Optimal fiducial points for pulse rate variability analysis from forehead and finger photoplethysmographic signals

被引:28
|
作者
Peralta, Elena [1 ,2 ]
Lazaro, Jesus [1 ,2 ,5 ]
Bailon, Raquel [1 ,2 ]
Marozas, Vaidotas [3 ,4 ]
Gil, Eduardo [1 ,2 ]
机构
[1] Univ Zaragoza, IIS Aragon, Aragon Inst Engn Res I3A, Biomed Signal Interpretat & Computat Simulat BSIC, Zaragoza, Spain
[2] CIBER BBN, Zaragoza, Spain
[3] Kaunas Univ Technol, Biomed Engn Inst, Kaunas, Lithuania
[4] Kaunas Univ Technol, Elect Engn Dept, Kaunas, Lithuania
[5] Univ Connecticut, Dept Biomed Engn, Storrs, CT USA
基金
欧盟地平线“2020”;
关键词
photoplethysmography (PPG); ECG; heart rate variability; pulse rate variability; autonomic nervous system; fiducial point selection; transmission and reflection modes; HEART-RATE-VARIABILITY; SHORT-TERM ANALYSIS; RELIABILITY; SURROGATE;
D O I
10.1088/1361-6579/ab009b
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Objective: The aim of this work is to evaluate and compare five fiducial points for the temporal location of each pulse wave from forehead and finger photoplethysmographic (PPG) pulse wave signals to perform pulse rate variability (PRV) analysis as a surrogate for heart rate variability (HRV) analysis. Approach: Forehead and finger PPG signals were recorded during a tilt-table test simultaneously with the electrocardiogram (ECG). Artefacts were detected and removed and five fiducial points were computed: apex, middle-amplitude and foot points of the PPG signal, apex point of the first derivative signal and the intersection point of the tangent to the PPG waveform at the apex of the derivative PPG signal and the tangent to the foot of the PPG pulse, defined as the intersecting tangents method. Pulse period (PP) time interval series were obtained from both PPG signals and compared with the RR intervals obtained from the ECG. HRV and PRV signals were estimated and classical time and frequency domain indices were computed. Main results: The middle-amplitude point of the PPG signal (n(M)), the apex point of the first derivative (n(A)*), and the tangent intersection point (n(T)) are the most suitable fiducial points for PRV analysis, resulting in the lowest relative errors estimated between PRV and HRV indices and higher correlation coefficients and reliability indices. Statistically significant differences according to the Wilcoxon test between PRV and HRV signals were found for the apex and foot fiducial points of the PPG, as well as the lowest agreement between RR and PP series according to Bland-Altman analysis. Hence, these signals have been considered less accurate for variability analysis. In addition, the relative errors are significantly lower for n(M) and n(A)(*) using Friedman statistics with a Bonferroni multiple-comparison test, and we propose that n(M) is the most accurate fiducial point. Based on our results, forehead PPG seems to provide more reliable information for a PRV assessment than finger PPG. Significance: The accuracy of the pulse wave detection depends on the morphology of the PPG. There is therefore a need to widely define the most accurate fiducial point for performing a PRV analysis under non-stationary conditions based on different PPG sensor locations and signal acquisition techniques.
引用
下载
收藏
页数:15
相关论文
共 50 条
  • [31] Wireless Photoplethysmographic Device for Heart Rate Variability Signal Acquisition and Analysis
    Reyes, Ivan
    Nazeran, Homer
    Franco, Mario
    Haltiwanger, Emily
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 2092 - 2095
  • [32] Pulse photoplethysmographic amplitude and heart rate variability during laparoscopic cholecystectomy: A prospective observational study
    Colombo, Riccardo
    Raimondi, Ferdinando
    Corona, Alberto
    Marchi, Andrea
    Borghi, Beatrice
    Pellegrin, Simone
    Bergomi, Paola
    Fossali, Tommaso
    Guzzetti, Stefano
    Porta, Alberto
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2017, 34 (08) : 526 - 533
  • [33] ROBUST BEAT-TO-BEAT DETECTION ALGORITHM FOR PULSE RATE VARIABILITY ANALYSIS FROM WRIST PHOTOPLETHYSMOGRAPHY SIGNALS
    Foroozan, Foroohar
    Mohan, Madhan
    Wu, Jian Shu
    2018 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING (ICASSP), 2018, : 2136 - 2140
  • [34] MEASURES OF FOREHEAD AND FINGER TEMPERATURE, FRONTALIS EMG, HEART-RATE AND FINGER PULSE AMPLITUDE DURING AND BETWEEN MIGRAINE HEADACHES
    MCARTHUR, DL
    COHEN, MJ
    HEADACHE, 1980, 20 (03): : 134 - 136
  • [35] Spectrum Filtering to Extract Pulse Rate Variability from Signals Recorded by Wearable Devices
    Prucnal, Monika A.
    Adamczyk, Krzysztof
    Polak, Adam G.
    BIOINFORMATICS AND BIOMEDICAL ENGINEERING, PT I, IWBBIO 2024, 2024, 14848 : 227 - 240
  • [36] Comparison of foot finding methods for deriving instantaneous pulse rates from photoplethysmographic signals
    Mathilde C. Hemon
    Justin P. Phillips
    Journal of Clinical Monitoring and Computing, 2016, 30 : 157 - 168
  • [37] Comparison of foot finding methods for deriving instantaneous pulse rates from photoplethysmographic signals
    Hemon, Mathilde C.
    Phillips, Justin P.
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2016, 30 (02) : 157 - 168
  • [38] Efficient Tracking of Heart Rate under Physical Exercise from Photoplethysmographic Signals
    Frigo, G.
    Fabris, M.
    Galli, A.
    Gambarin, F.
    Marsili, I. A.
    Narduzzi, C.
    Giorgi, G.
    2015 IEEE 1ST INTERNATIONAL FORUM ON RESEARCH AND TECHNOLOGIES FOR SOCIETY AND INDUSTRY (RTSI 2015) PROCEEDINGS, 2015,
  • [39] Estimation of Respiratory Rate From Photoplethysmographic Imaging Videos Compared to Pulse Oximetry
    Karlen, Walter
    Garde, Ainara
    Myers, Dorothy
    Scheffer, Cornie
    Ansermino, J. Mark
    Dumont, Guy A.
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2015, 19 (04) : 1331 - 1338
  • [40] Non-invasive Measurement of Pulse Rate Variability Signals by a PVDF Pulse Sensor
    Hu, Dun
    Zhou, Na
    Xie, Chenlei
    Gao, Lifu
    INTELLIGENT ROBOTICS AND APPLICATIONS, 2020, 12595 : 52 - 64