Frequency Tuning of Collapse-Mode Capacitive Micromachined Ultrasonic Transducer

被引:21
|
作者
Pekar, Martin [1 ,2 ]
Dittmer, Wendy U. [1 ]
Mihajlovic, Nenad [1 ]
van Soest, Gijs [2 ]
de Jong, Nico [2 ,3 ]
机构
[1] Philips Res, Royal Philips NV, Eindhoven, Netherlands
[2] Erasmus MC, Dept Biomed Engn, Ctr Thorax, Rotterdam, Netherlands
[3] Delft Univ Technol, Dept Imaging Phys, Lab Acoust Wavefield Imaging, Delft, Netherlands
关键词
CMUT; Capacitive micromachined ultrasonic transducer; Ultrasound; Multi-frequency; Imaging; Intracardiac; Frequency tuning; Collapse mode; Deep-collapse mode; CMUT ARRAYS; OPERATION;
D O I
10.1016/j.ultras.2016.10.002
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The information in an ultrasound image depends on the frequency that is used. In a clinical examination it may therefore be beneficial to generate ultrasound images acquired at multiple frequencies, which is difficult to achieve with conventional transducers. Capacitive micromachined ultrasonic transducers (CMUTs) offer a frequency response that is tunable by the bias voltage. In this study we investigate this frequency tunability for ultrasonic imaging. We characterized a CMUT array operated at bias voltages up to three times higher than the collapse-voltage. All elements of the array were connected to a single transmit and receive channel through a bias circuit. We quantified the transmit-receive and transmit sensitivity as a function of frequency for a range of bias voltages. Impulse response measurements show that the center frequency is modifiable between 8.7 MHz and 15.3 MHz with an applied bias voltage of -50 V to 170 V. The maximum transmit sensitivity is 52 kPa/V at a center frequency of 9.0 MHz with an applied bias voltage of 105 V. The 3 dB transmit range in center frequency accessible with the variable bias voltage is 6.7-15.5 MHz. This study shows that a collapse-mode CMUT can operate efficiently at multiple center frequelicies when the driving pulse and the bias voltage are optimized. We demonstrate the usefulness of frequency tuning by comparing images at different optimal combinations of driving frequency and bias voltage, acquired by lineally moving the transducer across a tissue mimicking phantom. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:144 / 152
页数:9
相关论文
共 50 条
  • [41] Detailed investigation of capacitive micromachined ultrasonic transducer design space
    Onen, Onursal
    Guldiken, Rasim
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2012, 18 (04): : 399 - 408
  • [42] Analytical Model for Pressure Sensing with Capacitive Micromachined Ultrasonic Transducer
    Sun, Yue
    Zheng, Zhou
    Song, Yuchen
    Chen, Hui
    Wang, Xiaomin
    Sun, Zhendong
    39TH YOUTH ACADEMIC ANNUAL CONFERENCE OF CHINESE ASSOCIATION OF AUTOMATION, YAC 2024, 2024, : 1060 - 1063
  • [43] A Capacitive Micromachined Ultrasonic Transducer Probe for Assessment of Cortical Bone
    Boulme, Audren
    Ngo, Sophie
    Minonzio, Jean-Gabriel
    Legros, Mathieu
    Talmant, Maryline
    Laugier, Pascal
    Certon, Dominique
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2014, 61 (04) : 710 - 723
  • [44] Design of air-coupled capacitive micromachined ultrasonic transducer
    Zhang, Hui
    Li, Zhi
    Zheng, Guanru
    Zeng, Zhoumo
    Shengxue Xuebao/Acta Acustica, 2019, 44 (01): : 116 - 124
  • [45] Modeling and investigation of immersion based capacitive micromachined ultrasonic transducer
    Lalnunfeli, H.
    Maity, Reshmi
    Tiwari, R. C.
    Dutta, Shankar
    Maity, Niladri Pratap
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2024, 30 (10): : 1315 - 1324
  • [46] Analytical Modelling of Hexagonal Shaped Capacitive Micromachined Ultrasonic Transducer
    Rashmi Sharma
    Rekha Agarwal
    Ashwani Kumar Dubey
    Anil Arora
    International Journal of System Assurance Engineering and Management, 2021, 12 : 252 - 262
  • [47] Capacitive micromachined ultrasonic transducer design for high power transmission
    Bayram, B
    Oralkan, Ö
    Ergun, AS
    Hæggström, E
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2005, 52 (02) : 326 - 339
  • [48] A Study on Capacitive Micromachined Ultrasonic Transducer Periodic Sparse Array
    Zhang, Tian
    Zhang, Wendong
    Shao, Xingling
    Yang, Yuhua
    Wang, Zhihao
    Wu, Yang
    Pei, Yu
    MICROMACHINES, 2021, 12 (06)
  • [49] Design and Experiment of Capacitive Micromachined Ultrasonic Transducer Array for High-frequency Underwater Imaging
    Yu, Yuanyu
    Wang, Jiujiang
    Liu, Xin
    Pun, Sio H.
    Qiu, Weibao
    Zhang, Shuang
    Cheng, Ching H.
    Lei, Kin F.
    Vai, Mang, I
    Mak, Peng U.
    RECENT ADVANCES IN ELECTRICAL & ELECTRONIC ENGINEERING, 2021, 14 (02) : 233 - 240
  • [50] Design and experiment of capacitive micromachined ultrasonic transducer array for high-frequency underwater imaging
    Yu, Yuanyu
    Wang, Jiujiang
    Liu, Xin
    Pun, Sio H.
    Qiu, Weibao
    Zhang, Shuang
    Cheng, Ching H.
    Lei, Kin F.
    Vai, Mang I.
    Mak, Peng U.
    Recent Advances in Electrical and Electronic Engineering, 2021, 14 (02): : 233 - 240