Detection of Mycoplasma pneumoniae by loop-mediated isothermal amplification (LAMP) assay and serology in pediatric community-acquired pneumonia

被引:44
|
作者
Gotoh, Kensei [1 ]
Nishimura, Naoko [1 ]
Ohshima, Yasunori [1 ]
Arakawa, Yasuko [1 ]
Hosono, Haruki [1 ]
Yamamoto, Yasuto [1 ]
Iwata, Yasushi [2 ]
Nakane, Kazumasa [2 ]
Funahashi, Keiji [2 ]
Ozaki, Takao [1 ]
机构
[1] Konan Kosei Hosp, Dept Pediat, Konan, Aichi 4838704, Japan
[2] Konan Kosei Hosp, Dept Clin Lab, Konan, Aichi 4838704, Japan
关键词
Mycoplasma pneumoniae; Pediatric community-acquired pneumonia (CAP); Rapid diagnosis; Loop-mediated isothermal amplification (LAMP); POLYMERASE-CHAIN-REACTION; RESPIRATORY-TRACT INFECTION; REAL-TIME PCR; RAPID DIAGNOSIS; MACROLIDE RESISTANCE; VIRUS DNA; CHILDREN; NASOPHARYNGEAL; PREVALENCE; UTILITY;
D O I
10.1007/s10156-012-0388-5
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Rapid diagnosis of Mycoplasma pneumoniae pneumonia is required for treatment with effective antimicrobial agents without delay; however, this capacity has not yet been established in clinical practice. Recently, a novel nucleic acid amplification method termed loop-mediated isothermal amplification (LAMP) has been used to rapidly diagnose various infectious diseases. In this study, we prospectively evaluated the efficacy of the LAMP assay to rapidly diagnose M. pneumoniae pneumonia in clinical practice. Three hundred sixty-eight children (median age, 3.8 years; range, 0.1-14.3 years) admitted to our hospital between April 2009 and March 2010 for community-acquired pneumonia were enrolled in this study. We obtained throat swabs on admission to detect M. pneumoniae DNA and paired serum samples on admission and at discharge to assay M. pneumoniae antibody titers. M. pneumoniae pneumonia was diagnosed by either a positive LAMP assay or a fourfold or greater increase in antibody titer. Overall, 46 children (12.5% of the patients with pneumonia) were diagnosed with M. pneumoniae pneumonia; of these, 27 (58.7%) were aged less than 6 years. Of the aforementioned 46 children, 38 (82.6%) and 37 (80.4%) were identified by LAMP and serology, respectively. When the results of serology were taken as the standard, the sensitivity and specificity and positive and negative predictive values of the LAMP assay were 78.4%, 97.3%, 76.3%, and 97.6%, respectively. We concluded the LAMP assay may be useful for rapid diagnosis of M. pneumoniae pneumonia.
引用
收藏
页码:662 / 667
页数:6
相关论文
共 50 条
  • [21] Detection of Fusarium graminearum DNA using a loop-mediated isothermal amplification (LAMP) assay
    Niessen, Ludwig
    Vogel, Rudi F.
    [J]. INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 2010, 140 (2-3) : 183 - 191
  • [22] Loop-Mediated Isothermal Amplification (LAMP) for the Detection of Salmonella in Food
    P. A. Kokkinos
    P. G. Ziros
    M. Bellou
    A. Vantarakis
    [J]. Food Analytical Methods, 2014, 7 : 512 - 526
  • [23] Development of a loop-mediated isothermal amplification assay for sensitive and rapid detection of Mycoplasma bovis
    Bai, ZhiDi
    Shi, Lei
    Hu, Changmin
    Chen, Xi
    Qi, Jingjing
    Ba, Xiaoliang
    Peng, Qingjie
    Chen, Yingyu
    Chen, Huanchun
    Guo, Aizhen
    [J]. AFRICAN JOURNAL OF BIOTECHNOLOGY, 2011, 10 (57): : 12333 - 12338
  • [24] Detection of phytoplasma by loop-mediated isothermal amplification of DNA (LAMP)
    Obura, E.
    Masiga, D.
    Wachira, F.
    Gurja, B.
    Khan, Z. R.
    [J]. JOURNAL OF MICROBIOLOGICAL METHODS, 2011, 84 (02) : 312 - 316
  • [25] Loop-Mediated Isothermal Amplification (LAMP) for the Detection of Salmonella in Food
    Kokkinos, P. A.
    Ziros, P. G.
    Bellou, M.
    Vantarakis, A.
    [J]. FOOD ANALYTICAL METHODS, 2014, 7 (02) : 512 - 526
  • [26] Rapid detection of Mycoplasma synoviae by loop-mediated isothermal amplification
    Olimpia Kursa
    Grzegorz Woźniakowski
    Grzegorz Tomczyk
    Anna Sawicka
    Zenon Minta
    [J]. Archives of Microbiology, 2015, 197 : 319 - 325
  • [27] Rapid detection of the Klebsiella pneumoniae carbapenemase (KPC) gene by loop-mediated isothermal amplification (LAMP)
    Nakano, Ryuichi
    Nakano, Akiyo
    Ishii, Yoshikazu
    Ubagai, Tsuneyuki
    Kikuchi-Ueda, Takane
    Kikuchi, Hirotoshi
    Tansho-Nagakawa, Shigeru
    Kamoshida, Go
    Mu, Xiaoqin
    Ono, Yasuo
    [J]. JOURNAL OF INFECTION AND CHEMOTHERAPY, 2015, 21 (3-4) : 202 - 206
  • [28] Rapid detection of Mycoplasma synoviae by loop-mediated isothermal amplification
    Kursa, Olimpia
    Wozniakowski, Grzegorz
    Tomczyk, Grzegorz
    Sawicka, Anna
    Minta, Zenon
    [J]. ARCHIVES OF MICROBIOLOGY, 2015, 197 (02) : 319 - 325
  • [29] Rapid and efficient detection of mycoplasma pneumonia RNA by reverse-transcription loop-mediated isothermal amplification (RT-LAMP)
    Ma, Cuiping
    Yan, Chunyu
    Shi, Chao
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2018, 255
  • [30] Detection of Streptococcus pneumoniae in Urine by Loop-Mediated Isothermal Amplification
    Cima-Cabal, Maria Dolores
    Vazquez-Espinosa, Emma
    Vazquez, Fernando
    Garcia-Suarez, Maria del Mar
    [J]. JOURNAL OF PEDIATRIC INFECTIOUS DISEASES, 2021, 16 (01) : 18 - 25