Use of 3T MRI and an unspoiled 3D fast gradient echo sequence for porcine knee cartilage volumetry: Preliminary findings

被引:0
|
作者
Cromer, Megan S. [1 ,2 ]
Foster, Sheryl L. [1 ,2 ]
Bourne, Roger M. [2 ]
Fransen, Marlene [3 ]
Fulton, Roger [2 ,4 ,5 ]
Wang, Shih-Chang [1 ,6 ]
机构
[1] Westmead Hosp, Dept Radiol, Sydney, NSW, Australia
[2] Univ Sydney, Fac Hlth Sci, Discipline Med Radiat Sci, Sydney, NSW 2006, Australia
[3] Univ Sydney, Fac Hlth Sci, Clin & Rehabil Sci Res Grp, Sydney, NSW 2006, Australia
[4] Westmead Hosp, Dept Med Phys, Sydney, NSW, Australia
[5] Univ Sydney, Sch Phys, Sydney, NSW 2006, Australia
[6] Sydney Med Sch, Discipline Imaging, Sydney, NSW, Australia
关键词
3T; cartilage quantification; magnetic resonance imaging; porcine knee; JOINT SPACE WIDTH; ARTICULAR-CARTILAGE; QUANTITATIVE ASSESSMENT; OSTEOARTHRITIS; PRECISION; REPRODUCIBILITY; ACCURACY; BONE; MORPHOLOGY;
D O I
10.1002/jmri.23898
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To assess the utility of knee cartilage volumetry using an unspoiled fat-suppressed 3D fast gradient echo (FGRE) sequence at 3T. Materials and Methods Sagittal magnetic resonance (MR) images were obtained with an unspoiled fat-suppressed 3D FGRE sequence in eight porcine knees. Manual segmentation was used to derive the cartilage volume. This volume was compared to a volume measurement of cartilage scraping specimens obtained by water displacement. Imaging was repeated five times in four of the knees to assess interscan volume measurement reproducibility and calculate precision error. A single 3D dataset was manually segmented five times at weekly intervals to assess intraobserver volume measurement reproducibility. Results Total cartilage volume obtained from MRI and water displacement correlated well (r = 0.75). The interscan reproducibility of total volume measurements, expressed as the coefficient of variation (CV), was 4.2%, and the precision error (root mean square [RMS] CV) was 4.1%. The CV of intraobserver estimates of total cartilage volume by MRI was 3.6%. Conclusion Interscan reproducibility of quantification of total cartilage volume and reproducibility of the manual segmentation technique were both high (>95%). Accurate and reproducible cartilage volumetry can be obtained by using a clinical unspoiled fat-suppressed 3D FGRE acquired at 3T MRI. J. Magn. Reson. Imaging 2013;38:245-250. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:245 / 250
页数:6
相关论文
共 50 条
  • [1] MRI of the cervical spine with 3D gradient echo sequence at 3 T: initial experience
    Xiao, L.
    Siu, C. W. J.
    Yeung, K.
    Leung, A.
    Yuen, M. K.
    Wong, Y. C.
    CLINICAL RADIOLOGY, 2015, 70 (09) : 926 - 931
  • [2] Evaluation of optimised 3D turbo spin echo and gradient echo MR pulse sequences of the knee at 3T and 1.5T
    Abdulaal, O. M.
    Rainford, L.
    MacMahon, P. J.
    Kenny, P.
    Carty, F.
    Galligan, M.
    Cradock, A.
    Alhazmi, F. H.
    McGee, A.
    RADIOGRAPHY, 2021, 27 (02) : 389 - 397
  • [3] Knee osteochondral junction imaging using a fast 3D T1-weighted ultrashort echo time cones sequence at 3T
    Cai, Zhenyu
    Wei, Zhao
    Wu, Mei
    Jerban, Saeed
    Jang, Hyungseok
    Li, Shaolin
    Yuan, Xuchun
    Ma, Ya-Jun
    MAGNETIC RESONANCE IMAGING, 2020, 73 : 76 - 83
  • [4] 3D gradient echo snapshot CEST MRI with low power saturation for human studies at 3T
    Deshmane, Anagha
    Zaiss, Moritz
    Lindig, Tobias
    Herz, Kai
    Schuppert, Mark
    Gandhi, Chirayu
    Bender, Benjamin
    Ernemann, Ulrike
    Scheffler, Klaus
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (04) : 2412 - 2423
  • [5] Assessment of knee cartilage using accelerated 3 T MRI: Evaluation of an isotropic 3D fast spin-echo sequence (CUBE) with compressed sensing technique
    Willaume, Thibault
    Ehlinger, Matthieu
    Favreau, Henri
    Weingertner, Noelle
    Zorn, Pierre-Emmanuel
    Dillenseger, Jean-Philippe
    Koch, Guillaume
    Velten, Michel
    Bierry, Guillaume
    MAGNETIC RESONANCE IMAGING, 2025, 117
  • [6] A 3D Deep Neural Network for Liver Volumetry in 3T Contrast-Enhanced MRI
    Winther, Hinrich
    Hundt, Christian
    Ringe, Kristina Imeen
    Wacker, Frank K.
    Schmidt, Bertil
    Juergens, Julian
    Haimerl, Michael
    Beyer, Lukas Philipp
    Stroszczynski, Christian
    Wiggermann, Philipp
    Verloh, Niklas
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2021, 193 (03): : 305 - 314
  • [7] Preliminary use of a double-echo pulse sequence with 3D ultrashort echo time in the MRI of bones and joints
    Ma, Liheng
    Meng, Quanfei
    Chen, Yingming
    Zhang, Zhaohui
    Sun, Haixing
    Deng, Demao
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2013, 5 (05) : 1471 - 1475
  • [8] 3T MRI Scanner Magnetic Gradient Mapping using a 3D Hall Probe
    Schell, J. -B.
    Kammerer, J. -B.
    Hebrard, L.
    Gounot, D.
    Breton, E.
    Cuvillon, L.
    de Mathelin, M.
    2012 IEEE SENSORS PROCEEDINGS, 2012, : 2038 - 2041
  • [9] IDEAL 3D spoiled gradient echo of the articular cartilage of the knee on 3.0T MRI: a comparison with conventional 3.0T fast spin-echo T2 fat saturation image
    Han, Chul Hee
    Park, Hee Jin
    Lee, So Yeon
    Chung, Eun Chul
    Choi, Seon Hyeong
    Yun, Ji Sup
    Rho, Myung Ho
    ACTA RADIOLOGICA, 2015, 56 (12) : 1479 - 1486
  • [10] MRI OF THE KNEE-JOINT WITH A 3-D GRADIENT ECHO SEQUENCE - EQUIVALENT TO DIAGNOSTIC ARTHROSCOPY
    GLUCKERT, K
    KLADNY, B
    BLANKSCHAL, A
    HOFMANN, G
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1992, 112 (01) : 5 - 14