Imaging radiation dose in breast radiotherapy by X-ray CT calibration of Cherenkov light

被引:0
|
作者
R. L. Hachadorian
P. Bruza
M. Jermyn
D. J. Gladstone
B. W. Pogue
L. A. Jarvis
机构
[1] Dartmouth College,Thayer School of Engineering
[2] DoseOptics LLC,undefined
[3] Geisel School of Medicine,undefined
[4] Dartmouth College,undefined
[5] Norris Cotton Cancer Center at Dartmouth Hitchcock Medical Center,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Imaging Cherenkov emission during radiation therapy cancer treatments can provide a real-time, non-contact sampling of the entire dose field. The emitted Cherenkov signal generated is proportional to deposited dose, however, it is affected by attenuation from the intrinsic tissue optical properties of the patient, which in breast, ranges from primarily adipose to fibroglandular tissue. Patients being treated with whole-breast X-ray radiotherapy (n = 13) were imaged for 108 total fractions, to establish correction factors from the linear relationships between Cherenkov light and CT number (HU). This study elucidates this relationship in vivo, and a correction factor approach is used to scale each image to improve the linear correlation between Cherenkov emission intensity and dose (R6X2=0.85,R10X2=0.95\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$R_{6X}^2 = 0.85,\,R_{10X}^2 = 0.95$$\end{document}). This study provides a major step towards direct quantitative radiation dose imaging in humans by utilizing non-contact camera sensing of Cherenkov emission during the radiation therapy treatment.
引用
收藏
相关论文
共 50 条
  • [1] Imaging radiation dose in breast radiotherapy by X-ray CT calibration of Cherenkov light
    Hachadorian, R. L.
    Bruza, P.
    Jermyn, M.
    Gladstone, D. J.
    Pogue, B. W.
    Jarvis, L. A.
    [J]. NATURE COMMUNICATIONS, 2020, 11 (01)
  • [2] Imaging Dose in Breast Radiotherapy by X-Ray CT Calibration of Cherenkov Light
    Hachadorian, R.
    Bruza, P.
    Jermyn, M.
    Gladstone, D.
    Jarvis, L.
    Pogue, B.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E427 - E427
  • [3] Remote dose imaging from Cherenkov light using spatially resolved CT calibration in breast radiotherapy
    Hachadorian, Rachael L.
    Bruza, Petr
    Jermyn, Michael
    Gladstone, David J.
    Zhang, Rongxiao
    Jarvis, Lesley A.
    Pogue, Brian W.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : 4018 - 4025
  • [4] X-ray Cherenkov radiation
    Ispirian, KA
    [J]. Advanced Radiation Sources and Applications, 2006, 199 : 217 - 234
  • [5] A filter for breast imaging on a radiotherapy X-ray simulator
    Utting, JF
    Donovan, EM
    Suter, B
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (872): : 886 - 891
  • [6] X-RAY CHERENKOV RADIATION - THEORY AND EXPERIMENT
    BAZYLEV, VA
    GLEBOV, VI
    DENISOV, EI
    ZHEVAGO, NK
    KUMAKHOV, MA
    KHLEBNIKOV, AS
    TSINOYEV, VG
    [J]. ZHURNAL EKSPERIMENTALNOI I TEORETICHESKOI FIZIKI, 1981, 81 (05): : 1664 - 1680
  • [7] Observation of soft X-ray Cherenkov radiation in Al
    Uglov, Sergey
    Vukolov, Artem
    Kaplin, Valery
    Sukhikh, Leonid
    Karataev, Pavel
    [J]. EPL, 2017, 118 (03)
  • [8] Fresnel coefficients for parametric X-ray (Cherenkov) radiation
    Shchagin, A. V.
    [J]. PHYSICS-USPEKHI, 2015, 58 (08) : 819 - 827
  • [9] X-ray diffraction radiation in conditions of Cherenkov effect
    Tishchenko, A. A.
    Potylitsyn, A. P.
    Strikhanov, M. N.
    [J]. PHYSICS LETTERS A, 2006, 359 (05) : 509 - 511
  • [10] Visibility of microcalcification in cone beam breast CT: Effects of x-ray tube voltage and radiation dose
    Lai, Chao-Jen
    Shaw, Chris C.
    Chen, Lingyun
    Altunbas, Mustafa C.
    Liu, Xinming
    Han, Tao
    Wang, Tianpeng
    Yang, Wei T.
    Whitman, Gary J.
    Tu, Shu-Ju
    [J]. MEDICAL PHYSICS, 2007, 34 (07) : 2995 - 3004