Ground fault location in radial distribution networks involving distributed voltage measurement

被引:24
|
作者
Zhang, Shu [1 ]
Lin, Sheng [1 ]
He, Zhengyou [1 ]
Lee, Wei-jen [2 ]
机构
[1] Southwest Jiaotong Univ, Dept Elect Engn, Chengdu 610031, Sichuan, Peoples R China
[2] Univ Texas Arlington, Dept Elect Engn, Arlington, TX 76013 USA
基金
中国国家自然科学基金;
关键词
power distribution faults; fault location; voltage measurement; smart meters; power meters; iterative methods; search problems; power system CAD; EMTP; power system measurement; short-circuit currents; ground fault location; radial distribution networks; distributed voltage measurement; short-circuit current; fault resistance; intelligent electronic devices; distribution system monitoring; distribution system automation; smart feeder meters; voltage information; downstream sublaterals; fault lateral identification; zero-sequence components network; nodes position; main lateral; fault section identification; iteration search; power systems computer-aided design; electromagnetic transient design; ground faults identification; distributed generations; dynamic loads; SYSTEMS; SINGLE;
D O I
10.1049/iet-gtd.2017.1166
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Since feeders have complicated laterals connected with unbalanced loads, the location of a ground fault is a challenge in radial distribution networks. Furthermore, lower short-circuit current due to the high value of fault resistance, which is common in the distribution network, will make it even more challenging to identify the fault location. Taking advantage of increasing number of intelligent electronic devices installed in the modern distribution network, the monitoring, and automation of distribution systems can be improved by smart feeder meters. On the basis of the voltage information from the downstream sub-laterals, a novel fault location method involving distributed voltage measurement is proposed in this study. The first step in the proposed method is to identify the fault lateral in the main lateral. In a zero-sequence components network, the position of nodes in the main lateral is iterated to judge if the calculated voltage at the end matches the measured one by a smart feeder meter. The second step is to identify the fault section accurately by combining the voltage information from main lateral or other sub-laterals. Finally, a precise fault location can be attained via an iteration search in the fault section. Two distribution test systems simulated in power systems computer-aided design/electro-magnetic transient design and control with 34-node and 134-node have been employed to evaluate the effectiveness of the proposed algorithm under various ground fault scenarios. The simulation results show that the proposed method is robust since it offered a good performance for ground faults identification with low and high values of impedance occurring at different locations. Furthermore, it is also suitable for the system with distributed generations and dynamic loads.
引用
收藏
页码:987 / 996
页数:10
相关论文
共 50 条
  • [21] Fault Location Algorithm in Distribution Networks Considering Distributed Capacitive Current
    Li, Jiang
    Gao, Ming
    Liu, Bo
    Gao, Fan
    Chen, Jikai
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2021, 36 (05) : 2785 - 2793
  • [22] An automatic fault detection and location technique in low voltage distribution networks
    Navaneethan, S
    Soraghan, JJ
    Siew, WH
    Muirhead, R
    Livie, J
    [J]. PROCEEDINGS OF EMPD '98 - 1998 INTERNATIONAL CONFERENCE ON ENERGY MANAGEMENT AND POWER DELIVERY, VOLS 1 AND 2 AND SUPPLEMENT, 1998, : 732 - 736
  • [23] Accurate fault location method in distribution networks containing distributed generations
    Jamali, S.
    Talavat, V.
    [J]. Iranian Journal of Electrical and Computer Engineering, 2011, 10 (01): : 27 - 33
  • [24] Intelligent Fault Location Algorithms for Distributed Generation Distribution Networks: A Review
    GIRAL-RAMIREZ, Diego
    HERNANDEZ-SUAREZ, Cesar
    CORTES-TORRES, Jose
    [J]. PRZEGLAD ELEKTROTECHNICZNY, 2022, 98 (07): : 137 - 144
  • [25] Distributed generation location and capacity effect on voltage stability of distribution networks
    Hemdan, Nasser G. A.
    Kurrat, Michael
    [J]. 2008 ANNUAL IEEE STUDENT PAPER CONFERENCE, 2008, : 22 - 26
  • [26] New algorithm for location of single-line-to-ground fault on radial distribution network
    Jia, Wenchao
    Xu, Chengbin
    [J]. Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2000, 32 (02): : 118 - 120
  • [27] A novel superimposed voltage energy-based approach for single phase to ground fault detection and location in distribution networks
    Jalalt, Sajjad Miralizadeh
    Miralizadeh, Sepideh
    Talavat, Vahid
    Boalndi, Tohid Ghanizadeh
    [J]. IET GENERATION TRANSMISSION & DISTRIBUTION, 2023, 17 (18) : 4215 - 4233
  • [28] Fault location estimation method by considering measurement error for distribution networks
    Mokhlis, H.
    Awalin, L. J.
    Bakar, A. H. A.
    Illias, H. A.
    [J]. INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2014, 24 (09): : 1244 - 1262
  • [29] Impact of Resistive Superconducting Fault Current Limiter and Distributed Generation on Fault Location in Distribution Networks
    Guillen, Daniel
    Salas, Christian
    Trillaud, Frederic
    Castro, Luis M.
    Tiago Queiroz, Andre
    Goncalves Sotelo, Guilherme
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2020, 186
  • [30] Neural Networks Algorithm for Single Phase-Ground Fault Location with the Distributed Capacitor
    Kang Zhongjian
    Xu Li
    Gou Songbo
    Jin Huarong
    Li Ruisheng
    [J]. PROCEEDINGS OF THE 27TH CHINESE CONTROL CONFERENCE, VOL 6, 2008, : 8 - +