Validation of a Multiresidue Analysis Method for 379 Pesticides in Human Serum Using Liquid Chromatography-Tandem Mass Spectrometry

被引:57
|
作者
Shin, Yongho [1 ,2 ]
Lee, Jonghwa [1 ,2 ]
Lee, Jiho [1 ,2 ]
Lee, Junghak [1 ,2 ]
Kim, Eunhye [1 ,2 ]
Liu, Kwang-Hyeon [3 ,4 ]
Lee, Hye Suk [5 ]
Kim, Jeong-Han [1 ,2 ]
机构
[1] Seoul Natl Univ, Dept Agr Biotechnol, Seoul 08826, South Korea
[2] Seoul Natl Univ, Res Inst Agr & Life Sci, Seoul 08826, South Korea
[3] Kyungpook Natl Univ, Coll Pharm, Plus KNU Multiomics Based Creat Drug Res Tea BK21, Daegu 41566, South Korea
[4] Kyungpook Natl Univ, Res Inst Pharmaceut Sci, Daegu 41566, South Korea
[5] Catholic Univ Korea, Coll Pharm, Bucheon Si 14662, Gyeonggi Do, South Korea
基金
新加坡国家研究基金会;
关键词
pesticide; multiresidue; intoxication; serum; QuEChERS; LC-MS/MS; QUECHERS SAMPLE PREPARATION; GAS-CHROMATOGRAPHY; ORGANOCHLORINE PESTICIDES; WHOLE-BLOOD; ORGANOPHOSPHORUS PESTICIDES; POLYCHLORINATED-BIPHENYLS; RAPID-DETERMINATION; RESIDUES; EXTRACTION; URINE;
D O I
10.1021/acs.jafc.8b00094
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
A screening method for simultaneous analysis of 379 pesticides in human serum was developed using liquid chromatography tandem mass spectrometry (LC-MS/MS). Electrospray ionization with positive/negative switching mode of LC-MS/MS was adopted, and scheduled multiple reaction monitoring for each target compound was established. The limit of quantitation was 10 ng/mL for 94.5% of the total pesticides, and the correlation coefficients of calibration were >= 0.990 for 93.9% of the pesticides. For the sample preparation, scaled-down QuEChERS were used. Serum (100 mu L) was extracted with acetonitrile (400 mu L), partitioned with magnesium sulfate (40 mg) and sodium chloride (10 mg), and the upper layer was used for analysis without further deanup steps. For the accuracy and precision tests, most of the pesticides showed excellent results in intra- and interday conditions. In the recovery tests at 10, 50, and 250 ng/mL, 85.8-91.8% of all target compounds satisfied the recovery range of 70-120% (relative standard deviation <= 20%).
引用
收藏
页码:3550 / 3560
页数:11
相关论文
共 50 条
  • [31] Validation of liquid chromatography-tandem mass spectrometry method for urinary cortisol
    Li, D.
    White, A.
    Kao, T.
    Pudek, M.
    CLINICAL BIOCHEMISTRY, 2008, 41 (14-15) : 1276 - 1277
  • [32] Development and Validation of Ion Chromatography-Tandem Mass Spectrometry-Based Method for the Multiresidue Determination of Polar Ionic Pesticides in Food
    Adams, Stuart
    Guest, Jonathan
    Dickinson, Michael
    Fussell, Richard J.
    Beck, Jonathan
    Schoutsen, Frans
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2017, 65 (34) : 7294 - 7304
  • [33] Development and validation of a liquid chromatography-tandem mass spectrometry method for the simultaneous analysis of androgens, estrogens, glucocorticoids and progestagens in human serum
    Iannone, Michele
    Dima, Anna Pia
    Sciarra, Francesca
    Botre, Francesco
    Isidori, Andrea M.
    BIOMEDICAL CHROMATOGRAPHY, 2022, 36 (05)
  • [34] Method Validation for Quantitative Analysis of Metribuzin in Wheat by Liquid Chromatography-Tandem Mass Spectrometry
    Hazra, Dipak Kumar
    Purkait, Aloke
    Raghuwanshi, Durgesh
    Murthy, K. Sri Rama
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2021, 59 (01) : 47 - 54
  • [35] Determination of Lamotrigine in Human Serum By Liquid Chromatography-Tandem Mass Spectrometry
    Lee, W.
    Yoon, S.
    Park, Y.
    Suh, B.
    Kwon, O. H.
    CLINICAL CHEMISTRY, 2009, 55 (06) : A261 - A261
  • [36] Measurement of tamsulosin in human serum by liquid chromatography-tandem mass spectrometry
    Upreti, Rita
    Homer, Natalie Z. M.
    Naredo, Gregorio
    Cobice, Diego F.
    Hughes, Katherine A.
    Stewart, Laurence H.
    Walker, Brian R.
    Andrew, Ruth
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 930 : 121 - 128
  • [37] Determination of Tirofiban in human serum by liquid chromatography-tandem mass spectrometry
    Oertel, R
    Köhler, A
    Koster, A
    Kirch, W
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 805 (01): : 181 - 185
  • [38] Quantitative determination of methylnaltrexone in human serum using liquid chromatography-tandem mass spectrometry
    Oswald, Stefan
    Schumacher, Gitta
    Siegmund, Werner
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 56 (05) : 1079 - 1084
  • [39] A multiresidue method using ion-trap gas chromatography-tandem mass spectrometry with or without derivatisation with pentafluorobenzylbromide for the analysis of pesticides in the atmosphere
    Scheyer, A
    Morville, S
    Mirabel, P
    Millet, M
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 381 (06) : 1226 - 1233
  • [40] Analysis of polar pesticides in rainwater in Denmark by liquid chromatography-tandem mass spectrometry
    Bossi, R
    Vejrup, KV
    Mogensen, BB
    Asman, WAH
    JOURNAL OF CHROMATOGRAPHY A, 2002, 957 (01) : 27 - 36