Use of 3T MRI and an unspoiled 3D fast gradient echo sequence for porcine knee cartilage volumetry: Preliminary findings

被引:0
|
作者
Cromer, Megan S. [1 ,2 ]
Foster, Sheryl L. [1 ,2 ]
Bourne, Roger M. [2 ]
Fransen, Marlene [3 ]
Fulton, Roger [2 ,4 ,5 ]
Wang, Shih-Chang [1 ,6 ]
机构
[1] Westmead Hosp, Dept Radiol, Sydney, NSW, Australia
[2] Univ Sydney, Fac Hlth Sci, Discipline Med Radiat Sci, Sydney, NSW 2006, Australia
[3] Univ Sydney, Fac Hlth Sci, Clin & Rehabil Sci Res Grp, Sydney, NSW 2006, Australia
[4] Westmead Hosp, Dept Med Phys, Sydney, NSW, Australia
[5] Univ Sydney, Sch Phys, Sydney, NSW 2006, Australia
[6] Sydney Med Sch, Discipline Imaging, Sydney, NSW, Australia
关键词
3T; cartilage quantification; magnetic resonance imaging; porcine knee; JOINT SPACE WIDTH; ARTICULAR-CARTILAGE; QUANTITATIVE ASSESSMENT; OSTEOARTHRITIS; PRECISION; REPRODUCIBILITY; ACCURACY; BONE; MORPHOLOGY;
D O I
10.1002/jmri.23898
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To assess the utility of knee cartilage volumetry using an unspoiled fat-suppressed 3D fast gradient echo (FGRE) sequence at 3T. Materials and Methods Sagittal magnetic resonance (MR) images were obtained with an unspoiled fat-suppressed 3D FGRE sequence in eight porcine knees. Manual segmentation was used to derive the cartilage volume. This volume was compared to a volume measurement of cartilage scraping specimens obtained by water displacement. Imaging was repeated five times in four of the knees to assess interscan volume measurement reproducibility and calculate precision error. A single 3D dataset was manually segmented five times at weekly intervals to assess intraobserver volume measurement reproducibility. Results Total cartilage volume obtained from MRI and water displacement correlated well (r = 0.75). The interscan reproducibility of total volume measurements, expressed as the coefficient of variation (CV), was 4.2%, and the precision error (root mean square [RMS] CV) was 4.1%. The CV of intraobserver estimates of total cartilage volume by MRI was 3.6%. Conclusion Interscan reproducibility of quantification of total cartilage volume and reproducibility of the manual segmentation technique were both high (>95%). Accurate and reproducible cartilage volumetry can be obtained by using a clinical unspoiled fat-suppressed 3D FGRE acquired at 3T MRI. J. Magn. Reson. Imaging 2013;38:245-250. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:245 / 250
页数:6
相关论文
共 50 条
  • [21] T2 MRI at 3T of cartilage and menisci in patients with hyperuricemia: initial findings
    Ningfan Hu
    Jiangtao Zhu
    Xiaoyun Liang
    Yajuan Wang
    Jian Guan
    Wanxin Wen
    Ligong Wang
    Skeletal Radiology, 2022, 51 : 607 - 618
  • [22] Cartilage imaging of the knee at low field strength (0.5T): Use of a 3-point Dixon gradient-echo sequence
    Neumann, GM
    Rosato, J
    Kacher, DF
    Splitthoff, AJ
    Li, G
    Lang, PK
    RADIOLOGY, 2002, 225 : 329 - 329
  • [23] ISOTROPIC THREE-DIMENSIONAL T2 MAPPING OF KNEE CARTILAGE WITH T2-PREPARED SEGMENTED GRADIENT ECHO AT 3T
    Colotti, R.
    Omoumi, P.
    van Heeswijk, R. B.
    OSTEOARTHRITIS AND CARTILAGE, 2016, 24 : S300 - S301
  • [24] Contrast-Enhanced 3D Spin Echo T1-Weighted Sequence Outperforms 3D Gradient Echo T1-Weighted Sequence for the Detection of Multiple Sclerosis Lesions on 3.0 T Brain MRI
    de Panafieu, Ariane
    Lecler, Augustin
    Goujon, Adrien
    Krystal, Sidney
    Gueguen, Antoine
    Sadik, Jean-Claude
    Savatovsky, Julien
    Duron, Loic
    INVESTIGATIVE RADIOLOGY, 2023, 58 (05) : 314 - 319
  • [25] T2 MRI at 3T of cartilage and menisci in patients with hyperuricemia: initial findings
    Hu, Ningfan
    Zhu, Jiangtao
    Liang, Xiaoyun
    Wang, Yajuan
    Guan, Jian
    Wen, Wanxin
    Wang, Ligong
    SKELETAL RADIOLOGY, 2022, 51 (03) : 607 - 618
  • [26] Utility of the variable flip angle 3D fast-spin echo (isoFSE) sequence on 3T MR for diagnosing vertebrobasilar artery dissection
    Ogawa M.
    Omata S.
    Kan H.
    Arai N.
    Asai M.
    Urano M.
    Shibamoto Y.
    Radiological Physics and Technology, 2018, 11 (2) : 228 - 234
  • [27] Hypoglossal Nerve Lesions: The Role of a 3D IR-Prepped Fast SPGR High-Resolution 3T MRI Sequence
    Geng, Chengjun
    Lu, Zehua
    Xuan, Lulu
    Yin, Huikang
    Yang, Xiaoliang
    Yang, Liyue
    Xia, Xiaoliang
    Chu, Wei
    JOURNAL OF NEUROIMAGING, 2021, 31 (01) : 180 - 185
  • [28] Topographic deformation patterns of knee cartilage after exercises with high knee flexion: an in vivo 3D MRI study using voxel-based analysis at 3T
    Annie Horng
    J. G. Raya
    M. Stockinger
    M. Notohamiprodjo
    M. Pietschmann
    U. Hoehne-Hueckstaedt
    U. Glitsch
    R. Ellegast
    K. G. Hering
    C. Glaser
    European Radiology, 2015, 25 : 1731 - 1741
  • [29] Topographic deformation patterns of knee cartilage after exercises with high knee flexion: an in vivo 3D MRI study using voxel-based analysis at 3T
    Horng, Annie
    Raya, J. G.
    Stockinger, M.
    Notohamiprodjo, M.
    Pietschmann, M.
    Hoehne-Hueckstaedt, U.
    Glitsch, U.
    Ellegast, R.
    Hering, K. G.
    Glaser, C.
    EUROPEAN RADIOLOGY, 2015, 25 (06) : 1731 - 1741
  • [30] Free-Breathing 3D T1-Weighted Gradient-Echo Sequence With Radial Data Sampling in Abdominal MRI: Preliminary Observations
    Azevedo, Rafael M.
    de Campos, Rafael O. P.
    Ramalho, Miguel
    Heredia, Vasco
    Dale, Brian M.
    Semelka, Richard C.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (03) : 650 - 657