Computed Tomography Measurements as a Standard of Exophthalmos? Two-Dimensional Versus Three-Dimensional Techniques

被引:13
|
作者
Guo, Jie [1 ]
Qian, Jiang [1 ]
Yuan, Yifei [1 ]
机构
[1] Fudan Univ, Eye & ENT Hosp, Dept Ophthalmol, Myopia Key Lab,Hlth Minist, Shanghai, Peoples R China
关键词
Thyroid eye disease; exophthalmos; CT; exophthalmometer; HERTEL EXOPHTHALMOMETRY; ORBITAL DECOMPRESSION; GLOBE POSITION; ORBITOPATHY; PROTRUSION; SURGERY;
D O I
10.1080/02713683.2018.1431285
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare measurements of exophthalmos using two-dimensional (2D) and three-dimensional (3D) computed tomography (CT) methods.Methods: The CT data of 50 patients with thyroid eye disease were collected. The exophthalmos measurements were performed using both 2D and 3D methods. The protrusion of the globe center, the deviation angle of the ocular axis, and the distance between the globe center and the corneal apex were also recorded. The agreements between Hertel exophthalmometry and different CT measurements were analyzed, and the geometrical relationship between the protrusion of the corneal apex and globe center were analyzed.Results: The measurement agreement from consecutive CT scans was significantly better using the 3D method than the 2D method (p<0.05). The difference in exophthalmos measurements between the 2D and 3D methods was 0.91.2mm (p<0.05), and the 3D exophthalmos measurement was more consistent with Hertel exophthalmometry. The exophthalmos of the corneal apex and the globe center agreed with the geometrical formula well. The location error between the corneal apexes marked on the 2D and 3D images was correlated with the vertical deviation angle of the ocular axis (r=0.516).Conclusion: The reliability of CT measurements performed using a 3D method was better than those obtained using a conventional 2D method. The 3D measurements were also more consistent with the exophthalmometry results. The exophthalmos of the globe center might be considered an important reference for patients with severe strabismus.
引用
收藏
页码:647 / 653
页数:7
相关论文
共 50 条
  • [41] Two-dimensional versus three-dimensional Frankel Manoeuvre: a reproducibility study
    Rongo, Roberto
    Bucci, Rosaria
    Adaimo, Raffaella
    Amato, Massimo
    Martina, Stefano
    Valletta, Rosa
    D'Anto, Vincenzo
    [J]. EUROPEAN JOURNAL OF ORTHODONTICS, 2020, 42 (02) : 157 - 162
  • [42] Ergonomical Assessment of Three-Dimensional Versus Two-Dimensional Thoracoscopic Lobectomy
    Elkhouly, Ahmed G.
    Sorge, Roberto
    Rogliani, Paola
    Cristino, Benedetto
    Wahby, Ehab
    Serag, Amro
    Liang, Hengrui
    He, Jianxing
    Pompeo, Eugenio
    [J]. SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2020, 32 (04) : 1089 - 1096
  • [43] The use of cone beam computed tomography to predetermine root canal lengths in molar teeth: a comparison between two-dimensional and three-dimensional measurements
    Tchorz, J. P.
    Poxleitner, P. J.
    Stampf, S.
    Patzelt, S. B. M.
    Rottke, D.
    Hellwig, E.
    Altenburger, M. J.
    [J]. CLINICAL ORAL INVESTIGATIONS, 2014, 18 (04) : 1129 - 1133
  • [44] Accuracy of craniofacial measurements:: computed tomography and three-dimensional computed tomography compared with stereolithographic models
    Fruehwald, Julia
    Schicho, Kurt A.
    Figl, Michael
    Benesch, Thomas
    Watzinger, Franz
    Kainberger, Franz
    [J]. JOURNAL OF CRANIOFACIAL SURGERY, 2008, 19 (01) : 22 - 26
  • [45] The use of cone beam computed tomography to predetermine root canal lengths in molar teeth: a comparison between two-dimensional and three-dimensional measurements
    J. P. Tchorz
    P. J. Poxleitner
    S. Stampf
    S. B. M. Patzelt
    D. Rottke
    E. Hellwig
    M. J. Altenburger
    [J]. Clinical Oral Investigations, 2014, 18 : 1129 - 1133
  • [46] Comparison of three-dimensional and two-dimensional computed tomographies in the classification of acetabular fractures
    Kanthawang, Thanat
    Vaseenon, Tanawat
    Sripan, Patumrat
    Pattamapaspong, Nuttaya
    [J]. EMERGENCY RADIOLOGY, 2020, 27 (02) : 157 - 164
  • [47] Comparison of three-dimensional and two-dimensional computed tomographies in the classification of acetabular fractures
    Thanat Kanthawang
    Tanawat Vaseenon
    Patumrat Sripan
    Nuttaya Pattamapaspong
    [J]. Emergency Radiology, 2020, 27 : 157 - 164
  • [48] Three-Dimensional versus Two-Dimensional Evaluations of Cranial Asymmetry in Deformational Plagiocephaly Using a Three-Dimensional Scanner
    Kato, Risa
    Nagano, Nobuhiko
    Hashimoto, Shin
    Saito, Katsuya
    Miyabayashi, Hiroshi
    Noto, Takanori
    Morioka, Ichiro
    [J]. CHILDREN-BASEL, 2022, 9 (06):
  • [49] Measurements of pelvic flexion angle using three-dimensional computed tomography
    Nishihara, S
    Sugano, N
    Nishii, T
    Ohzono, K
    Yoshikawa, H
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (411) : 140 - 151
  • [50] Comparison of exophthalmos measurements: Hertel exophthalmometer versus orbital parameters in 2-dimensional computed tomography
    Choi, Kyung Jun
    Lee, Min Joung
    [J]. CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2018, 53 (04): : 384 - 390