A novel bead-based fluorescence immunoassay for aldosterone

被引:0
|
作者
Min Sun
机构
关键词
aldosterone; immunoassay; bead; extraction; multiplex;
D O I
暂无
中图分类号
R917 [药物分析];
学科分类号
100704 ;
摘要
Aldosterone quantification helps evaluate the rennin-angiotensin-aldosterone system. The new bead-based mul-tiplex platform has not been applied in aldosterone detection to achieve simultaneous measurements of multiple hormones. A new sensitive competitive bead immunoassay based on Luminex technology for detecting aldoster-one in small sample volumes was developed using two-antibody coupled beads and biotinylated aldosterone as tracer in combination with an extraction step. The assay was validated in human and mouse samples and exhibited a linear working range from 10 to 1,000 pg/mL. The assay was reproducible and precise with intra-assay coeffi-cient of variations (CVs) from 6.0% to 11.2%, inter-assay CVs from 8.0% to 13.0% and good recovery [(90-110)%] and linearity [(89-107)%]. Excellent correlation was found between this new assay and the reference method (r = 0.96, P < 0.000,1). The successful establishment of this assay provides high possibility for carrying out bead-based multiplex assay measuring aldosterone and other parameters simultaneously in one 50 μL sample so that the efficiency can be improved and precious samples can be saved.
引用
收藏
页码:213 / 219
页数:7
相关论文
共 50 条
  • [1] A novel bead-based fluorescence immunoassay for aldosterone
    Sun, Min
    Liu, Chao
    [J]. JOURNAL OF BIOMEDICAL RESEARCH, 2011, 25 (03): : 213 - 219
  • [2] A novel bead-based fluorescence immunoassay for aldosterone
    Min Sun Chao Liu Department of Endocrinology the First Affiliated Hospital of Nanjing Medical University Guangzhou Road Nanjing Jiangsu China
    [J]. Journal of Biomedical Research., 2011, 25 (03) - 219
  • [3] Some key factors in a bead-based fluorescence immunoassay
    Kim, Young Jun
    Kim, Hye-Yoon
    Ah, Chil Seong
    Jung, Moon-Youn
    Park, Seon-Hee
    [J]. BIOCHIP JOURNAL, 2008, 2 (01) : 60 - 65
  • [4] Microdrop analysis of a bead-based immunoassay
    Thomas, JH
    Ronkainen-Matsuno, NJ
    Farrell, S
    Halsall, HB
    Heineman, WR
    [J]. MICROCHEMICAL JOURNAL, 2003, 74 (03) : 267 - 276
  • [5] Optoelectrokinetically-Enabled Signal Enhancement for a Bead-Based FRET Fluorescence Immunoassay
    Chuang, Han-Sheng
    Wang, Kuan-Chih
    Hsieh, Dar-Bin
    Fu, Yong Qing
    [J]. PROCEEDINGS OF 2014 INTERNATIONAL SYMPOSIUM ON OPTOMECHATRONIC TECHNOLOGIES (ISOT), 2014, : 101 - 104
  • [6] Intensity Histogram-Based Reliable Image Analysis Method for Bead-Based Fluorescence Immunoassay
    Lee, Sanghyun
    Kim, Juyeong
    Bae, Pankee
    Lee, Sangmin
    Kim, Hojin
    [J]. BIOCHIP JOURNAL, 2024, 18 (01) : 137 - 145
  • [7] Intensity Histogram-Based Reliable Image Analysis Method for Bead-Based Fluorescence Immunoassay
    Sanghyun Lee
    Juyeong Kim
    Pankee Bae
    Sangmin Lee
    Hojin Kim
    [J]. BioChip Journal, 2024, 18 : 137 - 145
  • [8] A Novel Bead-Based Immunoassay for the Measurement of Heat Shock Proteins 27 and 70
    Njemini, Rose
    Verhaeghen, Katrijn
    Mets, Tony
    Weets, Ilse
    Bautmans, Ivan
    [J]. PATHOGENS, 2020, 9 (11): : 1 - 15
  • [9] Microelectrodes in bead-based sandwich immunoassay detection.
    Farrell, S
    Halsall, HB
    Heineman, WR
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2003, 225 : U124 - U124
  • [10] Bead-based spontaneous Raman codes for multiplex immunoassay
    Ma, Weiwei
    He, Caili
    Shen, Chengyue
    Zhang, Guihao
    Pan, Jun
    Tang, Yuchen
    Wang, Jinzhi
    Gao, Tingjuan
    [J]. ANALYTICA CHIMICA ACTA, 2024, 1316