Bead-based microfluidic immunoassay for diagnosis of Johne's disease

被引:19
|
作者
Wadhwa, Ashutosh [1 ]
Foote, Robert S. [2 ]
Shaw, Robert W. [2 ]
Eda, Shigetoshi [1 ]
机构
[1] Univ Tennessee, Ctr Wildlife Hlth, Dept Forestry Wildlife & Fisheries, Knoxville, TN 37996 USA
[2] Oak Ridge Natl Lab, Div Chem Sci, Oak Ridge, TN 37831 USA
关键词
Mycobacterium avium ssp paratuberculosis; Johne's disease; Microfluidics; Lab-on-a-chip; LINKED-IMMUNOSORBENT-ASSAY; PARATUBERCULOSIS; CATTLE;
D O I
10.1016/j.jim.2012.06.006
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Microfluidics technology offers a platform for development of point-of-care diagnostic devices for various infectious diseases. In this study, we examined whether serodiagnosis of Johne's disease (JD) can be conducted in a bead-based microfluidic assay system. Magnetic micro-beads were coated with antigens of the causative agent of JD, Mycobacterium avium subsp. paratuberculosis. The antigen-coated beads were incubated with serum samples of JD-positive or negative serum samples and then with a fluorescently-labeled secondary antibody (SAB). To confirm binding of serum antibodies to the antigen, the beads were subjected to flow cytometric analysis. Different conditions (dilutions of serum and SAB, types of SAB, and types of magnetic beads) were optimized for a large degree of differentiation between the JD-negative and JD-positive samples. Using the optimized conditions, we tested a well-classified set of 155 serum samples from JD-negative and JD-positive cattle by using the bead-based flow cytometric assay. Of 105 JD-positive samples, 63 samples (60%) showed higher antibody binding levels than a cut-off value determined by using antibody binding levels of JD-negative samples. In contrast, only 43-49 JD-positive samples showed higher antibody binding levels than the cut-off value when the samples were tested using commercially-available immunoassays. Microfluidic assays were performed by magnetically immobilizing a number of beads within a microchannel of a glass microchip and detecting antibody on the collected beads using laser-induced fluorescence. Antigen-coated magnetic beads treated with the bovine serum sample and fluorescently-labeled SAB were loaded into a microchannel to measure the fluorescence (reflecting level of antibody binding) on the beads in the microfluidic system. When the results of five bovine serum samples with the microfluidic system were compared to those analyzed with the flow cytometer, a high level of correlation (linear regression, r(2) = 0.994) was observed. In a further experiment, we magnetically immobilized antigen-coated beads in a microchannel, reacted the beads with serum and SAB in the channel, and detected antibody binding to the beads in the microfluidic system. A strong antibody binding in JD-positive serum was detected, whereas there was only negligible binding in negative control experiments. Our data suggest that the bead-based microfluidic system may form a basis for development of an on-site serodiagnosis of JD. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:196 / 202
页数:7
相关论文
共 50 条
  • [1] Microdrop analysis of a bead-based immunoassay
    Thomas, JH
    Ronkainen-Matsuno, NJ
    Farrell, S
    Halsall, HB
    Heineman, WR
    [J]. MICROCHEMICAL JOURNAL, 2003, 74 (03) : 267 - 276
  • [2] A novel bead-based fluorescence immunoassay for aldosterone
    Sun, Min
    Liu, Chao
    [J]. JOURNAL OF BIOMEDICAL RESEARCH, 2011, 25 (03): : 213 - 219
  • [3] Multiplexed bead-based immunoassay of four serum biomarkers for diagnosis of ovarian cancer
    Kim, Yong-Wan
    Bae, Su Mi
    Kim, In-Wook
    Liu, Hai-Bo
    Bang, Hyo Joo
    Chaturvedi, Pankaj Kumar
    Battogtokh, Gantumur
    Lim, Hyunsun
    Ahn, Woong Shick
    [J]. ONCOLOGY REPORTS, 2012, 28 (02) : 585 - 591
  • [4] A novel bead-based fluorescence immunoassay for aldosterone
    Min Sun
    [J]. The Journal of Biomedical Research, 2011, (03) : 213 - 219
  • [5] Microfluidic, bead-based assay: Theory and experiments
    Thompson, Jason A.
    Bau, Haim H.
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (02): : 228 - 236
  • [6] μFBI: A Microfluidic Bead-Based Immunoassay for Multiplexed Detection of Proteins from a μL Sample Volume
    Yu, Xiaobo
    Hartmann, Michael
    Wang, Quan
    Poetz, Oliver
    Schneiderhan-Marra, Nicole
    Stoll, Dieter
    Kazmaier, Cornelia
    Joos, Thomas O.
    [J]. PLOS ONE, 2010, 5 (10):
  • [7] Bead-based microfluidic immunoassays: The next generation
    Lim, C. T.
    Zhang, Y.
    [J]. BIOSENSORS & BIOELECTRONICS, 2007, 22 (07): : 1197 - 1204
  • [8] Bead-Based Digital Microfluidic Immunoassay for IL-1β Detection in Embryo Culture Medium
    Tseng, Hsueh-Yang
    Jiang, Yi-Ting
    Huang, Cheng-Yeh
    Lee, Meng-Shiue
    Hsu, Wensyang
    Yao, Da-Jeng
    [J]. 2017 IEEE 12TH INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS (NEMS), 2017, : 295 - 298
  • [9] Some key factors in a bead-based fluorescence immunoassay
    Kim, Young Jun
    Kim, Hye-Yoon
    Ah, Chil Seong
    Jung, Moon-Youn
    Park, Seon-Hee
    [J]. BIOCHIP JOURNAL, 2008, 2 (01) : 60 - 65
  • [10] Microelectrodes in bead-based sandwich immunoassay detection.
    Farrell, S
    Halsall, HB
    Heineman, WR
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2003, 225 : U124 - U124