MRI of the cervical spine with 3D gradient echo sequence at 3 T: initial experience

被引:12
|
作者
Xiao, L. [1 ]
Siu, C. W. J. [2 ]
Yeung, K. [2 ]
Leung, A. [2 ]
Yuen, M. K. [2 ]
Wong, Y. C. [2 ]
机构
[1] TuenMun Hosp, Dept Oncol, HA, Hong Kong, Hong Kong, Peoples R China
[2] TuenMun Hosp, Dept Radiol, HA, Hong Kong, Hong Kong, Peoples R China
关键词
MULTIPLE-SCLEROSIS; MAGNETIZATION-TRANSFER; RECALLED-ECHO; IMAGE QUALITY; CORD; CONTRAST; LESIONS; BRAIN; PULSE;
D O I
10.1016/j.crad.2015.05.012
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: The aim of this study was to compare three-dimensional (3D) high resolution T2*-weighted gradient echo (3D FFE) magnetic resonance (MR) sequence with conventional 2D T2-weighted turbo spin echo (TSE) MR sequence for imaging of the cervical spine, especially to assess the detectability of the internal anatomy of the cervical spinal cord, i.e. to distinguish the grey and white matter. METHODS: Fifteen volunteers were examined at 3.0T MR unit. Signal-to-noise (SNR), contrast-to-noise (CNR) and image homogeneity were evaluated. In the visual analysis, the visibility of anatomical structures of the cervical spine and artifacts were assessed. The nonparametric method of paired sample t-test was adopted to evaluate the differences between the sequences. RESULTS: The 3D FFE sequence provided better results for CNR, cerebrospinal fluid (CSF) versus white matter, grey matter, disk and bone. Moreover, it yielded good results for the CNR grey matter versus white matter. The butterfly-shaped "H" is clearly displayed in the 3D FFE sequence. The statistical analysis revealed the statistically significant difference between the 2D TSE and 3D FFE sequences for the contrast of CSF versus spinal cord (both grey matter and white matter). CONCLUSION: The 3D FFE sequence in MR imaging of the cervical spinal cord is superior in delineation of spinal cord anatomical structures compared to 2D TSE sequence. (C) 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:926 / 931
页数:6
相关论文
共 50 条
  • [21] 3D imaging of the whole spine at 3T compared to 1.5T: Initial experiences
    Rodegerdts, EA
    Boss, A
    Riemarzik, K
    Lichy, M
    Schick, F
    Claussen, CD
    Schlemmer, HP
    ACTA RADIOLOGICA, 2006, 47 (05) : 488 - 493
  • [22] Free-Breathing 3D T1-Weighted Gradient-Echo Sequence With Radial Data Sampling in Abdominal MRI: Preliminary Observations
    Azevedo, Rafael M.
    de Campos, Rafael O. P.
    Ramalho, Miguel
    Heredia, Vasco
    Dale, Brian M.
    Semelka, Richard C.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (03) : 650 - 657
  • [23] Improved detection of focal cortical dysplasia using a novel 3D imaging sequence: Edge-Enhancing Gradient Echo (3D-EDGE) MRI
    Middlebrooks, Erik H.
    Lin, Chen
    Westerhold, Erin
    Okromelidze, Lela
    Vibhute, Prasanna
    Grewal, Sanjeet S.
    Gupta, Vivek
    NEUROIMAGE-CLINICAL, 2020, 28
  • [24] Advantages of a T1-Weighted Gradient-Recalled Echo (GRE) Sequence With a Radial 3D Sampling Approach Versus 2D Turbo Spin-Echo and Cartesian 3D GRE Sequences in Head and Neck MRI
    Fahlenkamp, Ute Lina
    Siepmann, Stefan
    Fehrenbach, Uli
    Thieme, Nadine
    Doellinger, Felix
    Hamm, Bernd
    Denecke, Timm
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2020, 214 (04) : 747 - 752
  • [25] Evaluation of axial gradient Echo spiral MRI of the spine at 1.5 T
    Robison, Ryan K. K.
    Cornejo, Patricia
    Kuwabara, Michael
    Ooi, Melvyn B. B.
    Temkit, Hamy
    Miller, Jeffrey H. H.
    MAGNETIC RESONANCE IMAGING, 2022, 89 : 24 - 32
  • [26] Short echo-time 3D radial gradient-echo MRI using concurrent dephasing and excitation
    Park, Jang-Yeon
    Moeller, Steen
    Goerke, Ute
    Auerbach, Edward
    Chamberlain, Ryan
    Ellermann, Jutta
    Garwood, Michael
    MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (02) : 428 - 436
  • [27] Imaging arterial and venous vessels using Iron Dextran enhanced multi-echo 3D gradient echo MRI at 7T
    Li, Yinghao
    Li, Wei
    Paez, Adrian
    Cao, Di
    Sun, Yuanqi
    Gu, Chunming
    Zhang, Kaihua
    Miao, Xinyuan
    Liu, Peiying
    Li, Wenbo
    Pillai, Jay
    Lu, Hanzhang
    van Zijl, Peter C. M.
    Earley, Christopher
    Li, Xu
    Hua, Jun
    NMR IN BIOMEDICINE, 2024, 37 (12)
  • [28] MRI OF THE CERVICAL-SPINE - A COMPARISON OF SPIN-ECHO WITH A RAPID T2-DEPENDENT GRADIENT ECHO TECHNIQUE - FISP
    STACK, J
    REDMOND, O
    MACMANAMON, P
    KIRBY, B
    ENNIS, JT
    CLINICAL RADIOLOGY, 1988, 39 (06) : 677 - 677
  • [29] 3D zero-echo time and 3D T1-weighted gradient-echo MRI sequences as an alternative to CT for the evaluation of the lumbar facet joints and lumbosacral transitional vertebrae
    Kaniewska, Malwina
    Kuhn, Daniel
    Deininger-Czermak, Eva
    Wolharn, Lucas
    Finkenstaedt, Tim
    Guggenberger, Roman
    ACTA RADIOLOGICA, 2023, 64 (06) : 2137 - 2144
  • [30] B1 Mapping of Short T2* Spins Using a 3D Radial Gradient Echo Sequence
    Kobayashi, Naoharu
    Garwood, Michael
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (05) : 1689 - 1699