Online helium inventory monitoring of JLab cryogenic systems

被引:1
|
作者
Hasan, N. [1 ]
Knudsen, P. [2 ]
Wright, M. [2 ]
机构
[1] Thomas Jefferson Natl Accelerator Facil, Newport News, VA 23606 USA
[2] Michigan State Univ, Facil Rare Isotope Beams, E Lansing, MI 48824 USA
来源
关键词
D O I
10.1088/1757-899X/278/1/012113
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
There are five cryogenic plants at Jefferson Lab which support the LINAC, experiment hall end-stations and test facility. The majority of JLab's helium inventory, which is around 15 tons, is allocated in the LINAC cryo-modules, with the majority of the balance of helium distributed at the cryogenic-plant level mainly as stored gas and liquid for stable operation. Due to the organic evolution of the five plants and independent actions within the experiment halls, the traditional inventory management strategy suffers from rapid identification of potential leaks. This can easily result in losses many times higher than the normally accepted (average) loss rate. A real-time program to quickly identify potential excessive leakage was developed and tested. This program was written in MATLAB (c) for portability, easy diagnostics and modification. It interfaces directly with EPICS to access the cryogenic system state, and with and NIST REFPROP (c) for real fluid properties. This program was validated against the actual helium offloaded into the system. The present paper outlines the details of the inventory monitoring program, its validation and a sample of the achieved results.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] CRYOGENIC HELIUM COUNTER OF PARTICLES
    SAWICKI, JA
    NUCLEAR INSTRUMENTS & METHODS, 1978, 152 (2-3): : 577 - 578
  • [22] Commissioning and operational results of the 12 GeV helium compression system at JLab
    Knudsen, P.
    Ganni, V.
    Dixon, K.
    Norton, R.
    Creel, J.
    ADVANCES IN CRYOGENIC ENGINEERING, 2015, 101
  • [23] Classical Turbulence in Cryogenic Helium
    Niemela, Joseph J.
    VORTICES AND TURBULENCE AT VERY LOW TEMPERATURES, 2008, (501): : 259 - 289
  • [24] Engineering the Big Chill: The Story of JLab’s Central Helium Liquefier
    Catherine Westfall
    Physics in Perspective, 2014, 16 : 37 - 68
  • [25] Improvements to online distributed monitoring systems
    Wang, Bo
    Song, Ying
    Sun, Yuzhong
    Liu, Jun
    2016 IEEE TRUSTCOM/BIGDATASE/ISPA, 2016, : 1093 - 1100
  • [26] PerceMon: Online Monitoring for Perception Systems
    Balakrishnan, Anand
    Deshmukh, Jyotirmoy
    Hoxha, Bardh
    Yamaguchi, Tomoya
    Fainekos, Georgios
    RUNTIME VERIFICATION (RV 2021), 2021, 12974 : 297 - 308
  • [27] Online power monitoring for wearable systems
    Dorsey, JG
    Siewiorek, DR
    SIXTH INTERNATIONAL SYMPOSIUM ON WEARABLE COMPUTERS, PROCEEDINGS, 2002, : 137 - 138
  • [28] Scalable Online Monitoring of Distributed Systems
    Basin, David
    Gras, Matthieu
    Krstic, Srdan
    Schneider, Joshua
    RUNTIME VERIFICATION (RV 2020), 2020, 12399 : 197 - 220
  • [29] Online Metrics Prediction in Monitoring Systems
    Caneill, Matthieu
    De Palma, Noel
    Ait-Bachir, Ali
    Dine, Bastien
    Mokhtari, Rachid
    Cinar, Yagmur Gizem
    IEEE INFOCOM 2018 - IEEE CONFERENCE ON COMPUTER COMMUNICATIONS WORKSHOPS (INFOCOM WKSHPS), 2018, : 226 - 231
  • [30] Applicability of ASST-A helium refrigeration system for JLab End Station Refrigerator
    Hasan, N.
    Knudsen, P.
    Ganni, V.
    ADVANCES IN CRYOGENIC ENGINEERING, 2017, 278