Bilateral Comparison of 1 V and 10 V Standards between the NIS (Egypt) and the BIPM, August to September 2014 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

被引:0
|
作者
Solve, S. [1 ]
Chayramy, R. [1 ]
Stock, M. [1 ]
Mageed, Hala M. Abdel [2 ]
Aladdin, Omar M. [2 ]
Raouf, M. Helmy A. [2 ]
机构
[1] Bur Int Poids & Mesures, Sevres, France
[2] Natl Inst Stand, MA El Sadat Tersa, Giza 11221, Egypt
关键词
DC voltage - Josephson voltage standards - Key comparison - Main texts - Reference standard - Standard uncertainty - Travelling standard - Voltage reference - Voltage standard;
D O I
10.1088/0026-1394/52/1A/01011
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1 V and 10 V voltage reference standards of the BIPM and the National Institute for Standards (NIS), Giza, Egypt, was carried out from August to September 2014. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM_B (ZB) and BIPM_C (ZC), were transported as hand luggage on board an airplane to NIS and back to BIPM. At NIS, the reference standard for DC voltage is a Josephson Voltage Standard. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at NIS, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned to DC voltage standards by NIS, at the level of 1.018 V and 10 V, at NIS, U-NIS, and those assigned by the BIPM, at the BIPM, U-BIPM, at the reference date of the 7 September 2014. U-NIS - U-BIPM = 0.09 mu V; u(c) = 0.08 mu V, at 1 V U-NIS - U-BIPM = 0.22 mu V; u(c) = 0.14 mu V, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NIS, based on KJ-90, and the uncertainty related to the comparison. This is a satisfactory result. The comparison result shows that the voltage standards maintained by NIS and the BIPM were equivalent, within their stated standard uncertainties, on the mean date of the comparison.
引用
收藏
页数:2
相关论文
共 50 条
  • [41] Bilateral comparison of 10 kΩ standards (ongoing BIPM key comparison BIPM.EM-K13.b) between the CMI (Czech Republic) and the BIPM
    Goebel, R.
    Chrobok, P.
    Fletcher, N.
    Stock, M.
    [J]. METROLOGIA, 2008, 45
  • [42] Comparison of the Josephson Voltage Standards of the INTI and the BIPM (part of the ongoing BIPM key comparison BIPM.EM-K10.a)
    Solve, S.
    Chayramy, R.
    Stock, M.
    Iuzzolino, R.
    Tonina, A.
    [J]. METROLOGIA, 2012, 49
  • [43] Bilateral comparison of 10 V standards between the NSAI - NML (Ireland) and the BIPM (BIPM.EM-K11.b)
    Solve, Stephane
    Chayramy, Regis
    Stock, Michael
    Power, Oliver
    [J]. METROLOGIA, 2019, 56 (1A)
  • [44] Comparison of the Josephson Voltage Standards of the NIMT and the BIPM (part of the ongoing BIPM key comparison BIPM. EM-K10.b)
    Solve, S.
    Chayramy, R.
    Stock, M.
    Pimsut, S.
    Rujirat, N.
    [J]. METROLOGIA, 2016, 53
  • [45] Bilateral comparison of 10 kΩ standards (ongoing BIPM key comparison BIPM.EM-K13.b) between the NSAI-NML (Ireland) and the BIPM
    Goebel, R.
    Power, O.
    Fletcher, N.
    Stock, M.
    [J]. METROLOGIA, 2012, 49
  • [46] Comparison of the Josephson Voltage Standards of the NMC, A*STAR and the BIPM (part of the ongoing BIPM key comparisons BIPM.EM-K10.a and BIPM.EM-K10.b)
    Solve, S.
    Chayramy, R.
    Stock, M.
    Zhou, Yinzhu
    Lee, Jinni
    Chua, Sze Wey
    [J]. METROLOGIA, 2011, 48
  • [47] Final report on the bilateral comparison of 1 Ω standards (ongoing BIPM key comparison BIPM.EM-K13.a) between the NIST (USA) and the BIPM
    Goebel, R.
    Elmquist, R.
    Fletcher, N.
    Stock, M.
    [J]. METROLOGIA, 2008, 45
  • [48] Final report on bilateral comparison of 10 kΩ standards (ongoing BIPM key comparison BIPM.EM-K13.b) between the NIMT-Thailand and the BIPM
    Goebel, R.
    Kurupakorn, C.
    Fletcher, N.
    Stock, M.
    [J]. METROLOGIA, 2010, 47
  • [49] Bilateral comparison of 1 Ω and 10 kΩ; standards (ongoing BIPM key comparisons BIPM.EM-K13.a and 13.b) between the NPLI (India) and the BIPM
    Fletcher, N.
    Goebel, R.
    Saleem, M.
    Singh, H. K.
    Ansari, M. A.
    Kiran, U.
    Saxena, A. K.
    [J]. METROLOGIA, 2019, 56 (1A)
  • [50] Bilateral comparison of 1 Ω and 10 kΩ standards (ongoing BIPM key comparisons BIPM.EM-K13.a and 13.b) between the CEM (Spain) and the BIPM
    Rolland, B.
    Stock, M.
    Gournay, P.
    Matías, L.
    Hortelano, A.
    Raso, F.
    Díaz de Aguilar, J.
    [J]. Metrologia, 2023, 60 (1A)