Absorbed Dose Calculations Using Mesh-based Human Phantoms And Monte Carlo Methods

被引:0
|
作者
Kramer, Richard [1 ]
机构
[1] Univ Fed Pernambuco, Dept Nucl Energy, BR-50740540 Recife, PE, Brazil
关键词
Radiation protection; human phantoms; organ absorbed dose; Monte Carlo method; ADULT HUMAN PHANTOMS; RADIATION PROTECTION DOSIMETRY; HIGH-ENERGY ELECTRONS; MU-CT IMAGES; SKELETAL DOSIMETRY; EXTERNAL EXPOSURE; MASH FEMALE; PHOTONS; SURFACES; SPONGIOSA;
D O I
10.1063/1.3608952
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
Health risks attributable to the exposure to ionizing radiation are considered to be a function of the absorbed or equivalent dose to radiosensitive organs and tissues. However, as human tissue cannot express itself in terms of equivalent dose, exposure models have to be used to determine the distribution of equivalent dose throughout the human body. An exposure model, be it physical or computational, consists of a representation of the human body, called phantom, plus a method for transporting ionizing radiation through the phantom and measuring or calculating the equivalent dose to organ and tissues of interest. The FASH2 (Female Adult meSH) and the MASH2 (Male Adult meSH) computational phantoms have been developed at the University of Pernambuco in Recife/Brazil based on polygon mesh surfaces using open source software tools and anatomical atlases. Representing standing adults, FASH2 and MASH2 have organ and tissue masses, body height and body mass adjusted to the anatomical data published by the International Commission on Radiological Protection for the reference male and female adult. For the purposes of absorbed dose calculations the phantoms have been coupled to the EGSnrc Monte Carlo code, which can transport photons, electrons and positrons through arbitrary media. This paper reviews the development of the FASH2 and the MASH2 phantoms and presents dosimetric applications for X-ray diagnosis and for prostate brachytherapy.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Validation of Monte Carlo dose planning calculations by epithermal beam: Dose distribution measurements in phantoms
    Carolan, MG
    Wallace, SA
    Allen, BJ
    Rosenfeld, AB
    Mathur, JN
    Meriaty, HA
    StecherRasmussen, F
    Moss, RL
    Raaijmakers, CPJ
    Konijnenberg, MW
    CANCER NEUTRON CAPTURE THERAPY, 1996, : 303 - 310
  • [22] Mesh-based Monte Carlo method using fast ray-tracing in Plucker coordinates
    Fang, Qianqian
    BIOMEDICAL OPTICS EXPRESS, 2010, 1 (01): : 165 - 175
  • [23] THE CALCULATION OF DOSE FROM EXTERNAL PHOTON EXPOSURES USING REFERENCE AND REALISTIC HUMAN PHANTOMS AND MONTE-CARLO METHODS
    WILLIAMS, G
    ZANKL, M
    ABMAYR, W
    VEIT, R
    DREXLER, G
    PHYSICS IN MEDICINE AND BIOLOGY, 1986, 31 (04): : 449 - 452
  • [24] Using Monte Carlo Method for estimation of Absorbed Dose in Mammography
    Rezaei, F. Salmani
    Feghhi, S. A.
    Aghamiri, S. M.
    Rezaei, A. Salmani
    Ebrahimi, A.
    PROCEEDINGS OF THE FOURTH INTERNATIONAL CONFERENCE OF MODELLING AND SIMULATION (ICMS2011), VOL 1, 2011, : 12 - 16
  • [25] Mesh-based Monte Carlo method for time-gated optical tomography
    Chen, Jin
    Intes, Xavier
    2011 IEEE 37TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE (NEBEC), 2011,
  • [26] A new method for the monitoring of female workers with in vivo measurements using deformable Mesh and NURBS phantoms and Monte Carlo calculations
    Farah, J.
    Broggio, D.
    Franck, D.
    RADIOPROTECTION, 2011, 46 (02) : 209 - 233
  • [27] Organ Dose Calculations Using ICRP Adult Voxel Phantoms and TRIPOLI-4 Monte Carlo Code
    Lee, Yi-Kang
    JOURNAL OF NUCLEAR ENGINEERING AND RADIATION SCIENCE, 2020, 6 (04):
  • [28] The Monte Carlo simulation of the absorbed dose in quartz
    Chen, Shaowen
    Liu, Xiaowei
    Zhang, Chunxiang
    Tang, Qiang
    RADIATION MEASUREMENTS, 2009, 44 (5-6) : 626 - 628
  • [29] Light transport modeling in highly complex tissues using the implicit mesh-based Monte Carlo algorithm
    Yuan, Yaoshen
    Yan, Shijie
    Fang, Qianqian
    BIOMEDICAL OPTICS EXPRESS, 2021, 12 (01) : 147 - 161
  • [30] Generalized mesh-based Monte Carlo for wide-field illumination and detection via mesh retessellation
    Yao, Ruoyang
    Intes, Xavier
    Fang, Qianqian
    BIOMEDICAL OPTICS EXPRESS, 2016, 7 (01): : 171 - 184