The key incident monitoring and management system - history and role in quality improvement

被引:18
|
作者
Badrick, Tony [1 ]
Gay, Stephanie [1 ]
Mackay, Mark [1 ]
Sikaris, Ken [2 ]
机构
[1] RCPAQAP, Sydney, NSW, Australia
[2] Melbourne Pathol, Melbourne, Vic, Australia
关键词
Failure Mode Effects Analysis (FMEA); post-analytical error; pre-analytical error; Quality Indicators; LABORATORY MEDICINE; CLINICAL LABORATORIES; INDICATORS; EXPERIENCE; PROGRAM; PHASE;
D O I
10.1515/cclm-2017-0219
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: The determination of reliable, practical Quality Indicators (QIs) from presentation of the patient with a pathology request form through to the clinician receiving the report (the Total Testing Process or TTP) is a key step in identifying areas where improvement is necessary in laboratories. Methods: The Australasian QIs programme Key Incident Monitoring and Management System (KIMMS) began in 2008. It records incidents (process defects) and episodes (occasions at which incidents may occur) to calculate incident rates. KIMMS also uses the Failure Mode Effects Analysis (FMEA) to assign quantified risk to each incident type. The system defines risk as incident frequency multiplied by both a harm rating (on a 1-10 scale) and detection difficulty score (also a 1-10 scale). Results: Between 2008 and 2016, laboratories participating rose from 22 to 69. Episodes rose from 13.2 to 43.4 million; incidents rose from 114,082 to 756,432. We attribute the rise in incident rate from 0.86% to 1.75% to increased monitoring. Haemolysis shows the highest incidence (22.6% of total incidents) and the highest risk (26.68% of total risk). "Sample is suspected to be from the wrong patient" has the second lowest frequency, but receives the highest harm rating (10/10) and detection difficulty score (10/10), so it is calculated to be the 8th highest risk (2.92%). Similarly, retracted (incorrect) reports QI has the 10th highest frequency (3.9%) but the harm/difficulty calculation confers the second highest risk (11.17%). Conclusions: TTP incident rates are generally low (less than 2% of observed episodes), however, incident risks, their frequencies multiplied by both ratings of harm and discovery difficulty scores, concentrate improvement attention and resources on the monitored incident types most important to manage.
引用
收藏
页码:264 / 272
页数:9
相关论文
共 50 条
  • [31] VISIBILITY - THE KEY TO QUALITY IMPROVEMENT
    ROBERTSON, S
    IEEE SOFTWARE, 1995, 12 (04) : 95 - 97
  • [32] Nursing: Key to Quality Improvement
    Lacey, Susan R.
    Cox, Karen S.
    PEDIATRIC CLINICS OF NORTH AMERICA, 2009, 56 (04) : 975 - +
  • [33] Tracking and Controlling Everything that Affects Quality is the Key to a Quality Management System
    Hull, Carl
    Wray, Bruce
    Winslow, Ford
    Vilicich, Mark
    COMBINATORIAL CHEMISTRY & HIGH THROUGHPUT SCREENING, 2011, 14 (09) : 772 - 780
  • [34] CREATING THE QUALITY MANAGEMENT-SYSTEM - THE ROLE OF THE MANAGER IN QUALITY MANAGEMENT
    NORTH, C
    TAPPI JOURNAL, 1990, 73 (03): : 383 - 384
  • [35] CREATING THE QUALITY MANAGEMENT-SYSTEM - THE ROLE OF TEAMS IN QUALITY MANAGEMENT
    HUETCOX, GD
    TAPPI JOURNAL, 1990, 73 (01): : 249 - 250
  • [36] Impact of the quality of management on the general improvement of the healthcare system
    Brzostek, Tomasz
    Domagala, Alicja
    TECHNOLOGY AND HEALTH CARE, 2019, 27 (01) : 107 - 110
  • [37] IDEA MANAGEMENT SYSTEM - AN ESSENCIAL COMPONENT IN THE IMPROVEMENT OF QUALITY
    Santos, Gilberto
    Afonseca, Jose
    Lopes, Nuno
    Doiro, Manuel
    Rui Alves, M.
    M2D2015: PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON MECHANICS AND MATERIALS IN DESIGN, 2015, : 2091 - 2092
  • [39] System thinking for quality management and continuous improvement in mining
    Vallée, M
    CIM BULLETIN, 2003, 96 (1068): : 48 - 58
  • [40] Energy Management System For Microgrid With Power Quality Improvement
    Borase, Prajakta B.
    Akolkar, Sonali M.
    2017 INTERNATIONAL CONFERENCE ON MICROELECTRONIC DEVICES, CIRCUITS AND SYSTEMS (ICMDCS), 2017,