MRI of the cervical spine with 3D gradient echo sequence at 3 T: initial experience

被引:12
|
作者
Xiao, L. [1 ]
Siu, C. W. J. [2 ]
Yeung, K. [2 ]
Leung, A. [2 ]
Yuen, M. K. [2 ]
Wong, Y. C. [2 ]
机构
[1] TuenMun Hosp, Dept Oncol, HA, Hong Kong, Hong Kong, Peoples R China
[2] TuenMun Hosp, Dept Radiol, HA, Hong Kong, Hong Kong, Peoples R China
关键词
MULTIPLE-SCLEROSIS; MAGNETIZATION-TRANSFER; RECALLED-ECHO; IMAGE QUALITY; CORD; CONTRAST; LESIONS; BRAIN; PULSE;
D O I
10.1016/j.crad.2015.05.012
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: The aim of this study was to compare three-dimensional (3D) high resolution T2*-weighted gradient echo (3D FFE) magnetic resonance (MR) sequence with conventional 2D T2-weighted turbo spin echo (TSE) MR sequence for imaging of the cervical spine, especially to assess the detectability of the internal anatomy of the cervical spinal cord, i.e. to distinguish the grey and white matter. METHODS: Fifteen volunteers were examined at 3.0T MR unit. Signal-to-noise (SNR), contrast-to-noise (CNR) and image homogeneity were evaluated. In the visual analysis, the visibility of anatomical structures of the cervical spine and artifacts were assessed. The nonparametric method of paired sample t-test was adopted to evaluate the differences between the sequences. RESULTS: The 3D FFE sequence provided better results for CNR, cerebrospinal fluid (CSF) versus white matter, grey matter, disk and bone. Moreover, it yielded good results for the CNR grey matter versus white matter. The butterfly-shaped "H" is clearly displayed in the 3D FFE sequence. The statistical analysis revealed the statistically significant difference between the 2D TSE and 3D FFE sequences for the contrast of CSF versus spinal cord (both grey matter and white matter). CONCLUSION: The 3D FFE sequence in MR imaging of the cervical spinal cord is superior in delineation of spinal cord anatomical structures compared to 2D TSE sequence. (C) 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:926 / 931
页数:6
相关论文
共 50 条
  • [1] Contrast-Enhanced 3D Spin Echo T1-Weighted Sequence Outperforms 3D Gradient Echo T1-Weighted Sequence for the Detection of Multiple Sclerosis Lesions on 3.0 T Brain MRI
    de Panafieu, Ariane
    Lecler, Augustin
    Goujon, Adrien
    Krystal, Sidney
    Gueguen, Antoine
    Sadik, Jean-Claude
    Savatovsky, Julien
    Duron, Loic
    INVESTIGATIVE RADIOLOGY, 2023, 58 (05) : 314 - 319
  • [2] Use of 3T MRI and an unspoiled 3D fast gradient echo sequence for porcine knee cartilage volumetry: Preliminary findings
    Cromer, Megan S.
    Foster, Sheryl L.
    Bourne, Roger M.
    Fransen, Marlene
    Fulton, Roger
    Wang, Shih-Chang
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 38 (01) : 245 - 250
  • [3] 3D MRI of the Spine
    Sahr, Meghan
    Tan, Ek Tsoon
    Sneag, Darryl B.
    SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2021, 25 (03) : 433 - 440
  • [4] Diffusion-prepared 3D gradient spin-echo sequence for improved oscillating gradient diffusion MRI
    Wu, Dan
    Liu, Dapeng
    Hsu, Yi-Cheng
    Li, Haotian
    Sun, Yi
    Qin, Qin
    Zhang, Yi
    MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (01) : 92 - 102
  • [5] 3D sagittal T2 weighted fast spin echo imaging of the cervical spine with axial reformations: Comparison to gradient-echo sequences
    Jones, KC
    Johnson, CE
    Destian, S
    Kagetsu, NJ
    RADIOLOGY, 1998, 209P : 202 - 202
  • [6] Gel dosimetry by MRI using 3D gradient echo sequences
    Haacke, M
    Low, D
    Feng, L
    Herigault, G
    Islam, K
    Gurleyik, K
    MEDICAL PHYSICS, 2002, 29 (06) : 1206 - 1206
  • [7] T1ρ-prepared balanced gradient echo for rapid 3D t1ρ MRI
    Witschey, Walter R. T.
    Borthakur, Arijitt
    Elliott, Mark A.
    Fenty, Matthew
    Sochor, Matthew A.
    Wang, Chenyang
    Reddy, Ravinder
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (03) : 744 - 754
  • [8] 3D gradient echo snapshot CEST MRI with low power saturation for human studies at 3T
    Deshmane, Anagha
    Zaiss, Moritz
    Lindig, Tobias
    Herz, Kai
    Schuppert, Mark
    Gandhi, Chirayu
    Bender, Benjamin
    Ernemann, Ulrike
    Scheffler, Klaus
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (04) : 2412 - 2423
  • [9] A 3D MRI sequence for computer assisted surgery of the lumbar spine
    Hoad, CL
    Martel, AL
    Kerslake, R
    Grevitt, M
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (08): : N213 - N220
  • [10] "Value of 3D STIR Gated MRI Sequence in Cardiac and Chest Imaging with 3T MRI": Initial Experiences
    Kandasamy, Geetha
    Peter, S. Babu
    Priya, R. Bharathi
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2019, 13 (01) : TC6 - TC9