A special risk during live-line maintenance

被引:0
|
作者
Halasz, Balint G. [1 ]
Nemeth, Balint [1 ]
Gocsei, Gabor [1 ]
机构
[1] Budapest Univ Technol & Econ, Egry Jozsef U 18, H-1111 Budapest, Hungary
关键词
live-line maintenance; arc protection; personal protective equipment;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The main purpose of arc protection is the prevention of the initiation of an electric arc, and to decrease the emitted energy of the arc to the lowest possible level. If the hazard is not negligible, personal protective equipment must be used. In case of live-line maintenance (LLM) in high voltage (HV) systems, the use of personal protective equipment against arc is not common, but the chance of the development of an electric arc has to be evaluated in this case, too. During live work in HV systems, the possible appearance of an electric arc means extreme danger; due to the high power, the magnitude of the current of the arc may reach the range of several kiloampers. For this reason, the live-line personnel in the vicinity of the arc suffers extremely high levels of different kind of harmful loads. The main aim of this article is to investigate the possibility of the initialization of an electric arc during HV LLM and to analyze the proper ways of handling this kind of risk.
引用
收藏
页码:83 / 86
页数:4
相关论文
共 50 条
  • [21] Development of the fully-automatic live-line maintenance robot - PhaseIII
    Takaoka, K
    Yokoyama, K
    Wakisako, H
    Yano, K
    Higashijima, K
    Murakami, S
    PROCEEDINGS OF THE 2001 IEEE INTERNATIONAL SYMPOSIUM ON ASSEMBLY AND TASK PLANNING (ISATP2001): ASSEMBLY AND DISASSEMBLY IN THE TWENTY-FIRST CENTURY, 2001, : 423 - 428
  • [22] Examination of clearances during high voltage live-line working
    Szabo, David
    Gocsei, Gabor
    Nemeth, Balint
    Richard, Cselko
    Racz, Levente
    2019 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2019, : 104 - 107
  • [23] WIRELESS CONTROL OF A TELEOPERATED HYDRAULIC MANIPULATOR WITH APPLICATION TOWARDS LIVE-LINE MAINTENANCE
    Maddahi, Yaser
    Sepehri, Nariman
    Liao, Stephen
    Fung, Wai-keung
    Hossain, Ekram
    PROCEEDINGS OF THE ASME/BATH SYMPOSIUM ON FLUID POWER AND MOTION CONTROL, 2013, 2014,
  • [24] Adaptive uneven illumination correction method for autonomous live-line maintenance robot
    Qiu, Yuze
    Chen, Yutao
    Zheng, Yuxiang
    Wang, Yahao
    Wu, Kai
    Wu, Shaolei
    Guo, Rui
    Zhao, Yuliang
    Dong, Erbao
    MULTIMEDIA TOOLS AND APPLICATIONS, 2023, 82 (15) : 23453 - 23481
  • [25] Adaptive uneven illumination correction method for autonomous live-line maintenance robot
    Yuze Qiu
    Yutao Chen
    Yuxiang Zheng
    Yahao Wang
    Kai Wu
    Shaolei Wu
    Rui Guo
    Yuliang Zhao
    Erbao Dong
    Multimedia Tools and Applications, 2023, 82 : 23453 - 23481
  • [26] UNILATERAL CONTROL OF TELEOPERATED HYDRAULIC MANIPULATORS FOR LIVE-LINE MAINTENANCE: COMPARATIVE STUDY
    Zareinia, Kourosh
    Maddahi, Yaser
    Sepehri, Nariman
    Olson, Tim
    Mueller, Wes
    INTERNATIONAL JOURNAL OF ROBOTICS & AUTOMATION, 2014, 29 (02): : 162 - 174
  • [27] Review on intelligent live-line maintenance technology applied on power transmission lines
    Hao Y.
    Liang W.
    Pan R.
    Luo B.
    Li L.
    Zhang F.
    Wang T.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2022, 42 (02): : 163 - 175
  • [28] Incomplete Faraday cage effect of helicopters used in platform live-line maintenance
    Cameron, GW
    Bodger, PS
    Woudberg, JJ
    IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 1998, 145 (02) : 145 - 148
  • [29] LIVE-LINE REPAIR WITH TOMCAT.
    Anon
    EPRI Journal, 1987, 12 (05): : 15 - 19
  • [30] Behavior Tree Based Dynamic Task Planning Method for Robotic Live-Line Maintenance
    Feng Jiabo
    Shi Lirong
    Liu Lei
    Zhang Weijun
    INTELLIGENT ROBOTICS AND APPLICATIONS (ICIRA 2022), PT III, 2022, 13457 : 673 - 685