Optimal fiducial points for pulse rate variability analysis from forehead and finger photoplethysmographic signals

被引:28
|
作者
Peralta, Elena [1 ,2 ]
Lazaro, Jesus [1 ,2 ,5 ]
Bailon, Raquel [1 ,2 ]
Marozas, Vaidotas [3 ,4 ]
Gil, Eduardo [1 ,2 ]
机构
[1] Univ Zaragoza, IIS Aragon, Aragon Inst Engn Res I3A, Biomed Signal Interpretat & Computat Simulat BSIC, Zaragoza, Spain
[2] CIBER BBN, Zaragoza, Spain
[3] Kaunas Univ Technol, Biomed Engn Inst, Kaunas, Lithuania
[4] Kaunas Univ Technol, Elect Engn Dept, Kaunas, Lithuania
[5] Univ Connecticut, Dept Biomed Engn, Storrs, CT USA
基金
欧盟地平线“2020”;
关键词
photoplethysmography (PPG); ECG; heart rate variability; pulse rate variability; autonomic nervous system; fiducial point selection; transmission and reflection modes; HEART-RATE-VARIABILITY; SHORT-TERM ANALYSIS; RELIABILITY; SURROGATE;
D O I
10.1088/1361-6579/ab009b
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Objective: The aim of this work is to evaluate and compare five fiducial points for the temporal location of each pulse wave from forehead and finger photoplethysmographic (PPG) pulse wave signals to perform pulse rate variability (PRV) analysis as a surrogate for heart rate variability (HRV) analysis. Approach: Forehead and finger PPG signals were recorded during a tilt-table test simultaneously with the electrocardiogram (ECG). Artefacts were detected and removed and five fiducial points were computed: apex, middle-amplitude and foot points of the PPG signal, apex point of the first derivative signal and the intersection point of the tangent to the PPG waveform at the apex of the derivative PPG signal and the tangent to the foot of the PPG pulse, defined as the intersecting tangents method. Pulse period (PP) time interval series were obtained from both PPG signals and compared with the RR intervals obtained from the ECG. HRV and PRV signals were estimated and classical time and frequency domain indices were computed. Main results: The middle-amplitude point of the PPG signal (n(M)), the apex point of the first derivative (n(A)*), and the tangent intersection point (n(T)) are the most suitable fiducial points for PRV analysis, resulting in the lowest relative errors estimated between PRV and HRV indices and higher correlation coefficients and reliability indices. Statistically significant differences according to the Wilcoxon test between PRV and HRV signals were found for the apex and foot fiducial points of the PPG, as well as the lowest agreement between RR and PP series according to Bland-Altman analysis. Hence, these signals have been considered less accurate for variability analysis. In addition, the relative errors are significantly lower for n(M) and n(A)(*) using Friedman statistics with a Bonferroni multiple-comparison test, and we propose that n(M) is the most accurate fiducial point. Based on our results, forehead PPG seems to provide more reliable information for a PRV assessment than finger PPG. Significance: The accuracy of the pulse wave detection depends on the morphology of the PPG. There is therefore a need to widely define the most accurate fiducial point for performing a PRV analysis under non-stationary conditions based on different PPG sensor locations and signal acquisition techniques.
引用
下载
收藏
页数:15
相关论文
共 50 条
  • [21] Pulse Rate Variability Analysis for Discrimination of Sleep-Apnea-Related Decreases in the Amplitude Fluctuations of Pulse Photoplethysmographic Signal in Children
    Lazaro, Jesus
    Gil, Eduardo
    Maria Vergara, Jose
    Laguna, Pablo
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2014, 18 (01) : 240 - 246
  • [22] Pulse Transit Time - Fiducial Points Accuracy Determination as Examined by Means of Synthetic Signals
    Polinski, Artur
    Bujnowski, Adam
    Kocejko, Tomasz
    Wtorek, Jerzy
    2024 16TH INTERNATIONAL CONFERENCE ON HUMAN SYSTEM INTERACTION, HSI 2024, 2024,
  • [23] Spectral analysis of finger photoplethysmographic waveform variability in a model of mild to moderate haemorrhage
    Middleton P.M.
    Chan G.S.H.
    O'Lone E.
    Steel E.
    Carroll R.
    Celler B.G.
    Lovell N.H.
    Journal of Clinical Monitoring and Computing, 2008, 22 (5) : 343 - 353
  • [24] ECG PQRST complex detector and heart rate variability analysis using temporal characteristics of fiducial points
    Bae, Tae Wuk
    Kwon, Kee Koo
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2021, 66
  • [25] How accurate is pulse rate variability as an estimate of heart rate variability? A review on studies comparing photoplethysmographic technology with an electrocardiogram
    Schaefer, Axel
    Vagedes, Jan
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 166 (01) : 15 - 29
  • [26] Heart Rate Measurement from Motion Compensated Photoplethysmographic Signals
    Savaskan, Deniz Alp
    Mahanoglu, Alihan
    Soner, Burak
    Kholmatov, Alisher
    2020 28TH SIGNAL PROCESSING AND COMMUNICATIONS APPLICATIONS CONFERENCE (SIU), 2020,
  • [27] Accuracy of pulse rate variability parameters obtained from finger plethysmogram: A comparison with heart rate variability parameters obtained from ECG
    Kageyama, T
    Kabuto, M
    Kaneko, T
    Nishikido, N
    JOURNAL OF OCCUPATIONAL HEALTH, 1997, 39 (02) : 154 - 155
  • [28] Photoplethysmographic Measurements of Finger/Toe Arterial Pulse Waveforms and Their Compound Time Domain Analysis
    Huotari, Matti
    Maatta, Kari
    Kostamovaara, Juha
    15TH NORDIC-BALTIC CONFERENCE ON BIOMEDICAL ENGINEERING AND MEDICAL PHYSICS (NBC 2011), 2011, 34 : 207 - +
  • [29] The Pulse Wave Analysis of Normal Pregnancy: Investigating the Gestational Effects on Photoplethysmographic Signals
    Su, Fangming
    Li, Zhaoxi
    Sun, Xiurong
    Han, Nan
    Wang, Lei
    Luo, Xiaomin
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2014, 24 (01) : 209 - 219
  • [30] Evaluation of the coherence between the control of the variability of the photoplethysmographic pulse amplitude and the heart rate variability Coherence in PPGAV and HRV
    Martinez-Memije, R.
    Becerra-Luna, B.
    Infante, O.
    Ehrens, D.
    2017 IEEE INTERNATIONAL AUTUMN MEETING ON POWER, ELECTRONICS AND COMPUTING (ROPEC), 2017,