Estrogens determination in wastewater samples by automatic in-syringe dispersive liquid-liquid microextraction prior silylation and gas chromatography

被引:36
|
作者
Gonzalez, Alba [1 ]
Avivar, Jessica [2 ]
Cerda, Victor [1 ]
机构
[1] Univ Balearic Isl, Dept Chem, Grp Analyt Chem Automat & Environm, E-07122 Palma De Mallorca, Spain
[2] Univ Balearic Isl, SL Spin, Sciware Syst, E-07193 Bunyola, Spain
关键词
In-syringe magnetic stirring-assisted dispersive liquid-liquid microextraction (in-syringe-MSA-DLLME); Gas chromatography (GC); Estrogens; Wastewater samples; Automation; MASS-SPECTROMETRY; IONIC LIQUID; 17-ALPHA-ETHINYLESTRADIOL; DERIVATIZATION; OPTIMIZATION; HORMONES; ESTRONE;
D O I
10.1016/j.chroma.2015.08.031
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new procedure for the extraction, preconcentration and simultaneous determination of the estrogens most used in contraception pharmaceuticals (estrone, 17 beta-estradiol, estriol, and 17 alpha-ethynylestradiol), cataloged as Contaminants of Emergent Concern by the Environmental Protection Agency of the United States (US-EPA), is proposed. The developed system performs an in-syringe magnetic stirring-assisted dispersive liquid-liquid microextraction (in-syringe-MSA-DLLME) prior derivatization and gas chromatography (GC-MS). Different extraction (carbon tetrachloride, ethyl acetate, chloroform and trichloroethylene) and disperser solvents (acetone, acetonitrile and methanol) were tested. Chloroform and acetone were chosen as extraction and disperser solvent, respectively, as they provided the best extraction efficiency. Then, a multivariate optimization of the extraction conditions was carried out. Derivatization conditions were also studied to ensure the conversion of the estrogens to their respective trimethylsilyl derivatives. Low LODs and LOQs were achieved, i.e. between 11 and 82 ng L-1, and 37 and 272 ng L-1, respectively. Good values for intra and inter-day precision were obtained (RSDs <= 7.06% and RSD <= 7.11%, respectively). The method was successfully applied to wastewater samples. (C) 2015 Elsevier B.V. All rights reserved.
引用
下载
收藏
页码:1 / 8
页数:8
相关论文
共 50 条
  • [21] In-syringe dispersive liquid-liquid microextraction based on the solidification of ionic liquids for the determination of benzoylurea insecticides in water and tea beverage samples
    Wang, Huazi
    Hu, Lu
    Li, Wanzhen
    Yang, Xiaoling
    Lu, Runhua
    Zhang, Sanbing
    Zhou, Wenfeng
    Gao, Haixiang
    Li, Jing
    TALANTA, 2017, 162 : 625 - 633
  • [22] Determination of priority phenolic pollutants exploiting an in-syringe dispersive liquid–liquid microextraction–multisyringe chromatography system
    Alba González
    Jessica Avivar
    Víctor Cerdà
    Analytical and Bioanalytical Chemistry, 2015, 407 : 2013 - 2022
  • [23] Dispersive Liquid-Liquid Microextraction Coupled with Gas Chromatography for the Determination of Orthochlorophenol in Environmental Water Samples
    Yang, Yingchun
    Sun, Qian
    Yi, Chongshu
    Ye, Zhixiang
    Mo, Li
    ADVANCES IN ENVIRONMENTAL SCIENCE AND ENGINEERING, PTS 1-6, 2012, 518-523 : 1379 - 1382
  • [24] One-step in-syringe ionic liquid-based dispersive liquid-liquid microextraction
    Cruz-Vera, Marta
    Lucena, Rafael
    Cardenas, Soledad
    Valcarcel, Miguel
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (37) : 6459 - 6465
  • [25] In-syringe-assisted dispersive liquid-liquid microextraction coupled to gas chromatography with mass spectrometry for the determination of six phthalates in water samples
    Clavijo, Sabrina
    del Rosario Brunetto, Maria
    Cerda, Victor
    JOURNAL OF SEPARATION SCIENCE, 2014, 37 (08) : 974 - 981
  • [26] Suitability of dispersive liquid-liquid microextraction for the in situ silylation of chlorophenols in water samples before gas chromatography with mass spectrometry
    Saraji, Mohammad
    Ghambari, Hoda
    JOURNAL OF SEPARATION SCIENCE, 2015, 38 (20) : 3552 - 3559
  • [27] Fully-Automated Fluorimetric Determination of Aluminum in Seawater by In-Syringe Dispersive Liquid-Liquid Microextraction Using Lumogallion
    Suarez, Ruth
    Horstkotte, Burkhard
    Duarte, Carlos M.
    Cerda, Victor
    ANALYTICAL CHEMISTRY, 2012, 84 (21) : 9462 - 9469
  • [28] DETERMINATION OF ESTROGENS IN WATER SAMPLES BY IONIC LIQUID-BASED DISPERSIVE LIQUID-LIQUID MICROEXTRACTION COMBINED WITH HIGH PERFORMANCE LIQUID CHROMATOGRAPHY
    Wu, Cui-Qin
    Chen, Di-Yun
    Feng, Yin-Si
    Deng, Hong-Mei
    Liu, Yong-Hui
    Zhou, Ai-Ju
    ANALYTICAL LETTERS, 2012, 45 (14) : 1995 - 2005
  • [29] In-syringe dispersive liquid-liquid microextraction using deep eutectic solvent as disperser: Determination of chromium (VI) in beverages
    Shishov, Andrey
    Terno, Pavel
    Moskvin, Leonid
    Bulatov, Andrey
    TALANTA, 2020, 206
  • [30] Determination of Estrogens in Water Samples Using Dispersive Liquid Liquid Microextraction and High Performance Liquid Chromatography
    Hadjmohammadi, Mohammad Reza
    Ghoreishi, Seyedeh Saboora
    ACTA CHIMICA SLOVENICA, 2011, 58 (04) : 765 - 771