Optimal cannula positioning of HeartMate 3 left ventricular assist device

被引:4
|
作者
Imamura, Teruhiko [1 ,2 ]
Narang, Nikhil [1 ]
Nitta, Daisuke [1 ]
Fujino, Takeo [1 ]
Nguyen, Ann [1 ]
Kim, Gene [1 ]
Raikhelkar, Jayant [3 ]
Rodgers, Daniel [1 ]
Ota, Takeyoshi [4 ]
Jeevanandam, Valluvan [4 ]
Sayer, Gabriel [3 ]
Uriel, Nir [3 ]
机构
[1] Univ Chicago, Med Ctr, Div Cardiol, Chicago, IL 60637 USA
[2] Univ Toyama, Dept Internal Med 2, 2630 Sugitani Toyama, Toyama 9300194, Japan
[3] Columbia Univ, Div Cardiol, Med Ctr, New York, NY USA
[4] Univ Chicago, Med Ctr, Dept Surg, Chicago, IL 60637 USA
关键词
cannula position; hemodynamics; left ventricular assist device; right heart failure; unloading; SUPPORT; GUIDELINES; FAILURE; SOCIETY;
D O I
10.1111/aor.13755
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Cannula position in HeartMate II and HeartWare left ventricular assist devices (LVADs) is associated with clinical outcome. This study aimed to investigate the clinical implication of the device positioning in HeartMate 3 LVAD cohort. Consecutive patients who underwent HeartMate 3 LVAD implantation were followed for one year from index discharge. At index discharge, chest X-ray parameters were measured: (a) cannula coronal angle, (b) height of pump bottom, (c) cannula sagittal angle, and (d) cannula lumen area. The association of each measurement of cannula position with one-year clinical outcomes was investigated. Sixty-four HeartMate 3 LVAD patients (58 years old, 64% male) were enrolled. In the multivariable Cox regression model, the cannula coronal angle was a significant predictor of death or heart failure readmission (hazard ratio 1.27 [1.01-1.60],P= .045). Patients with a cannula coronal angle <= 28 degrees had lower central venous pressure (P= .030), lower pulmonary capillary wedge pressure (P= .027), and smaller left ventricular size (P= .019) compared to those with the angle >28 degrees. Right ventricular size and parameters of right ventricular function were also better in the narrow angle group, as was one-year cumulative incidence of death or heart failure readmission (10% vs. 50%,P= .008). Narrow cannula coronal angle in patients with HeartMate 3 LVADs was associated with improved cardiac unloading and lower incidence of death or heart failure readmission. Larger studies to confirm the implication of optimal device positioning are warranted.
引用
收藏
页码:E509 / E519
页数:11
相关论文
共 50 条
  • [31] Sound analysis of the magnetically levitated left ventricular assist device HeartMate 3™
    Sundbom, Per
    Roth, Michael
    Granfeldt, Hans
    Karlsson, Daniel M.
    Ahn, Henrik
    Gustafsson, Fredrik
    Dellgren, Goran
    Hubbert, Laila
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2019, 42 (12): : 717 - 724
  • [32] Aortic Insufficiency During HeartMate 3 Left Ventricular Assist Device Support
    Imamura, Teruhiko
    Narang, Nikhil
    Kim, Gene
    Nitta, Daisuke
    Fujino, Takeo
    Nguyen, Ann
    Grinstein, Jonathan
    Rodgers, Daniel
    Ota, Takeyoshi
    Jeevanandam, Valluvan
    Sayer, Gabriel
    Uriel, Nir
    [J]. JOURNAL OF CARDIAC FAILURE, 2020, 26 (10) : 863 - 869
  • [33] One-year outcomes with the HeartMate 3 left ventricular assist device
    Hanke, Jasmin S.
    Dogan, Guenes
    Zoch, Amelie
    Ricklefs, Marcel
    Wert, Leonhard
    Feldmann, Christina
    Bara, Christoph
    Shrestha, Malakh
    Tillmanns, Jochen
    Kempf, Tibor
    Bauersachs, Johann
    Haverich, Axel
    Schmitto, Jan D.
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2018, 156 (02): : 662 - 669
  • [34] A new tool for an explantation strategy of HeartMate 3™ left ventricular assist device
    Ricklefs, Marcel
    Deodhar, Chinmay
    Chatterjee, Anamika
    Feldmann, Christina
    Hanke, Jasmin S.
    Heimeshoff, Jan
    Merz, Constanze
    Deniz, Ezin
    Dogan, Guenes
    Haverich, Axel
    Schmitto, Jan D.
    [J]. JOURNAL OF THORACIC DISEASE, 2018, 10 : S1825 - S1828
  • [35] Pulmonary Artery Dissection In A Patient With Heartmate 3 Left Ventricular Assist Device
    Rao, Roopa
    Saleem, Kashif
    Guglin, Maya
    Onyedika, Ilonze
    Jones, Mark
    Ballut, Kareem
    [J]. JOURNAL OF CARDIAC FAILURE, 2022, 28 (05) : S122 - S123
  • [36] Warfarin Discontinuation in Patients with HeartMate3 Left Ventricular Assist Device
    Patel, P.
    Bhatia-Patel, S.
    Sykalo, C.
    Thigpen, C.
    Adams, A.
    Egolum, U.
    Howard, B.
    Gupta, D.
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2022, 41 (04): : S461 - S461
  • [37] Predictors of Stroke on Heartmate II Left Ventricular Assist Device
    Kar, B.
    Basra, S.
    Loyalka, P.
    Gregoric, I.
    Delgado, R.
    Civitello, A.
    Bogaev, R.
    Cohn, W.
    Attallah, A.
    Wagle, R.
    Frazier, O. H.
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2009, 28 (02): : S244 - S245
  • [38] Treatment of an Intercostal Left Ventricular Assist Device Prolapse by Upgrading From HeartMate II to HeartMate 3
    Wert, Leonhard
    Hanke, Jasmin Sarah
    Rojas, Sebastian V.
    Dogan, Guenes
    Feldmann, Christina
    Rodt, Thomas
    Haverich, Axel
    Schmitto, Jan Dieter
    [J]. ARTIFICIAL ORGANS, 2018, 42 (02) : 242 - 244
  • [39] HeartMate left ventricular assist device as bridge to heart transplantation
    Koul, B
    Solem, JO
    Steen, S
    Casimir-Ahn, H
    Granfeldt, H
    Lönn, UJ
    [J]. ANNALS OF THORACIC SURGERY, 1998, 65 (06): : 1625 - 1630
  • [40] Thrombus formation in a HeartMate II left ventricular assist device
    Meyer, Anna Lassia
    Kuehn, Christian
    Weidemann, Juergen
    Malehsa, Doris
    Bara, Christoph
    Fischer, Stefan
    Haverich, Axel
    Strueber, Martin
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2008, 135 (01): : 203 - 204