Accuracy combining different brands of implants and abutments

被引:12
|
作者
Sola-Ruiz, Maria-Fernanda [1 ]
Selva-Otaolaurruchi, Eduardo [1 ]
Senent-Vicente, Gisela [1 ]
Gonzalez-de-Cossio, Ines [1 ]
Amigo-Borras, Vicente [2 ]
机构
[1] Univ Valencia, Fac Med & Dent, Dept Buccofacial Prosthet, E-46003 Valencia, Spain
[2] Univ Politecn Valencia, Dept Mech & Mat Engn, Valencia, Spain
来源
关键词
Vertical fit; implant; prosthetic abutment; combination; MARGINAL FIT; INTERFACE; MISFIT; PROSTHESES; STABILITY;
D O I
10.4317/medoral.18137
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To evaluate the vertical misfit between different brands of dental implants and prosthetic abutments, with or without mechanical torque, and to study their possible combination. Study design: Five different brands of implant were used in the study: Biofit (Castemaggiore, Italy), Bioner S. A. (Barcelona, Spain), 3i Biomet (Palm Beach, U. S. A.), BTI (Alava, Spain) and Nobel Biocare (Goteborg, Sweden), with standard 4.1 mm heads and external hexagons, and their respective machined prosthetic abutments. The implant-to-abutment fit/misfit was evaluated at four points (vestibular, lingual/palatine, mesial and distal) between implants and abutments of the same brand and different brands, with or without mechanical torque, using SEM micrographs at 5000X. Image analysis was performed using NIS-Elements software (Nikon Instruments Europe B. V.). Results: Before applying torque, vertical misfit (microgaps) of the different combinations tested varied between 1.6 and 5.4 microns and after applying torque, between 0.9 and 5.9 microns, an overall average of 3.46 +/- 2.96 microns. For manual assembly without the use of mechanical torque, the best results were obtained with the combination of the 3i implant and the BTI abutment. The Nobel implant and Nobel abutment, 3i-3i and BTI-BTI and the combination of 3i implant with BTI or Nobel abutment provided the best vertical fit when mechanical torque was applied. Conclusions: The vertical fits obtained were within the limits considered clinically acceptable. The application of mechanical torque improved outcomes. There is compatibility between implants and abutments of different brand and so their combination is a clinical possibility.
引用
收藏
页码:E332 / E336
页数:5
相关论文
共 50 条
  • [41] Accuracy of 3 different impression techniques for internal connection angulated implants
    Tsagkalidis, George
    Tortopidis, Dimitrios
    Mpikos, Pavlos
    Kaisarlis, George
    Koidis, Petros
    JOURNAL OF PROSTHETIC DENTISTRY, 2015, 114 (04): : 517 - 523
  • [42] Clinical outcomes of laser microtextured implants or abutments: A systematic review
    Carrigy, James
    Sharma, Ajay
    Perrotti, Vittoria
    Quaranta, Alessandro
    INTERNATIONAL JOURNAL OF ORAL IMPLANTOLOGY, 2021, 14 (02) : 141 - 154
  • [43] Fractured prosthetic abutments in osseointegrated implants:: a technical complication to cope with
    Luterbacher, S
    Fourmousis, I
    Lang, NP
    Brägger, U
    CLINICAL ORAL IMPLANTS RESEARCH, 2000, 11 (02) : 163 - 170
  • [44] In Vitro Evaluation of the Removal Force of Abutments in Frictional Dental Implants
    Zielak, Joao Cesar
    Rorbacker, Murilo
    Gomes, Rodrigo
    Yamashita, Celso
    Gonzaga, Carla Castiglia
    Giovanni, Allan Fernando
    JOURNAL OF ORAL IMPLANTOLOGY, 2011, 37 (05) : 519 - 523
  • [45] LIMITED EVIDENCE SUGGESTS THAT ZIRCONIA ABUTMENTS GENERATE LESS BLEEDING ON PROBING AROUND IMPLANTS COMPARED TO TITANIUM ABUTMENTS
    Geckili, Onur
    JOURNAL OF EVIDENCE-BASED DENTAL PRACTICE, 2018, 18 (04) : 346 - 348
  • [46] Accuracy of digitally coded healing abutments: A systematic review
    Talesara, Vaibhav
    Bennani, Vincent
    Aarts, John
    Ratnayake, Jithendra
    Khurshid, Zohaib
    Brunton, Paul
    SAUDI DENTAL JOURNAL, 2023, 35 (08) : 891 - 903
  • [47] Genomic Evaluation of Formed Biofilm on Dental Implants with Different Surface Treatments Associated with Zirconia or Titanium Abutments: An In Vitro Study
    dos Santos Neto, Otavio Marino
    do Nascimento, Cassio
    de Oliveira Silva, Thalisson Saymo
    Macedo, Ana Paula
    Ribeiro, Ricardo Faria
    Watababe, Ii-Sei
    Mardegan Issa, Joao Paulo
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2020, 35 (05) : 888 - 899
  • [48] Effect of the number of splinted abutments on the accuracy of zirconia copings
    Kim, Min-Wuk
    Kim, Jong-Yub
    Shim, June-Sung
    Kim, Sunjai
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 120 (05): : 790.e1 - 790.e7
  • [49] Comparing the auscultatory accuracy of health care professionals using three different brands of stethoscopes on a simulator
    Mehmood, Mansoor
    Abu Grara, Hazem L.
    Stewart, Joshua S.
    Khasawneh, Faisal A.
    MEDICAL DEVICES-EVIDENCE AND RESEARCH, 2014, 7 : 273 - 281
  • [50] In vitro scanning accuracy using different aids for multiple implants in the edentulous arch
    Kernen, Florian R.
    Recca, Mario
    Vach, Kirstin
    Nahles, Susanne
    Nelson, Katja
    Fluegge, Tabea, V
    CLINICAL ORAL IMPLANTS RESEARCH, 2022, 33 (10) : 1010 - 1020