Application of a semi-automated dicentric scoring system in triage and monitoring occupational radiation exposure

被引:0
|
作者
Lee, Younghyun [1 ,2 ]
Kim, Seung Hyun [1 ]
Lee, Yang Hee [1 ]
Yang, Su San [1 ]
Yoon, Hyo Jin [1 ]
Wilkins, Ruth C. [3 ]
Jang, Seongjae [1 ]
机构
[1] Korea Inst Radiol & Med Sci, Natl Radiat Emergency Med Ctr, Lab Biol Dosimetry, Seoul, South Korea
[2] Soonchunhyang Univ, Coll Med Sci, Dept Biomed Lab Sci, Asan, South Korea
[3] Hlth Canada, Consumer & Clin Radiat Protect Bur, Ottawa, ON, Canada
关键词
dicentric chromosome assay; radiation biodosimetry; semi-automated scoring; radiological emergencies; occupational radiation exposure; BIOLOGICAL DOSIMETRY; RETROSPECTIVE BIODOSIMETRY; CHROMOSOME ANALYSIS; VALIDATION; ASSAY;
D O I
10.3389/fpubh.2022.1002501
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
The dicentric chromosome assay (DCA) is considered the gold standard for radiation biodosimetry, but it is limited by its long dicentric scoring time and need for skilled scorers. The automation of scoring dicentrics has been considered a strategy to overcome the constraints of DCA. However, the studies on automated scoring methods are limited compared to those on conventional manual DCA. Our study aims to assess the performance of a semi-automated scoring method for DCA using ex vivo and in vivo irradiated samples. Dose estimations of 39 blind samples irradiated ex vivo and 35 industrial radiographers occupationally exposed in vivo were estimated using the manual and semi-automated scoring methods and subsequently compared. The semi-automated scoring method, which removed the false positives of automated scoring using the dicentric chromosome (DC) scoring algorithm, had an accuracy of 94.9% in the ex vivo irradiated samples. It also had more than 90% accuracy, sensitivity, and specificity to distinguish binary dose categories reflecting clinical, diagnostic, and epidemiological significance. These data were comparable to those of manual DCA. Moreover, Cohen's kappa statistic and McNemar's test showed a substantial agreement between the two methods for categorizing in vivo samples into never and ever radiation exposure. There was also a significant correlation between the two methods. Despite of comparable results with two methods, lower sensitivity of semi-automated scoring method could be limited to assess various radiation exposures. Taken together, our findings show the semi-automated scoring method can provide accurate dose estimation rapidly, and can be useful as an alternative to manual DCA for biodosimetry in large-scale accidents or cases to monitor radiation exposure of radiation workers.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] A semi-automated system for quantitative analysis of Meliodogyne reproduction
    Kilcrease, J.
    Solano, F.
    Rascon, A.
    Hanson, S.
    [J]. PHYTOPATHOLOGY, 2010, 100 (06) : S62 - S62
  • [42] OntoloBridge: A semi-automated ontology update request system
    Turner, John
    Clark, Alex
    McGinty, Hande
    Bunin, Barry
    Schurer, Stephan
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2018, 256
  • [43] Semi-automated system of silicoflagellate skeleton by personal computer
    Tsutsui, H
    Nishiwaki, N
    Nishida, S
    [J]. GIS and Spatial Analysis, Vol 1and 2, 2005, : 1242 - 1247
  • [44] Design calculations in the development of a semi-automated weaving system
    Elamvazuthi, I
    Nidzam, M
    Sabilan, S
    Kamaruddin, S
    Azmi, MS
    Nazri, A
    [J]. SENSORS: ASIASENSE 2003 - ASIAN CONFERENCE ON SENSORS, 2003, : 347 - 351
  • [45] Semi-automated system for measurement of nuchal translucency thickness
    Moratalla, J.
    Pintoffl, K.
    Minekawa, R.
    Lachmann, R.
    Wright, D.
    Nicolaides, K. H.
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2010, 36 (04) : 412 - 416
  • [46] Trauma Pod: a semi-automated telerobotic surgical system
    Garcia, Pablo
    Rosen, Jacob
    Kapoor, Chetan
    Noakes, Mark
    Elbert, Greg
    Treat, Michael
    Ganous, Tim
    Hanson, Matt
    Manak, Joe
    Hasser, Chris
    Rohler, David
    Satava, Richard
    [J]. INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2009, 5 (02): : 136 - 146
  • [47] Evaluation of a semi-automated clinical decision support system
    Dahmke, H.
    Fiumefreddo, R.
    Zaugg, C.
    [J]. INTERNATIONAL JOURNAL OF CLINICAL PHARMACY, 2022, 44 (06) : 1472 - 1472
  • [48] Remote maintenance system for semi-automated manufacturing machines
    Sangregorio, P.
    Cologni, A. L.
    Owen, F. C.
    Previdi, F.
    [J]. 2015 IEEE 1ST INTERNATIONAL FORUM ON RESEARCH AND TECHNOLOGIES FOR SOCIETY AND INDUSTRY (RTSI 2015) PROCEEDINGS, 2015,
  • [49] A semi-automated system for the characterization of NLC accelerating structures
    Hanna, SM
    Bowden, GB
    Hoag, HA
    Loewen, R
    Vlieks, AE
    Wang, JW
    [J]. PROCEEDINGS OF THE 1995 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-5, 1996, : 1108 - 1110
  • [50] A COMPACT MICROWAVE SYSTEM FOR RAPID, SEMI-AUTOMATED RADIOSYNTHESES
    Olma, S.
    Lambert, J.
    Barnhardt, E.
    Liu, K.
    Shen, C.
    van Dam, R.
    [J]. JOURNAL OF LABELLED COMPOUNDS & RADIOPHARMACEUTICALS, 2009, 52 : S509 - S509