摘要
The main purpose of arc protection is the prevention of the initiation of an electric arc, and to decrease the emitted energy of the arc to the lowest possible level. If the hazard is not negligible, personal protective equipment must be used. In case of live-line maintenance (LLM) in high voltage (HV) systems, the use of personal protective equipment against arc is not common, but the chance of the development of an electric arc has to be evaluated in this case, too. During live work in HV systems, the possible appearance of an electric arc means extreme danger; due to the high power, the magnitude of the current of the arc may reach the range of several kiloampers. For this reason, the live-line personnel in the vicinity of the arc suffers extremely high levels of different kind of harmful loads. The main aim of this article is to investigate the possibility of the initialization of an electric arc during HV LLM and to analyze the proper ways of handling this kind of risk.
引用
收藏
页码:83 / 86
页数:4
相关论文
共 50 条
  • [41] SAFETY ASPECTS OF LIVE-LINE WORK METHODS
    REICHMAN, J
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1981, 100 (07): : 3478 - 3485
  • [42] An augmented virtual fixture to improve task performance in robot-assisted live-line maintenance
    Maddahi, Yaser
    Zareinia, Kourosh
    Sepehri, Nariman
    COMPUTERS & ELECTRICAL ENGINEERING, 2015, 43 : 292 - 305
  • [43] The Prospect of Live-Line Overhead Conductor Replacement
    Barthold, Lionel O.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2011, 26 (03) : 1418 - 1422
  • [44] Visual Live-Line Condition Monitoring of Composite Insulators
    Veerappan, Chithambaram A.
    Green, Peter R.
    Rowland, Simon M.
    2010 1ST INTERNATIONAL CONFERENCE ON APPLIED ROBOTICS FOR THE POWER INDUSTRY, 2010,
  • [45] Discharge of Air Gaps During Ground Potential Live-Line Work on Transmission Lines
    Gao, Jiachen
    Wang, Linong
    Li, Guanlin
    Fang, Yaqi
    Song, Bin
    Xiao, Bin
    Liu, Kai
    ELECTRIC POWER SYSTEMS RESEARCH, 2020, 187
  • [46] Haptic-Enabled Teleoperation of Base-Excited Hydraulic Manipulators Applied to Live-Line Maintenance
    Banthia, V.
    Maddahi, Y.
    Balakrishnan, S.
    Sepehri, N.
    2014 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS (IROS 2014), 2014, : 1222 - 1229
  • [47] On-line monitoring of OHL Conductor Temperature; Live-Line Installation
    Gal, Stelian Alexandru
    Oltean, Marius Nicolae
    Brabete, Lucian
    Rodean, Ioan
    Opincaru, Mircea
    2011 IEEE PES 12TH INTERNATIONAL CONFERENCE ON TRANSMISSION AND DISTRIBUTION CONSTRUCTION, OPERATION AND LIVE-LINE MAINTENANCE (ESMO), 2011,
  • [48] Evaluation of live-line maintenance techniques used on BPA reduced clearance 500kV lines
    Hildreth, J
    Gillies, D
    2004 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1 AND 2, 2004, : 445 - 450
  • [49] Live-Line Working of Non-Ceramic Insulators
    Carreira, A. J.
    2014 11TH INTERNATIONAL CONFERENCE ON LIVE MAINTENANCE (ICOLIM), 2014,
  • [50] Development of automatic cleaning robot for live-line insulators
    Park, Joon-Young
    Cho, Byung-Hak
    Byun, Seung-Hyun
    ESMO 2006-2006 IEEE 11TH INTERNATIONAL CONFERENCE ON TRANSMISSION & DISTRIBUTION CONSTRUCTION, OPERATION AND LIVE-LINE MAINTENANCE, 2006, : 66 - 72