Investigation of polycapillary half lenses for quantitative confocal micro-X-ray fluorescence analysis

被引:6
|
作者
Iro, Michael [1 ]
Ingerle, Dieter [1 ]
Radtke, Martin [2 ]
Buzanich, Ana Guilherme [2 ]
Kregsamer, Peter [1 ]
Streli, Christina [1 ]
机构
[1] TU Wien, Atominst, Stadionallee 2, A-1020 Vienna, Austria
[2] Bundesanstalt Mat Forsch & Prufung BAM, Richard Willstatter Str 11, D-12489 Berlin, Germany
关键词
polycapillary optics; confocal micro-XRF; X-ray fluorescence; 3D elemental analysis; X-ray optics;
D O I
10.1107/S1600577522009699
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The use of polycapillary optics in confocal micro-X-ray fluorescence analysis (CMXRF) enables the destruction-free 3D investigation of the elemental composition of samples. The energy-dependent transmission properties, concerning intensity and spatial beam propagation of three polycapillary half lenses, which are vital for the quantitative interpretation of such CMXRF measurements, are investigated in a monochromatic confocal laboratory setup at the Atominstitut of TU Wien, and a synchrotron setup on the BAMline beamline at the BESSY II Synchrotron, Helmholtz-Zentrum-Berlin. The empirically established results, concerning the intensity of the transmitted beam, are compared with theoretical values calculated with the polycap software package and a newly presented analytical model for the transmission function. The resulting form of the newly modelled energy-dependent transmission function is shown to be in good agreement with Monte Carlo simulated results for the complete energy regime, as well as the empirically established results for the energy regime between 6 keV and 20 keV. An analysis of possible fabrication errors was conducted via pinhole scans showing only minor fabrication errors in two of the investigated polycapillary optics. The energy-dependent focal spot size of the primary polycapillary was investigated in the laboratory via the channel-wise evaluation of knife-edge scans. Experimental results are compared with data given by the manufacturer as well as geometric estimations for the minimal focal spot size. Again, the resulting measurement points show a trend in agreement with geometrically estimated results and manufacturer data.
引用
收藏
页码:1376 / 1384
页数:9
相关论文
共 50 条
  • [31] Development of Portable Micro-X-ray Fluorescence Spectrometer
    Duan Z.
    Liu J.
    Jiang Q.
    Pan Q.
    Li R.
    Cheng L.
    Cheng, Lin (chenglin@bnu.edu.cn), 2018, Atomic Energy Press (52): : 2243 - 2248
  • [32] A new method of depth sensitive micro-X-ray fluorescence analysis
    Bjeoumikhov, A.
    Bjeoumikhova, S.
    Wedell, R.
    Gubzhokov, R.
    Margushev, Z.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2006, 248 (01): : 142 - 149
  • [33] Application of Micro-X-ray Fluorescence Analysis for the Characterization of Industrial Wastes
    Alba, Maria D.
    Aparicio, Patricia
    Benitez, Jose M.
    Castro, Miguel A.
    Diaz, Maria
    Mar Orta, M.
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2010, 49 (05) : 2348 - 2352
  • [34] Research on a laboratory monochromatic micro X-ray fluorescence spectrometer based on polycapillary X-ray lenses and flat crystal
    Wang, Xingyi
    Wu, Yiming
    Lin, Xiaoyan
    OPTIK, 2023, 282
  • [35] Investigation of a tabletop confocal micro x-ray fluorescence setup
    Lin Xiao-Yan
    Wang Zhi-Hong
    Chu Xue-Lian
    Sun Tian-Xi
    Ding Xun-Liang
    CHINESE PHYSICS LETTERS, 2007, 24 (12) : 3368 - 3370
  • [36] SIZE EFFECTS IN GLASS FRAGMENT IDENTIFICATION BY MICRO-X-RAY FLUORESCENCE ANALYSIS
    POZSGAI, I
    BARNA, A
    TOTH, P
    SCANNING, 1990, 12 (01) : 53 - 56
  • [37] Application of Three Dimensional Confocal Micro X-Ray Fluorescence Technology Based on Polycapillary X-Ray Lens in Analysis of Rock and Mineral Samples
    Li Fang-zuo
    Liu Zhi-guo
    Sun Tian-xi
    Yi Long-tao
    Zhao Wei-gang
    He Jia-lin
    Peng Song
    Wang Li-li
    Zhao Guang-cui
    Ding Xun-liang
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35 (09) : 2487 - 2491
  • [38] Detection of visible and latent fingerprints by micro-X-ray fluorescence
    Worley, Christopher G.
    Wiltshire, Sara S.
    Miller, Thomasin C.
    Havrilla, George J.
    Majidi, Vahid
    POWDER DIFFRACTION, 2006, 21 (02) : 136 - 139
  • [39] Confocal micro-X-ray fluorescence analysis as a new tool for the non-destructive study of the elemental distributions in pharmaceutical tablets
    Mazel, Vincent
    Reiche, Ina
    Busignies, Virginies
    Walter, Philippe
    Tchoreloff, Pierre
    TALANTA, 2011, 85 (01) : 556 - 561
  • [40] High-throughput screening with micro-x-ray fluorescence
    Havrilla, GJ
    Miller, TC
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (06):