Startup Simulation for a Rotating Biological Contactor

被引:2
|
作者
Pylnik, S. V. [1 ]
Dueck, I. G. [2 ]
机构
[1] Tomsk State Univ, Tomsk 634050, Russia
[2] Univ Erlangen Nurnberg, D-91052 Erlangen, Germany
关键词
BIOFILM; PERFORMANCE; REACTOR; SEWAGE;
D O I
10.1134/S0040579512010137
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A model for a rotating biological contactor is developed that takes into account the Michaelis-Menten kinetics, the submergence level of the disk, and its rotational speed. The aerobic nature of substrate processing and mass transfer between an aqueous medium and a biofilm are described. The model includes consideration of the erosion of the biofilm by flowing water. The variability of the biofilm thickness along the radius of the disk is taken into account. It is demonstrated how the steady-state characteristics of the bioreactor are reached under different bioreactor conditions.
引用
收藏
页码:72 / 79
页数:8
相关论文
共 50 条
  • [1] Startup simulation for a rotating biological contactor
    S. V. Pylnik
    I. G. Dueck
    [J]. Theoretical Foundations of Chemical Engineering, 2012, 46 : 72 - 79
  • [2] SIMULATION OF NITRIFICATION AND ITS DYNAMICS IN A ROTATING BIOLOGICAL CONTACTOR
    WATANABE, Y
    BRAVO, HE
    NISHIDOME, K
    [J]. WATER SCIENCE AND TECHNOLOGY, 1982, 14 (08) : 811 - 832
  • [3] A ROTATING BIOLOGICAL EXTENDED CONTACTOR
    KRZEMIENIEWSKI, M
    [J]. BIOLOGICAL WASTES, 1989, 29 (04): : 271 - 277
  • [4] NEW ROTATING BIOLOGICAL CONTACTOR
    不详
    [J]. EFFLUENT & WATER TREATMENT JOURNAL, 1978, 18 (10): : 537 - 537
  • [5] APPLYING THE ROTATING BIOLOGICAL CONTACTOR
    ANTONIE, RL
    [J]. WATER & SEWAGE WORKS, 1979, : R69 - &
  • [6] Biodegradation of trichloroethylene in a rotating biological contactor
    Brar, SK
    Gupta, SK
    [J]. WATER RESEARCH, 2000, 34 (17) : 4207 - 4214
  • [7] Mechanical redesign of the rotating biological contactor
    Mba, D
    Bannister, RH
    Findlay, GE
    [J]. WATER RESEARCH, 1999, 33 (18) : 3679 - 3688
  • [8] MODELING OF ROTATING BIOLOGICAL CONTACTOR SYSTEMS
    WU, YC
    SMITH, ED
    HUNG, YT
    [J]. BIOTECHNOLOGY AND BIOENGINEERING, 1980, 22 (10) : 2055 - 2064
  • [9] Phenol biodegradation by rotating biological contactor
    Alemzadeh, I
    Vossoughi, F
    Houshmandi, M
    [J]. BIOCHEMICAL ENGINEERING JOURNAL, 2002, 11 (01) : 19 - 23
  • [10] SCALEUP IN ROTATING BIOLOGICAL CONTACTOR DESIGN
    WILSON, RW
    MURPHY, KL
    STEPHENSON, JP
    [J]. JOURNAL WATER POLLUTION CONTROL FEDERATION, 1980, 52 (03): : 610 - 621