Signal amplitude and sensitivity of the Kelvin probe force microscopy

被引:11
|
作者
Ouisse, T
Martins, F
Stark, M
Huant, S
Chevrier, J
机构
[1] Univ Grenoble 1, Spectrometrie Phys Lab, F-38042 St Martin Dheres, France
[2] Univ Grenoble 1, Spectrometrie Phys Lab, F-38042 St Martin Dheres, France
[3] CNRS, UMR C5588, F-38042 St Martin Dheres, France
[4] CNRS, LEPES, F-38042 Grenoble 9, France
[5] European Synchrotron Radiat Facil, F-38043 Grenoble, France
关键词
D O I
10.1063/1.2168251
中图分类号
O59 [应用物理学];
学科分类号
摘要
When the tip-sample distance is small, Kelvin probe force microscopy is affected by parametric amplification. This is due to the fact that the electric force has two components; the higher one having a frequency exactly twice as high as the lower. The oscillation amplitude may substantially depart from what is usually expected. Those phenomena are analytically modeled and experimentally shown, and the optimal parameter values which must be used for voltage detection are established.
引用
收藏
页码:1 / 3
页数:3
相关论文
共 50 条
  • [31] Kelvin probe force microscopy of semiconductor surface defects
    Rosenwaks, Y
    Shikler, R
    Glatzel, T
    Sadewasser, S
    PHYSICAL REVIEW B, 2004, 70 (08) : 085320 - 1
  • [32] The role of the cantilever in Kelvin probe force microscopy measurements
    Elias, George
    Glatzel, Thilo
    Meyer, Ernst
    Schwarzman, Alex
    Boag, Amir
    Rosenwaks, Yossi
    BEILSTEIN JOURNAL OF NANOTECHNOLOGY, 2011, 2 : 252 - 260
  • [33] Kelvin probe force microscopy in ultra high vacuum using amplitude modulation detection of the electrostatic forces
    Sommerhalter, C
    Glatzel, T
    Matthes, TW
    Jäger-Waldau, A
    Lux-Steiner, MC
    APPLIED SURFACE SCIENCE, 2000, 157 (04) : 263 - 268
  • [34] Kelvin probe force microscopy in application to biomolecular films: Frequency modulation, amplitude modulation, and lift mode
    Moores, Brad
    Hane, Francis
    Eng, Lukas
    Leonenko, Zoya
    ULTRAMICROSCOPY, 2010, 110 (06) : 708 - 711
  • [35] Kelvin probe force microscopy imaging using carbon nanotube probe
    Takahashi, S
    Kishida, T
    Akita, S
    Nakayama, Y
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 2001, 40 (6B): : 4314 - 4316
  • [36] Inhomogeneous probe surface induced effect in Kelvin probe force microscopy
    Xu, Jie
    Bai, Gang
    Li, Jinze
    Li, Wei
    JOURNAL OF APPLIED PHYSICS, 2020, 127 (18)
  • [37] Investigation of the depletion layer by scanning capacitance force microscopy with Kelvin probe force microscopy
    Uruma, Takeshi
    Satoh, Nobuo
    Yamamoto, Hidekazu
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2016, 55 (08)
  • [38] Inhomogeneous probe surface induced effect in Kelvin probe force microscopy
    Xu, Jie
    Bai, Gang
    Li, Jinze
    Li, Wei
    Journal of Applied Physics, 2020, 127 (18):
  • [39] A Tutorial on Instrumental Parameters in Pulsed Force Kelvin Probe Force Microscopy
    Lozano-Onrubia, Guillermo
    Nazarov, Mikhail A.
    Walker, Gilbert C.
    LANGMUIR, 2024, 40 (48) : 25367 - 25380
  • [40] Torsional Harmonic Kelvin Probe Force Microscopy for High-Sensitivity Mapping of Surface Potential
    Zhang, Hao
    Gao, Haibo
    Geng, Junyuan
    Meng, Xianghe
    Xie, Hui
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2022, 69 (02) : 1654 - 1662