Computed Tomography Measurements as a Standard of Exophthalmos? Two-Dimensional Versus Three-Dimensional Techniques

被引:13
|
作者
Guo, Jie [1 ]
Qian, Jiang [1 ]
Yuan, Yifei [1 ]
机构
[1] Fudan Univ, Eye & ENT Hosp, Dept Ophthalmol, Myopia Key Lab,Hlth Minist, Shanghai, Peoples R China
关键词
Thyroid eye disease; exophthalmos; CT; exophthalmometer; HERTEL EXOPHTHALMOMETRY; ORBITAL DECOMPRESSION; GLOBE POSITION; ORBITOPATHY; PROTRUSION; SURGERY;
D O I
10.1080/02713683.2018.1431285
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare measurements of exophthalmos using two-dimensional (2D) and three-dimensional (3D) computed tomography (CT) methods.Methods: The CT data of 50 patients with thyroid eye disease were collected. The exophthalmos measurements were performed using both 2D and 3D methods. The protrusion of the globe center, the deviation angle of the ocular axis, and the distance between the globe center and the corneal apex were also recorded. The agreements between Hertel exophthalmometry and different CT measurements were analyzed, and the geometrical relationship between the protrusion of the corneal apex and globe center were analyzed.Results: The measurement agreement from consecutive CT scans was significantly better using the 3D method than the 2D method (p<0.05). The difference in exophthalmos measurements between the 2D and 3D methods was 0.91.2mm (p<0.05), and the 3D exophthalmos measurement was more consistent with Hertel exophthalmometry. The exophthalmos of the corneal apex and the globe center agreed with the geometrical formula well. The location error between the corneal apexes marked on the 2D and 3D images was correlated with the vertical deviation angle of the ocular axis (r=0.516).Conclusion: The reliability of CT measurements performed using a 3D method was better than those obtained using a conventional 2D method. The 3D measurements were also more consistent with the exophthalmometry results. The exophthalmos of the globe center might be considered an important reference for patients with severe strabismus.
引用
收藏
页码:647 / 653
页数:7
相关论文
共 50 条
  • [1] Two-Dimensional Versus Three-Dimensional Computed Tomography Reply
    Lindenhovius, Anneluuk
    Ring, David
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2010, 35A (03): : 513 - 514
  • [2] A comparison of two-dimensional radiography and three-dimensional computed tomography in angular cephalometric measurements
    Nalcaci, R.
    Ozturk, F.
    Sokucu, O.
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2010, 39 (02) : 100 - 106
  • [3] Three-dimensional volumetric measurement of the aortic root compared to standard two-dimensional measurements using cardiac computed tomography
    Suzuki, Masataka
    Mori, Shumpei
    Izawa, Yu
    Shimoyama, Shinsuke
    Takahashi, Yu
    Toh, Hiroyuki
    Tsuda, Daisuke
    Toba, Takayoshi
    Fujiwara, Sei
    Tanaka, Hidekazu
    Hirata, Ken-ichi
    Anderson, Robert H.
    Tretter, Justin T.
    [J]. CLINICAL ANATOMY, 2021, 34 (03) : 333 - 341
  • [4] Interobserver Reliability of Coronoid Fracture Classification: Two-Dimensional Versus Three-Dimensional Computed Tomography
    Lindenhovius, Anneluuk
    Karanicolas, Paul Jack
    Bhandari, Mohit
    van Dijk, Nick
    Ring, David
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2009, 34A (09): : 1640 - 1646
  • [5] Left atrial volumes: two-dimensional, three-dimensional, cardiac magnetic resonance and computed tomography measurements
    Boyd, Anita C.
    Thomas, Liza
    [J]. CURRENT OPINION IN CARDIOLOGY, 2014, 29 (05) : 408 - 416
  • [6] Two-dimensional versus three-dimensional radiographic measurements of polyethylene wear
    Sychterz, CJ
    Yang, AM
    McAuley, JP
    Engh, CA
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1999, (365) : 117 - 123
  • [7] Comparison of standard two-dimensional and three-dimensional corrected glenoid version measurements
    Budge, Matthew D.
    Lewis, Gregory S.
    Schaefer, Eric
    Coquia, Stephanie
    Flemming, Donald J.
    Armstrong, April D.
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2011, 20 (04) : 577 - 583
  • [8] Two-Dimensional and Three-Dimensional Cephalometry Using Cone Beam Computed Tomography Scans
    Michele, Cassetta
    Federica, Altieri
    Roberto, Di Giorgio
    Alessandro, Silvestri
    [J]. JOURNAL OF CRANIOFACIAL SURGERY, 2015, 26 (04) : E311 - E315
  • [9] Two-dimensional and three-dimensional computed tomography for the classification and characterisation of tibial plateau fractures
    Doornberg, Job N.
    Rademakers, Maarten V.
    van den Bekerom, Michel P.
    Kerkhoffs, Gino M.
    Ahn, Jaimo
    Steller, E. Ph.
    Kloen, Peter
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2011, 42 (12): : 1416 - 1425
  • [10] Three-dimensional diffraction tomography by two-dimensional sectioning
    Halse, OR
    Stammes, JJ
    Devaney, AJ
    [J]. OPTICS COMMUNICATIONS, 2003, 224 (4-6) : 185 - 195