The effect of concomitant gradient fields on diffusion tensor imaging

被引:51
|
作者
Baron, C. A. [1 ]
Lebel, R. M. [1 ]
Wilman, A. H. [1 ]
Beaulieu, C. [1 ]
机构
[1] Univ Alberta, Fac Med & Dent, Dept Biomed Engn, Res Transit Facil 1064, Edmonton, AB T6G 2V2, Canada
基金
加拿大自然科学与工程研究理事会; 加拿大健康研究院;
关键词
DTI; concomitant fields; diffusion; gradient; REFOCUSED SPIN-ECHO; MAGNETIC-FIELD; MRI; ANISOTROPY; ARTIFACTS; RECONSTRUCTION; REDUCTION; SEQUENCE; MOTION; BRAIN;
D O I
10.1002/mrm.24120
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Concomitant gradient fields are transverse magnetic field components that are necessarily present to satisfy Maxwell's equations when magnetic field gradients are utilized in magnetic resonance imaging. They can have deleterious effects that are more prominent at lower static fields and/or higher gradient strengths. In diffusion tensor imaging schemes that employ large gradients that are not symmetric about a refocusing radiofrequency pulse (unlike StejskalTanner, which is symmetric), concomitant fields may cause phase accrual that could corrupt the diffusion measurement. Theory predicting the error from this dephasing is described and experimentally validated for both Reese twice-refocused and split gradient single spin-echo diffusion gradient schemes. Bias in apparent diffusion coefficient values was experimentally found to worsen with distance from isocenter and with increasing duration of gradient asymmetry in both a phantom and in the brain. The amount of error from concomitant gradient fields depends on many variables, including the diffusion gradient pattern, pulse sequence timing, maximum effective gradient amplitude, static magnetic field strength, voxel size, slice distance from isocenter, and partial Fourier fraction. A prospective correction scheme that can reduce concomitant gradient errors is proposed and verified for diffusion imaging. Magn Reson Med, 2012. (c) 2011 Wiley Periodicals, Inc.
引用
收藏
页码:1190 / 1201
页数:12
相关论文
共 50 条
  • [11] Diffusion tensor imaging of horizontal extraocular muscles in patients with concomitant and paralytic esotropia
    Ming-Hao Chen
    Jian-Hua Yan
    International Journal of Ophthalmology, 2023, (08) : 1350 - 1355
  • [12] Optimal Diffusion Gradient Encoding Scheme for Diffusion Tensor Imaging Based on Golden Ratio
    Liu, Liangyou
    Li, Zhaotong
    Zhang, Zeru
    Xia, Yifan
    Li, Sha
    Gao, Song
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2022, 55 (05) : 1571 - 1581
  • [13] SEGMENTATION OF THALAMIC NUCLEI BASED ON TENSORIAL MORPHOLOGICAL GRADIENT OF DIFFUSION TENSOR FIELDS
    Rittner, Leticia
    Lotufo, Roberto A.
    Campbell, Jennifer
    Pike, G. Bruce
    2010 7TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2010, : 1173 - 1176
  • [14] Diffusion tensor imaging segmentation by watershed transform on tensorial morphological gradient
    Rittner, Leticia
    Lotufo, Roberto
    SIBGRAPI 2008: XXI BRAZILIAN SYMPOSIUM ON COMPUTER GRAPHICS AND IMAGE PROCESSING, 2008, : 196 - 203
  • [15] Improved gradient waveforms for oscillating gradient spin-echo (OGSE) diffusion tensor imaging
    Hennel, Franciszek
    Michael, Eric Seth
    Pruessmann, Klaas P.
    NMR IN BIOMEDICINE, 2021, 34 (02)
  • [16] Estimation and application of spatially variable noise fields in diffusion tensor imaging
    Landman, Bennett A.
    Bazin, Pierre-Louis
    Prince, Jerry L.
    MAGNETIC RESONANCE IMAGING, 2009, 27 (06) : 741 - 751
  • [17] Editorial for "Optimal Diffusion Gradient Encoding Scheme for Diffusion Tensor Imaging Based on Golden Ratio"
    Cruciata, Giuseppe
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2022, 55 (05) : 1582 - 1583
  • [18] Effects of number of diffusion gradient directions on derived diffusion tensor imaging indices in human brain
    Ni, H.
    Kavcic, V.
    Zhu, T.
    Ekholm, S.
    Zhong, J.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2006, 27 (08) : 1776 - 1781
  • [19] Effect of scanner in longitudinal diffusion tensor imaging studies
    Takao, Hidemasa
    Hayashi, Naoto
    Kabasawa, Hiroyuki
    Ohtomo, Kuni
    HUMAN BRAIN MAPPING, 2012, 33 (02) : 466 - 477
  • [20] Mapping the Impact of Non-Linear Gradient Fields on Diffusion MRI Tensor Estimations
    Kanakaraj, Praitayini
    Hansen, Colin B.
    Rheault, Francois
    Cai, Leon Y.
    Ramadass, Karthik
    Rogers, Baxter P.
    Schilling, Kurt G.
    Landman, Bennett A.
    MEDICAL IMAGING 2022: IMAGE PROCESSING, 2022, 12032