Effects of acquisition time and reconstruction algorithm on image quality, quantitative parameters, and clinical interpretation of myocardial perfusion imaging

被引:15
|
作者
Enevoldsen, Lotte H. [1 ]
Menashi, Changez A. K. [1 ]
Andersen, Ulrik B. [1 ]
Jensen, Lars T. [1 ]
Henriksen, Otto M. [1 ]
机构
[1] Glostrup Cty Hosp, Sect Clin Physiol & Nucl Med, Dept Diagnost, DK-2600 Glostrup, Denmark
关键词
Myocardial perfusion imaging; single photon emission computed tomography; stress testing; coronary artery disease; Tc-99m MIBI; SUBSET EXPECTATION MAXIMIZATION; RESOLUTION RECOVERY; FILTERED BACKPROJECTION; SPECT; HALF; DISEASE;
D O I
10.1007/s12350-013-9775-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Recently introduced iterative reconstruction algorithms with resolution recovery (RR) and noise-reduction technology seem promising for reducing scan time or radiation dose without loss of image quality. However, the relative effects of reduced acquisition time and reconstruction software have not previously been reported. The aim of the present study was to investigate the influence of reduced acquisition time and reconstruction software on quantitative and qualitative myocardial perfusion single photon emission computed tomography (SPECT) parameters using full time (FT) and half time (HT) protocols and Evolution for Cardiac Software. We studied 45 consecutive, non-selected patients referred for a clinically indicated routine 2-day stress/rest Tc-99m-Sestamibi myocardial perfusion SPECT. All patients underwent an FT and an HT scan. Both FT and HT scans were processed according to our standard procedure with both ordered-subset expectation maximization (OSEM) + filtered back projection (FBP) reconstructions and a second reconstruction of HT scans was performed with the RR software producing three datasets for each patient for visual analysis (FT-OSEM, HT-OSEM, and HT-RR) and for quantitative analysis (FT-FBP, HT-FBP, and HT-RR). The datasets were analyzed using commercially available QGS/QPS software and read by two observers evaluating image quality and clinical interpretation. Image quality was assessed on a 10-cm visual analog scale score. HT imaging was associated with loss of image quality that was compensated for by RR reconstruction. HT imaging was also associated with increasing perfusion defect extents, an effect more pronounced using RR than FBP reconstruction. Compared to standard FT-FBP, HT-RR significantly reduced left ventricular volumes whereas HT-FBP increased end-systolic volume. HT imaging had no effect on measured left ventricular ejections fraction or measures of reversibility. Image interpretation found a higher level of concordance between FT-OSEM and HT-RR than between FT-OSEM and HT-OSEM without any observable systematic effects. Use of RR reconstruction algorithms compensates for loss of image quality associated with reduced scan time. Both HT acquisition and RR reconstruction algorithm had significant effects on motion and perfusion parameters obtained with standard software, but these effects were relatively small and probably of limited clinical importance. Although no systematic effects on image interpretation were observed, the influence on diagnostic accuracy remains to be determined.
引用
收藏
页码:1086 / 1092
页数:7
相关论文
共 50 条
  • [41] Assessment of image quality for SPECT myocardial perfusion imaging with regard to reconstruction algorithms using visual grading regression
    Davidsson, A.
    Olsson, E.
    Engvall, J.
    Gustafsson, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S535 - S535
  • [42] Effects of data acquisition parameters on the quality of sonoelastographic imaging
    Torres, Gabriela
    Ormachea, Juvenal
    Lavarello, Roberto J.
    Parker, Kevin J.
    Castaneda, Benjamn
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 3839 - 3842
  • [43] A study on the effect of CT imaging acquisition parameters on lung nodule image interpretation
    Yu, Shirley J.
    Wantroba, Joseph S.
    Raicu, Daniela S.
    Furst, Jacob D.
    Channin, David S.
    Armato, Samuel G., III
    MEDICAL IMAGING 2009: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2009, 7263
  • [44] Effects of Time of Flight image reconstruction on myocardial perfusion 13N-ammonia PET/CT
    Olsson, B.
    Saran, S.
    Ekholm, K.
    Evetovics, E.
    Hedeer, F.
    Jogi, J.
    Oddstig, J.
    Hindorf, C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S512 - S512
  • [45] Impact of image denoising on image quality, quantitative parameters and sensitivity of ultra-low-dose volume perfusion CT imaging
    Ahmed E. Othman
    Carolin Brockmann
    Zepa Yang
    Changwon Kim
    Saif Afat
    Rastislav Pjontek
    Omid Nikoubashman
    Marc A. Brockmann
    Konstantin Nikolaou
    Martin Wiesmann
    Jong Hyo Kim
    European Radiology, 2016, 26 : 167 - 174
  • [46] Impact of image denoising on image quality, quantitative parameters and sensitivity of ultra-low-dose volume perfusion CT imaging
    Othman, Ahmed E.
    Brockmann, Carolin
    Yang, Zepa
    Kim, Changwon
    Afat, Saif
    Pjontek, Rastislav
    Nikoubashman, Omid
    Brockmann, Marc A.
    Nikolaou, Konstantin
    Wiesmann, Martin
    Kim, Jong Hyo
    EUROPEAN RADIOLOGY, 2016, 26 (01) : 167 - 174
  • [47] Optimal timing of image acquisition for arterial first pass CT myocardial perfusion imaging
    Pelgrim, J.
    Nieuwenhuis, E. R.
    Duguay, T. M.
    van der Geest, R. J.
    Varga-Szemes, A.
    Slump, C. H.
    Fuller, S. R.
    Oudkerk, M.
    Schoepf, U. J.
    Vliegenthart, R.
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 86 : 227 - 233
  • [48] Shorter acquisition time of myocardial perfusion SPECT study using a novel reconstruction method
    Braun, Shimon S.
    Chausovsky, G.
    Yuzefovich, B.
    Sachs, J.
    Keren, G.
    Even-Sapir, E.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2009, 11 (0B) : S57 - S57
  • [49] Shortened Acquisition Time for Cardiac SPECT: Validation of a New Reconstruction Alorithm for Myocardial Perfusion
    Valenta, I.
    Treyer, V.
    Husmann, L.
    Gaemperli, O.
    Schindler, M.
    Herzog, B. A.
    Veit-Haibach, P.
    Strobel, K.
    Kaufmann, P. A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S226 - S226
  • [50] Susceptibility Weighted Imaging: Data Acquisition, Image Reconstruction and Clinical Applications
    Rauscher, Alexander
    Sedlacik, Jan
    Deistung, Andreas
    Mentzel, Hans-Joachim
    Reichenbach, Juergen R.
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2006, 16 (04): : 240 - 250