Imaging radiation dose in breast radiotherapy by X-ray CT calibration of Cherenkov light

被引:0
|
作者
R. L. Hachadorian
P. Bruza
M. Jermyn
D. J. Gladstone
B. W. Pogue
L. A. Jarvis
机构
[1] Dartmouth College,Thayer School of Engineering
[2] DoseOptics LLC,undefined
[3] Geisel School of Medicine,undefined
[4] Dartmouth College,undefined
[5] Norris Cotton Cancer Center at Dartmouth Hitchcock Medical Center,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Imaging Cherenkov emission during radiation therapy cancer treatments can provide a real-time, non-contact sampling of the entire dose field. The emitted Cherenkov signal generated is proportional to deposited dose, however, it is affected by attenuation from the intrinsic tissue optical properties of the patient, which in breast, ranges from primarily adipose to fibroglandular tissue. Patients being treated with whole-breast X-ray radiotherapy (n = 13) were imaged for 108 total fractions, to establish correction factors from the linear relationships between Cherenkov light and CT number (HU). This study elucidates this relationship in vivo, and a correction factor approach is used to scale each image to improve the linear correlation between Cherenkov emission intensity and dose (R6X2=0.85,R10X2=0.95\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$R_{6X}^2 = 0.85,\,R_{10X}^2 = 0.95$$\end{document}). This study provides a major step towards direct quantitative radiation dose imaging in humans by utilizing non-contact camera sensing of Cherenkov emission during the radiation therapy treatment.
引用
收藏
相关论文
共 50 条
  • [41] EFFECTIVE ULTRA LOW DOSE CT PROTOCOL WITH LOWER RADIATION DOSE THAN ABDOMINAL X-RAY
    Scotland, Kymora
    Buckley, Jean
    Nugent, James
    Nicolaou, Savvas
    Zwirewich, Charles
    McLaughlin, Patrick
    Chew, Ben
    [J]. JOURNAL OF UROLOGY, 2018, 199 (04): : E735 - E735
  • [42] Calibration of a combined X-ray and laser imaging system
    Jin, Fenghua
    Jing, Hansong
    Qin, Lei
    Chen, Xin
    Tao, Yang
    [J]. OPTICS FOR NATURAL RESOURCES, AGRICULTURE, AND FOODS, 2006, 6381
  • [43] Calibration of x-ray fluorescence thyroid imaging system
    Mardirossian, G
    Matsushita, T
    Lei, K
    Clune, T
    Luo, D
    Karellas, A
    Botz, E
    Brill, AB
    [J]. PHYSICA MEDICA, 1996, 12 (02) : 83 - 92
  • [44] X-ray properties of an anthropomorphic breast phantom for MRI and x-ray imaging
    Freed, Melanie
    Badal, Andreu
    Jennings, Robert J.
    de las Heras, Hugo
    Myers, Kyle J.
    Badano, Aldo
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (12): : 3513 - 3533
  • [45] X-ray radiation source for total dose radiation studies
    Bisello, D
    Candelori, A
    Kaminski, A
    Litovchenko, A
    Noah, E
    Stefanutti, L
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2004, 71 (3-4) : 713 - 715
  • [46] New trends in X-ray CT imaging
    Deych, Ruvin
    Dolazza, Enrico
    [J]. RADIATION DETECTORS FOR MEDICAL APPLICATIONS, 2006, : 15 - +
  • [47] X-RAY CT AND NMR IMAGING OF ROCKS
    VINEGAR, HJ
    [J]. JOURNAL OF PETROLEUM TECHNOLOGY, 1986, 38 (03): : 257 - 259
  • [48] X-RAY IMAGING WITH SYNCHROTRON RADIATION.
    Cerrina, F.
    [J]. Journal of imaging science, 1986, 30 (02): : 80 - 86
  • [49] Radiation hygiene in medical X-ray imaging
    Brix, G.
    Veit, R.
    Haeusler, U.
    [J]. RADIOLOGE, 2010, 50 (10): : 913 - 925
  • [50] Radiation hygiene in medical X-ray imaging
    Nekolla, E. A.
    Griebel, J.
    Brix, G.
    [J]. RADIOLOGE, 2010, 50 (11): : 1039 - 1052