Kinetic analysis on rotating biological contactor treatment of organic matter

被引:1
|
作者
Li, Fang [1 ]
Qi, Zenglu [1 ]
机构
[1] Northeast Petr Univ, Civil Engn Coll, Daqing 163318, Heilongjiang, Peoples R China
来源
关键词
RBC; COD removal rate; kinetic equation;
D O I
10.4028/www.scientific.net/AMR.599.322
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper adopts a 3-stage rotating biological contactor (RBC), studies kinetic analysis on RBC treatment of organic matter.Water temperature 25 degrees C and hydraulic retention time (HRT) 5h, COD concentration of influent varies from about 400 to 700mg / L, the average COD removal rate is 85%. According to Monod and Michaelis-Menten formula, organic matter removal kinetics equation in the first stage of RBC can be catched. When DO >= 2mg/L, organic matter removal kinetic equation: U-1=7.02S(1)/(S-1+640.70), DO<2mg/L, organic matter removal kinetic equation: U-2=35.97S(2)/(S-2+4848.92). Where U is substrate removal rate of unit area of disc, S is the organic matter concentration of substrate. Some reference values of the equation are very useful for practical application of RBC.
引用
收藏
页码:322 / 325
页数:4
相关论文
共 50 条
  • [31] Membrane Filtration as Post-Treatment of Rotating Biological Contactor for Wastewater Treatment
    Waqas, Sharjeel
    Bilad, Muhammad Roil
    Huda, Nurul
    Harun, Noorfidza Yub
    Md Nordin, Nik Abdul Hadi
    Shamsuddin, Norazanita
    Wibisono, Yusuf
    Khan, Asim Laeeq
    Roslan, Jumardi
    SUSTAINABILITY, 2021, 13 (13)
  • [32] A Residual Analysis for the Removal of Biological Oxygen Demand through Rotating Biological Contactor
    Daudpoto, Muhmammad Rafique
    Talpur, Mir Ghulam Haider
    Shah, Feroz
    Khooharo, Aijaz
    MEHRAN UNIVERSITY RESEARCH JOURNAL OF ENGINEERING AND TECHNOLOGY, 2021, 40 (02) : 459 - 464
  • [33] Biodegradation of trichloroethylene in a rotating biological contactor
    Brar, SK
    Gupta, SK
    WATER RESEARCH, 2000, 34 (17) : 4207 - 4214
  • [34] Evaluating rotating biological contactor performance
    Stover, E.L.
    Kincannon, D.F.
    1976, 123 (03): : 88 - 91
  • [35] Mechanical redesign of the rotating biological contactor
    Mba, D
    Bannister, RH
    Findlay, GE
    WATER RESEARCH, 1999, 33 (18) : 3679 - 3688
  • [36] Startup simulation for a rotating biological contactor
    S. V. Pylnik
    I. G. Dueck
    Theoretical Foundations of Chemical Engineering, 2012, 46 : 72 - 79
  • [37] Startup Simulation for a Rotating Biological Contactor
    Pylnik, S. V.
    Dueck, I. G.
    THEORETICAL FOUNDATIONS OF CHEMICAL ENGINEERING, 2012, 46 (01) : 72 - 79
  • [38] Phenol biodegradation by rotating biological contactor
    Alemzadeh, I
    Vossoughi, F
    Houshmandi, M
    BIOCHEMICAL ENGINEERING JOURNAL, 2002, 11 (01) : 19 - 23
  • [39] SCALEUP IN ROTATING BIOLOGICAL CONTACTOR DESIGN
    WILSON, RW
    MURPHY, KL
    STEPHENSON, JP
    JOURNAL WATER POLLUTION CONTROL FEDERATION, 1980, 52 (03): : 610 - 621
  • [40] MODELING OF ROTATING BIOLOGICAL CONTACTOR SYSTEMS
    WU, YC
    SMITH, ED
    HUNG, YT
    BIOTECHNOLOGY AND BIOENGINEERING, 1980, 22 (10) : 2055 - 2064