Accuracy combining different brands of implants and abutments

被引:12
|
作者
Sola-Ruiz, Maria-Fernanda [1 ]
Selva-Otaolaurruchi, Eduardo [1 ]
Senent-Vicente, Gisela [1 ]
Gonzalez-de-Cossio, Ines [1 ]
Amigo-Borras, Vicente [2 ]
机构
[1] Univ Valencia, Fac Med & Dent, Dept Buccofacial Prosthet, E-46003 Valencia, Spain
[2] Univ Politecn Valencia, Dept Mech & Mat Engn, Valencia, Spain
来源
关键词
Vertical fit; implant; prosthetic abutment; combination; MARGINAL FIT; INTERFACE; MISFIT; PROSTHESES; STABILITY;
D O I
10.4317/medoral.18137
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To evaluate the vertical misfit between different brands of dental implants and prosthetic abutments, with or without mechanical torque, and to study their possible combination. Study design: Five different brands of implant were used in the study: Biofit (Castemaggiore, Italy), Bioner S. A. (Barcelona, Spain), 3i Biomet (Palm Beach, U. S. A.), BTI (Alava, Spain) and Nobel Biocare (Goteborg, Sweden), with standard 4.1 mm heads and external hexagons, and their respective machined prosthetic abutments. The implant-to-abutment fit/misfit was evaluated at four points (vestibular, lingual/palatine, mesial and distal) between implants and abutments of the same brand and different brands, with or without mechanical torque, using SEM micrographs at 5000X. Image analysis was performed using NIS-Elements software (Nikon Instruments Europe B. V.). Results: Before applying torque, vertical misfit (microgaps) of the different combinations tested varied between 1.6 and 5.4 microns and after applying torque, between 0.9 and 5.9 microns, an overall average of 3.46 +/- 2.96 microns. For manual assembly without the use of mechanical torque, the best results were obtained with the combination of the 3i implant and the BTI abutment. The Nobel implant and Nobel abutment, 3i-3i and BTI-BTI and the combination of 3i implant with BTI or Nobel abutment provided the best vertical fit when mechanical torque was applied. Conclusions: The vertical fits obtained were within the limits considered clinically acceptable. The application of mechanical torque improved outcomes. There is compatibility between implants and abutments of different brand and so their combination is a clinical possibility.
引用
收藏
页码:E332 / E336
页数:5
相关论文
共 50 条
  • [1] Comparison of Fracture Resistance and Fit Accuracy of Customized Zirconia Abutments with Prefabricated Zirconia Abutments in Internal Hexagonal Implants
    Park, Jong-Il
    Lee, Yoon
    Lee, Jin-Han
    Kim, Yu-Lee
    Bae, Ji-Myung
    Cho, Hye-Won
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2013, 15 (05) : 769 - 778
  • [2] Dimensional Tolerances and Assembly Accuracy of Dental Implants and Machined Versus Cast-On Abutments
    Malaguti, Giuliano
    Denti, Lucia
    Bassoli, Elena
    Franchi, Irene
    Bortolini, Sergio
    Gatto, Andrea
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2011, 13 (02) : 134 - 140
  • [3] Displacement and performance of abutments in narrow-diameter implants with different internal connections
    Jacobs, Nicholas
    Seghi, Robert
    Johnston, William M.
    Yilmaz, Burak
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (01): : 100 - 106
  • [4] Marginal bone levels at different Branemark implants single tooth abutments.
    Hermans, M
    Freund, N
    Daelemans, P
    Malevez, C
    JOURNAL OF DENTAL RESEARCH, 1997, 76 : 3302 - 3302
  • [5] ENDOSSEOUS IMPLANTS AS FIXED BRIDGE ABUTMENTS
    VISCIDO, AJ
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1969, 79 (06): : 1421 - &
  • [6] Discrepancy of abutments with their corresponding implants.
    Aguilar, JE
    Romanelli, HJ
    JOURNAL OF DENTAL RESEARCH, 1996, 75 (05) : 1061 - 1061
  • [7] Papillary fill response in single-tooth implants using abutments of different geometry
    Patil, Ratnadeep
    den Hartog, Laurens
    Dilbaghi, Anjali
    de Jong, Bart
    Kerdijk, Wouter
    Cune, Marco S.
    CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (12) : 1506 - 1510
  • [8] Longevity of different abutments placed on narrow diameter implants: Assessment of structural damage and loosening
    Lenz, Ulysses
    Santos, Renan Brandenburg
    Griggs, Jason Alan
    Estrela, Carlos
    dos Reis Bueno, Mike
    Porto, Olavo Cesar Lyra
    Della Bona, Alvaro
    DENTAL MATERIALS, 2024, 40 (09) : 1332 - 1340
  • [9] An In Vitro Evaluation of the Loosening of Different Interchangeable Abutments in Internal-Connection-Type Implants
    Park, Ji-Man
    Baek, Chang-Hyun
    Heo, Seong-Joo
    Kim, Seong-Kyun
    Koak, Jai-Young
    Kim, Shin-Koo
    Belser, Urs C.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (02) : 350 - 355
  • [10] Atraumatic intraoral scans and virtual hybrid casts for custom implant abutments and zirconia implants: Accuracy of the workflow
    Schubert, Oliver
    Edelhoff, Daniel
    Schweiger, Josef
    Gueth, Jan-Frederik
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 129 (06): : 920 - 929