JJ [1 ]
Haegele, KD [1 ]
机构
[1] HOECHST MARION ROUSSEL,CINCINNATI,OH 45215
关键词
2-difluoromethyl-DL-ornithine;
D O I
10.1016/S0021-9673(96)00818-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An analytical method has been developed based on cation-exchange liquid chromatography for the measurement of 2-difluoromethyl-DL-ornithine (DFMO) in human plasma, cerebrospinal fluid (CSF) and urine. Fluorescence detection at excitation-emission wavelengths of 340/440 nm is followed by postcolumn derivatization with o-phthalaldehyde-2-mercaptoethanol. All calibration ranges yielded linear relationships with correlation coefficients better than 0.999. In each case the limit of quantitation was equal to the lowest value of the standard curve. The variability of the assay, expressed as relative standard deviations, was less than 7.1%, 15.3% and 7.1% for plasma, CSF and urine, respectively. The accuracy of the assay (expressed as relative errors) ranged between -4.3% and 2.0% for plasma analysis, between -0.1% and 14.0% for CSF analysis and between -8.0% and 2.0% for urine analysis. Plasma, CSF and urinary DFMO concentrations were measured in samples obtained from patients undergoing treatment for trypanosomiasis. The method was found to be applicable for the measurement of DFMO levels in human body fluids for the determination of pharmacokinetic parameters in clinical studies.
引用
收藏
页码:293 / 298
页数:6
相关论文
共 50 条
  • [1] High-performance liquid chromatographic method for determination of 2-difluoromethyl-DL-ornithine in plasma and cerebrospinal fluid
    Hanpitakpong, W
    Kamanikom, B
    Banmairuroi, V
    Na-Bangchang, K
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 788 (02): : 221 - 231
  • [2] ANALYSIS OF HUMAN HEMOGLOBINS BY A CATION-EXCHANGE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    OU, CN
    BUFFONE, GJ
    CALLIHAN, JR
    REIMER, GL
    CLINICAL CHEMISTRY, 1983, 29 (06) : 1202 - 1202
  • [3] HIGH-PERFORMANCE CATION-EXCHANGE CHROMATOGRAPHY OF HEXOSAMINITOLS
    HAYASE, T
    LEE, YC
    ANALYTICAL BIOCHEMISTRY, 1993, 208 (01) : 208 - 209
  • [4] HIGH-PERFORMANCE CATION-EXCHANGE CHROMATOGRAPHY OF PROTEINS
    GUPTA, S
    PFANNKOCH, E
    REGNIER, FE
    ANALYTICAL BIOCHEMISTRY, 1983, 128 (01) : 196 - 201
  • [5] DETECTION OF SIALURIA BY CATION-EXCHANGE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    MONONEN, I
    JOURNAL OF CHROMATOGRAPHY, 1986, 381 (02): : 219 - 224
  • [6] ANALYSIS OF VITAMIN-B6 VITAMERS IN PLASMA BY CATION-EXCHANGE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    SHEPHARD, GS
    LOUW, MEJ
    LABADARIOS, D
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 416 (01): : 138 - 143
  • [7] Determination of glutathionyl-hemoglobin in human erythrocytes by cation-exchange high-performance liquid chromatography
    Pastore, A
    Mozzi, AF
    Tozzi, G
    Gaeta, LM
    Federici, G
    Bertini, E
    Russo, AL
    Mannucci, L
    Piemonte, F
    ANALYTICAL BIOCHEMISTRY, 2003, 312 (02) : 85 - 90
  • [8] SEPARATION OF BASIC PEPTIDES BY CATION-EXCHANGE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    CACHIA, PJ
    VANEYK, J
    CHONG, PCS
    TANEJA, A
    HODGES, RS
    JOURNAL OF CHROMATOGRAPHY, 1983, 266 (AUG): : 651 - 659
  • [9] HIGH-PERFORMANCE CATION-EXCHANGE CHROMATOGRAPHY OF BASIC PEPTIDES
    BONIFACE, O
    FOURQUET, P
    BOSCHETTI, E
    GUERRIER, L
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1992, 15 (12): : 2183 - 2203
  • [10] USEFULNESS OF CATION-EXCHANGE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AS A TESTING PROCEDURE
    HUISMAN, THJ
    PEDIATRICS, 1989, 83 (05) : 849 - 851