Optimal cannula positioning of HeartMate 3 left ventricular assist device

被引:4
|
作者
Imamura, Teruhiko [1 ,2 ]
Narang, Nikhil [1 ]
Nitta, Daisuke [1 ]
Fujino, Takeo [1 ]
Nguyen, Ann [1 ]
Kim, Gene [1 ]
Raikhelkar, Jayant [3 ]
Rodgers, Daniel [1 ]
Ota, Takeyoshi [4 ]
Jeevanandam, Valluvan [4 ]
Sayer, Gabriel [3 ]
Uriel, Nir [3 ]
机构
[1] Univ Chicago, Med Ctr, Div Cardiol, Chicago, IL 60637 USA
[2] Univ Toyama, Dept Internal Med 2, 2630 Sugitani Toyama, Toyama 9300194, Japan
[3] Columbia Univ, Div Cardiol, Med Ctr, New York, NY USA
[4] Univ Chicago, Med Ctr, Dept Surg, Chicago, IL 60637 USA
关键词
cannula position; hemodynamics; left ventricular assist device; right heart failure; unloading; SUPPORT; GUIDELINES; FAILURE; SOCIETY;
D O I
10.1111/aor.13755
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Cannula position in HeartMate II and HeartWare left ventricular assist devices (LVADs) is associated with clinical outcome. This study aimed to investigate the clinical implication of the device positioning in HeartMate 3 LVAD cohort. Consecutive patients who underwent HeartMate 3 LVAD implantation were followed for one year from index discharge. At index discharge, chest X-ray parameters were measured: (a) cannula coronal angle, (b) height of pump bottom, (c) cannula sagittal angle, and (d) cannula lumen area. The association of each measurement of cannula position with one-year clinical outcomes was investigated. Sixty-four HeartMate 3 LVAD patients (58 years old, 64% male) were enrolled. In the multivariable Cox regression model, the cannula coronal angle was a significant predictor of death or heart failure readmission (hazard ratio 1.27 [1.01-1.60],P= .045). Patients with a cannula coronal angle <= 28 degrees had lower central venous pressure (P= .030), lower pulmonary capillary wedge pressure (P= .027), and smaller left ventricular size (P= .019) compared to those with the angle >28 degrees. Right ventricular size and parameters of right ventricular function were also better in the narrow angle group, as was one-year cumulative incidence of death or heart failure readmission (10% vs. 50%,P= .008). Narrow cannula coronal angle in patients with HeartMate 3 LVADs was associated with improved cardiac unloading and lower incidence of death or heart failure readmission. Larger studies to confirm the implication of optimal device positioning are warranted.
引用
收藏
页码:E509 / E519
页数:11
相关论文
共 50 条
  • [1] Optimal Cannula Positioning of Heart Mate 3 Left Ventricular Assist Device
    Imamura, T.
    Nitta, D.
    Fujino, T.
    Nguyen, A.
    Narang, N.
    Chung, B.
    Holzhauser, L.
    Kim, G.
    Raikhelkar, J.
    Rodgers, D.
    Ota, T.
    Jeevanandam, V.
    Burkhoff, D.
    Sayer, G.
    Uriel, N.
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2020, 39 (04): : S425 - S426
  • [2] Technique for Insertion of HeartMate II Left Ventricular Assist Device Inflow Cannula
    Soleimani, Behzad
    Stephenson, Edward R.
    Pae, Walter E.
    [J]. ANNALS OF THORACIC SURGERY, 2011, 91 (06): : 2001 - 2002
  • [3] Device exchange from HeartMate II to HeartMate 3 left ventricular assist device
    Takeda, Koji
    Takayama, Hiroo
    Sanchez, Joseph
    Cevasco, Marisa
    Yuzefpolskaya, Melana
    Colombo, Paolo C.
    Naka, Yoshifumi
    [J]. INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2019, 29 (03) : 430 - 433
  • [4] Left Ventricular Assist Device Inflow Cannula Position May Contribute to the Development of HeartMate II Left Ventricular Assist Device Pump Thrombosis
    Bhama, Jay K.
    Bansal, Aditya
    [J]. OCHSNER JOURNAL, 2018, 18 (02): : 131 - 135
  • [5] Inflow Cannula Position as Predictor for Neurological Dysfunction in Patients with HeartMate 3 Left Ventricular Assist Device
    Schloeglhofer, T.
    Aigner, P.
    Migas, M.
    Beitzke, D.
    Wittmann, F.
    Riebandt, J.
    Wiedemann, D.
    Laufer, G.
    Moscato, F.
    Schima, H.
    Zimpfer, D.
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2020, 39 (04): : S97 - S98
  • [6] Exchange of a HeartMate II left ventricular assist device with a HeartMate 3 pump
    Hanke, Jasmin S.
    Haverich, Axel
    Schmitto, Jan D.
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2016, 35 (07): : 944 - 946
  • [7] Discontinuation of Aspirin in Heartmate 3 Left Ventricular Assist Device
    Lim, Hoong Sern
    Ranasinghe, Aaron
    Mascaro, Jorge
    Howell, Neil
    [J]. ASAIO JOURNAL, 2019, 65 (06) : 631 - 633
  • [8] Discontinuation of Aspirin in Heartmate 3 Left Ventricular Assist Device
    Lim, S.
    Ranasinghe, A.
    Howell, N.
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2018, 37 (04): : S72 - S72
  • [9] Recovery Plug for HeartMate 3 Left Ventricular Assist Device
    Mulzer, J.
    Potapov, E.
    Kaufmann, F.
    Mueller, M.
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2018, 37 (04): : S480 - S480
  • [10] Recovery plug for HeartMate 3 left ventricular assist device
    Mulzer, Johanna
    Faerber, Gloria
    Kaufmann, Friedrich
    Potapov, Evgenij V.
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2019, 157 (02): : E35 - E37