Left Ventricular Assist Device Inflow Cannula Position May Contribute to the Development of HeartMate II Left Ventricular Assist Device Pump Thrombosis

被引:14
|
作者
Bhama, Jay K. [1 ]
Bansal, Aditya [2 ,3 ]
机构
[1] Univ Iowa Hlth Care, Dept Surg, 200 Hawkins Dr,SE500 GH, Iowa City, IA 52246 USA
[2] Ochsner Clin Fdn, Dept Surg, New Orleans, LA USA
[3] Univ Queensland, Sch Med, Ochsner Clin Sch, New Orleans, LA USA
来源
OCHSNER JOURNAL | 2018年 / 18卷 / 02期
关键词
Cannula; chest x-ray; thrombosis; ventricular assist device;
D O I
10.31486/toj.17.0070
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Pump thrombosis (PT) is a dreaded complication after left ventricular assist device (LVAD) implantation. Problems with inflow cannula (IC) position may precipitate thrombus development. We sought to determine if IC position contributes to the development of PT. Methods: We conducted a retrospective review of 76 HeartMate II LVAD implants. The angle of the IC (AIC) to the horizontal plane was measured on chest x-rays. Patients who developed PT (PT group) were compared to the remaining patients (control group). Results: The mean age at implantation was 56 +/- 14 years, and 82% of the patients were male. Ten patients (13%) developed PT. Six (60%) required device exchange, and 4 (40%) were managed with anticoagulation and/or thrombolysis. The median AIC for all patients at implantation was 59 degrees (range, 38 degrees-98 degrees; 25th-75th interquartile range, 50 degrees-75 degrees). In the PT group, the median AIC was larger at the time of PT diagnosis compared to implantation (70 degrees vs 60 degrees, P = 0.005). In the control group, the median AIC was also larger at follow-up compared to implantation (61 degrees vs 58 degrees, P < 0.001) although to a lesser degree than in the PT group. No difference was seen in the median AIC between the PT group and the control group at implantation (60 degrees vs 58 degrees, respectively; P = 0.668) or at follow-up (70 degrees vs 61 degrees, respectively; P = 0.309). However, the median AIC at follow-up in the PT group was significantly larger than the median AIC at implantation in the control group (70 degrees vs 58 degrees, respectively; P = 0.014). Conclusion: The HeartMate II LVAD IC position contributes to the development of PT. Regular monitoring of cannula position may help identify patients at risk for this problem.
引用
收藏
页码:131 / 135
页数:5
相关论文
共 50 条
  • [1] Left ventricular assist device and pump thrombosis: the importance of the inflow cannula position
    Kortekaas, Kirsten A.
    de Graaf, Michiel A.
    Palmen, Meindert
    Braun, Jerry
    Mertens, Bart J. A.
    Tops, Laurens F.
    Beeres, Saskia L. M. A.
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2022, 38 (12): : 2771 - 2779
  • [2] Left ventricular assist device and pump thrombosis: the importance of the inflow cannula position
    Kirsten A. Kortekaas
    Michiel A. de Graaf
    Meindert Palmen
    Jerry Braun
    Bart J. A. Mertens
    Laurens F. Tops
    Saskia L. M. A. Beeres
    [J]. The International Journal of Cardiovascular Imaging, 2022, 38 : 2771 - 2779
  • [3] Pump Position Impacts HeartMate II Left Ventricular Assist Device Thrombosis
    Kilic, Ahmet
    Ransom, John
    Maltais, Simon
    Sun, Benjamin
    Entwistle, John W., III
    Bailey, Stephen
    John, Ranjit
    Klodell, Charles T.
    Gregoric, Igor
    Sheridan, Brett
    Chuang, Joyce
    Farrar, David J.
    Sundareswaran, Kartik
    Adamson, Robert
    [J]. ASAIO JOURNAL, 2019, 65 (03) : 227 - 232
  • [4] Technique for Insertion of HeartMate II Left Ventricular Assist Device Inflow Cannula
    Soleimani, Behzad
    Stephenson, Edward R.
    Pae, Walter E.
    [J]. ANNALS OF THORACIC SURGERY, 2011, 91 (06): : 2001 - 2002
  • [5] The influence of left ventricular assist device inflow cannula position on thrombosis risk
    Ghodrati, Mojgan
    Maurer, Alexander
    Schloeglhofer, Thomas
    Khienwad, Thananya
    Zimpfer, Daniel
    Beitzke, Dietrich
    Zonta, Francesco
    Moscato, Francesco
    Schima, Heinrich
    Aigner, Philipp
    [J]. ARTIFICIAL ORGANS, 2020, 44 (09) : 939 - 946
  • [6] Association of Inflow Cannula Position with Left Ventricular Unloading and Clinical Outcomes in Patients with HeartMate II Left Ventricular Assist Device
    Imamura, Teruhiko
    Nguyen, Ann
    Chung, Ben
    Rodgers, Daniel
    Sarswat, Nitasha
    Kim, Gene
    Raikhelkar, Jayant
    Adatya, Sirtaz
    Ota, Takeyoshi
    Song, Tae
    Juricek, Colleen
    Estep, Jerry D.
    Burkhoff, Daniel
    Jeevanandam, Valluvan
    Sayer, Gabriel
    Uriel, Nir
    [J]. ASAIO JOURNAL, 2019, 65 (04) : 331 - 335
  • [7] Factors Related to Pump Thrombosis With the Heartmate II Left Ventricular Assist Device
    Klodell, Charles T.
    Massey, H. Todd
    Adamson, Robert M.
    Dean, David A.
    Horstmanshof, Douglas A.
    Ransom, John M.
    Salerno, Christopher T.
    Cowger, Jennifer A.
    Aranda, Juan M., Jr.
    Chen, Leway
    Long, James W.
    Dembitsky, Walter
    [J]. JOURNAL OF CARDIAC SURGERY, 2015, 30 (10) : 775 - 780
  • [8] Left ventricular assist device exchange for the treatment of HeartMate II pump thrombosis
    Hanke, Jasmin S.
    Dogan, Guenes
    Wert, Leonard
    Ricklefs, Marcel
    Heimeshoff, Jan
    Chatterjee, Anamika
    Feldmann, Christina
    Haverich, Axel
    Schmitto, Jan D.
    [J]. JOURNAL OF THORACIC DISEASE, 2018, 10 : S1728 - S1736
  • [9] Left ventricular assist device and pump thrombosis: the importance of the position of the inflow canula
    Kortekaas, K. Kirsten
    De Graaf, M. A.
    Palmen, M.
    Mertens, B. J. A.
    Tops, L. F.
    Beeres, S. L. M. A.
    [J]. EUROPEAN JOURNAL OF HEART FAILURE, 2021, 23 : 149 - 150
  • [10] Left Ventricular Assist Device Inflow Cannula Angle and Thrombosis Risk
    Chivukula, Venkat Keshav
    Beckman, Jennifer A.
    Prisco, Anthony R.
    Dardas, Todd
    Lin, Shin
    Smith, Jason W.
    Mokadam, Nahush A.
    Aliseda, Alberto
    Mahr, Claudius
    [J]. CIRCULATION-HEART FAILURE, 2018, 11 (04)