Effect of dose metrics and radiation risk models when optimizing CT x-ray tube voltage

被引:20
|
作者
Huda, W. [1 ]
Ogden, K. M. [2 ]
Khorasani, M. R. [2 ]
机构
[1] Med Univ S Carolina, Dept Radiol, Charleston, SC 29425 USA
[2] SUNY Syracuse, Upstate Med Univ, Dept Radiol, Syracuse, NY 13210 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2008年 / 53卷 / 17期
关键词
D O I
10.1088/0031-9155/53/17/017
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We investigated the effect of different CT dose metrics, as well as the implications of various radiation risk models, on the optimization of x-ray tube voltage (kV) in CT. Soft tissue attenuation characteristics and noise levels, obtained from CT scans of a Rando phantom, were used to compute contrast-to-noise ratios (CNR) at x- ray tube voltages between 80 and 140 kV. Four CT dose metrics were evaluated: (a) CTDIair, (b) weighted CTDIw, (c) organ dose (D-organ), and (d) effective dose (E). All doses were obtained using the ImPACT CT Dosimetry software package. Soft tissue CNR was adjusted by the modification of the mAs by assuming that CNR2 was proportional to mAs. Optimization criteria were: (a) maintaining a constant CNR at each kV and identifying the value that minimizes patient dose; and (b) maintaining a constant dose at each kV and identifying the value that maximizes CNR. We also investigated the implication for optimization strategies assuming that radiation risk is proportional to En, with n varying between 0 and 2. Optimizing with respect to phantom measurements (i.e., CTDIair and CTDIw) could generate results that differed quantitatively and qualitatively from those obtained using patient doses (i.e., Dorgan and E). For head CT scans, 140 kV offered the lowest patient doses as well as the highest CNR, whereas in abdominal scans 80 kV was optimal. Use of an optimal kV for CT imaging over current practice of using 120 kV might reduce patient doses by 10- 15%, or improve CNR by 5- 10%. Assuming that the risk was proportional to En made no difference to the optimal kV for positive values of n up to 2. We conclude that (a) CT optimization with respect to kV should generally be performed with respect to the patient effective dose, (b) neither CTDIair nor the body CTDIw are appropriate for use in CT optimization, (c) the range of current radiation risk models should not affect the optimal kV value in CT imaging.
引用
收藏
页码:4719 / 4732
页数:14
相关论文
共 50 条
  • [31] DIRECTIONAL DISTRIBUTION OF 1040-KEV RADIATION FROM A HIGH VOLTAGE X-RAY TUBE
    GOLDSTEIN, N
    FANO, U
    WYCKOFF, HO
    [J]. JOURNAL OF APPLIED PHYSICS, 1951, 22 (04) : 417 - 418
  • [32] Irradiating cell samples in an x-ray radiation cabinet - the effect of tube filtration
    Parkin, A
    Wright, I
    Yates, S
    Goldstone, KE
    Russell, P
    Starr, C
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (05): : N39 - N46
  • [33] EFFECTIVE ULTRA LOW DOSE CT PROTOCOL WITH LOWER RADIATION DOSE THAN ABDOMINAL X-RAY
    Scotland, Kymora
    Buckley, Jean
    Nugent, James
    Nicolaou, Savvas
    Zwirewich, Charles
    McLaughlin, Patrick
    Chew, Ben
    [J]. JOURNAL OF UROLOGY, 2018, 199 (04): : E735 - E735
  • [34] Imaging radiation dose in breast radiotherapy by X-ray CT calibration of Cherenkov light
    Hachadorian, R. L.
    Bruza, P.
    Jermyn, M.
    Gladstone, D. J.
    Pogue, B. W.
    Jarvis, L. A.
    [J]. NATURE COMMUNICATIONS, 2020, 11 (01)
  • [35] Imaging radiation dose in breast radiotherapy by X-ray CT calibration of Cherenkov light
    R. L. Hachadorian
    P. Bruza
    M. Jermyn
    D. J. Gladstone
    B. W. Pogue
    L. A. Jarvis
    [J]. Nature Communications, 11
  • [36] X-ray radiation source for total dose radiation studies
    Bisello, D
    Candelori, A
    Kaminski, A
    Litovchenko, A
    Noah, E
    Stefanutti, L
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2004, 71 (3-4) : 713 - 715
  • [37] Simulation of the intensity of X-ray tube radiation in soft X-ray and extreme UV regions
    A. E. Pestov
    N. N. Salashchenko
    N. I. Chkhalo
    [J]. Bulletin of the Russian Academy of Sciences: Physics, 2008, 72 (2) : 201 - 203
  • [38] Effect of Tube Housing Leakage from X-ray Imaging System Tube Housing on Patient Dose
    Steege, P. C.
    Gainor, J. P.
    Wilson, R. F.
    [J]. HEALTH PHYSICS, 2023, 125 (01): : 29 - 30
  • [39] Mathematical Models of Radiation Transparency of Test Objects When Using Sandwich X-Ray Radiation Detectors
    V. A. Udod
    S. E. Vorobeichikov
    S. Yu. Nazarenko
    [J]. Russian Journal of Nondestructive Testing, 2020, 56 : 161 - 170
  • [40] Mathematical Models of Radiation Transparency of Test Objects When Using Sandwich X-Ray Radiation Detectors
    Udod, V. A.
    Vorobeichikov, S. E.
    Nazarenko, S. Yu.
    [J]. RUSSIAN JOURNAL OF NONDESTRUCTIVE TESTING, 2020, 56 (02) : 161 - 170