Marker-based validation of a biplane fluoroscopy system for quantifying foot kinematics

被引:15
|
作者
Iaquinto, Joseph M. [1 ,2 ]
Tsai, Richard [1 ]
Haynor, David R. [3 ]
Fassbind, Michael J. [1 ]
Sangeorzan, Bruce J. [1 ,4 ]
Ledoux, William R. [1 ,2 ,4 ]
机构
[1] VA Puget Sound Hlth Care Syst, Dept Vet Affairs, RR&D Ctr Excellence Limb Loss Prevent & Prosthet, Seattle, WA USA
[2] Univ Washington, Dept Mech Engn, Seattle, WA 98195 USA
[3] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
[4] Univ Washington, Dept Orthopaed & Sports Med, Seattle, WA 98195 USA
关键词
Biplane fluoroscopy; X-ray; Foot; Biomechanics; MODEL;
D O I
10.1016/j.medengphy.2013.08.013
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Introduction: Radiostereometric analysis has demonstrated its capacity to track precise motion of the bones within a subject during motion. Existing devices for imaging the body in two planes are often custom built systems: we present here the design and marker-based validation of a system that has been optimized to image the foot during gait. Methods: Mechanical modifications were made to paired BV Pulsera C-arms (Philips Medical Systems) to allow unfettered gait through the imaging area. Image quality improvements were obtained with high speed cameras and the correction of image distorting artifacts. To assess the system's accuracy, we placed beads at known locations throughout the imaging field, and used post processing software to calculate their apparent locations. Results: Distortion correction reduced overall RMS error from 6.56 mm to 0.17 mm. When tracking beads in static images a translational accuracy of 0.094 +/- 0.081 mm and rotational accuracy of 0.083 +/- 0.068 degrees was determined. In dynamic trials simulating speeds seen during walking, accuracy was 0.126 +/- 0.122 mm. Discussion: The accuracies and precisions found are within the reported ranges from other such systems. With the completion of marker-based validation, we look to model-based validation of the foot during gait. Published by Elsevier Ltd on behalf of IPEM.
引用
下载
收藏
页码:391 / 396
页数:6
相关论文
共 50 条
  • [31] Marker-based quadri-ocular tracking system for surgery
    He, Q.
    Wei, N.
    Li, B.
    Hu, C.
    Meng, M. Q. -H.
    IET COMPUTER VISION, 2012, 6 (05) : 435 - 441
  • [32] A Genetic Marker-Based Classification System for Acidity in Cider Apples
    Kumar, Shanthanu Krishna
    Wojtyna, Nathan Carey
    Dougherty, Laura
    Xu, Kenong
    Peck, Gregory
    HORTSCIENCE, 2020, 55 (09) : S324 - S325
  • [33] Reliable automatic calibration of a marker-based position tracking system
    Claus, D
    Fitzgibbon, AW
    WACV 2005: SEVENTH IEEE WORKSHOP ON APPLICATIONS OF COMPUTER VISION, PROCEEDINGS, 2005, : 300 - 305
  • [34] Marker-Based Reconstruction of the Kinematics of a Chain of Segments: A New Method That Incorporates Joint Kinematic Constraints
    Klous, Miriam
    Klous, Sander
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2010, 132 (07):
  • [35] Development and validation of a microsatellite marker-based method for tracing infections by Microsporum canis
    Pasquetti, Mario
    Peano, Andrea
    Soglia, Dominga
    Min, Anna Rita Molinar
    Pankewitz, Florian
    Ohst, Torsten
    Graeser, Yvonne
    JOURNAL OF DERMATOLOGICAL SCIENCE, 2013, 70 (02) : 123 - 129
  • [36] Evaluation and validation of tungsten fiducial marker-based image-guided radiotherapy
    Shahid, Wajeehah
    Mukhtar, Raheel
    Rizvi, Syed Faheem Askari
    Shahid, Samiah
    Iqbal, Muhammad Aamir
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2021, 7 (03):
  • [37] Comparison of kinematics between Theia markerless and conventional marker-based gait analysis in clinical patients
    Wren, Tishya A. L.
    Isakov, Pavel
    Rethlefsen, Susan A.
    GAIT & POSTURE, 2023, 104 : 9 - 14
  • [38] Kalman smoothing improves the estimation of joint kinematics and kinetics in marker-based human gait analysis
    De Groote, F.
    De Laet, T.
    Jonkers, I.
    De Schutter, J.
    JOURNAL OF BIOMECHANICS, 2008, 41 (16) : 3390 - 3398
  • [39] Marker-Based Method for Analyzing the Three-Dimensional Upper Body Kinematics of Violinists Reproducibility
    Wolf, Eduard
    Moller, Dirk
    Ballenberger, Nikolaus
    Morisse, Karsten
    Zalpour, Christoff
    MEDICAL PROBLEMS OF PERFORMING ARTISTS, 2022, 37 (03) : 176 - 191
  • [40] Comparison of lower limb and trunk kinematics between markerless and marker-based motion capture systems
    Perrott, Margaret A.
    Pizzari, Tania
    Cook, Jill
    McClelland, Jodie A.
    GAIT & POSTURE, 2017, 52 : 57 - 61