Bead-based microfluidic immunoassay for diagnosis of Johne's disease

被引:19
|
作者
Wadhwa, Ashutosh [1 ]
Foote, Robert S. [2 ]
Shaw, Robert W. [2 ]
Eda, Shigetoshi [1 ]
机构
[1] Univ Tennessee, Ctr Wildlife Hlth, Dept Forestry Wildlife & Fisheries, Knoxville, TN 37996 USA
[2] Oak Ridge Natl Lab, Div Chem Sci, Oak Ridge, TN 37831 USA
关键词
Mycobacterium avium ssp paratuberculosis; Johne's disease; Microfluidics; Lab-on-a-chip; LINKED-IMMUNOSORBENT-ASSAY; PARATUBERCULOSIS; CATTLE;
D O I
10.1016/j.jim.2012.06.006
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Microfluidics technology offers a platform for development of point-of-care diagnostic devices for various infectious diseases. In this study, we examined whether serodiagnosis of Johne's disease (JD) can be conducted in a bead-based microfluidic assay system. Magnetic micro-beads were coated with antigens of the causative agent of JD, Mycobacterium avium subsp. paratuberculosis. The antigen-coated beads were incubated with serum samples of JD-positive or negative serum samples and then with a fluorescently-labeled secondary antibody (SAB). To confirm binding of serum antibodies to the antigen, the beads were subjected to flow cytometric analysis. Different conditions (dilutions of serum and SAB, types of SAB, and types of magnetic beads) were optimized for a large degree of differentiation between the JD-negative and JD-positive samples. Using the optimized conditions, we tested a well-classified set of 155 serum samples from JD-negative and JD-positive cattle by using the bead-based flow cytometric assay. Of 105 JD-positive samples, 63 samples (60%) showed higher antibody binding levels than a cut-off value determined by using antibody binding levels of JD-negative samples. In contrast, only 43-49 JD-positive samples showed higher antibody binding levels than the cut-off value when the samples were tested using commercially-available immunoassays. Microfluidic assays were performed by magnetically immobilizing a number of beads within a microchannel of a glass microchip and detecting antibody on the collected beads using laser-induced fluorescence. Antigen-coated magnetic beads treated with the bovine serum sample and fluorescently-labeled SAB were loaded into a microchannel to measure the fluorescence (reflecting level of antibody binding) on the beads in the microfluidic system. When the results of five bovine serum samples with the microfluidic system were compared to those analyzed with the flow cytometer, a high level of correlation (linear regression, r(2) = 0.994) was observed. In a further experiment, we magnetically immobilized antigen-coated beads in a microchannel, reacted the beads with serum and SAB in the channel, and detected antibody binding to the beads in the microfluidic system. A strong antibody binding in JD-positive serum was detected, whereas there was only negligible binding in negative control experiments. Our data suggest that the bead-based microfluidic system may form a basis for development of an on-site serodiagnosis of JD. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:196 / 202
页数:7
相关论文
共 50 条
  • [31] Integrated Immunomagnetic Bead-Based Microfluidic Chip for Exosomes Isolation
    Niu, Fuzhou
    Chen, Xifu
    Niu, Xuemei
    Cai, Yifan
    Zhang, Qingkui
    Chen, Tao
    Yang, Hao
    MICROMACHINES, 2020, 11 (05)
  • [32] A magnetic bead-based DNA extraction and purification microfluidic device
    Sayyed Mohamad Azimi
    Gavin Nixon
    Jeremy Ahern
    Wamadewa Balachandran
    Microfluidics and Nanofluidics, 2011, 11 : 157 - 165
  • [33] Bead-Based Microfluidic Sediment Analogues: Fabrication and Colloid Transport
    Guo, Yang
    Huang, Jingwei
    Xiao, Feng
    Yin, Xiaolong
    Chun, Jaehun
    Um, Wooyong
    Neeves, Keith B.
    Wu, Ning
    LANGMUIR, 2016, 32 (36) : 9342 - 9350
  • [34] Microfluidic system for serodiagnosis of Johne's disease
    Eda, S.
    Wadhwa, A.
    Bannantine, J. P.
    Scott, M. C.
    Shaw, R. W.
    Foote, R. S.
    JOURNAL OF DAIRY SCIENCE, 2010, 93 : 33 - 34
  • [35] Five-Antigen Fluorescent Bead-Based Assay for Diagnosis of Lyme Disease
    Embers, Monica E.
    Hasenkampf, Nicole R.
    Barnes, Mary B.
    Didier, Elizabeth S.
    Philipp, Mario T.
    Tardo, Amanda C.
    CLINICAL AND VACCINE IMMUNOLOGY, 2016, 23 (04) : 294 - 303
  • [36] Optimized magnetic bead-based immunoassay for automated detection of protein toxins
    Jung, Deok-Ho
    Min, Kyoungmi
    Jeon, Yongkwon
    Jang, Wonhee
    Kwon, Youngeun
    BIOCHIP JOURNAL, 2012, 6 (03) : 293 - 298
  • [37] Development of a rapid magnetic bead-based immunoassay for sensitive detection of zearalenone
    Zhao, Fengchun
    Shen, Qiang
    Wang, Huimin
    Han, Xiao
    Yang, Zhengyou
    FOOD CONTROL, 2017, 79 : 227 - 233
  • [38] A fast magnetic bead-based colorimetric immunoassay for the detection of tetrodotoxins in shellfish
    Campas, Monica
    Reverte, Jaume
    Rambla-Alegre, Maria
    Campbell, Katrina
    Gerssen, Arjen
    Diogene, Jorge
    FOOD AND CHEMICAL TOXICOLOGY, 2020, 140
  • [39] Optimized magnetic bead-based immunoassay for automated detection of protein toxins
    Deok-Ho Jung
    Kyoungmi Min
    Yongkwon Jeon
    Wonhee Jang
    Youngeun Kwon
    BioChip Journal, 2012, 6 : 293 - 298
  • [40] A HIGHLY SENSITIVE MULTIPLEXED BEAD-BASED IMMUNOASSAY FOR POTENTIAL MALARIA DIAGNOSTICS
    Clor, Julie
    Otto, Mary
    Mcdonald, John
    Jagannathan, Prasanna
    Greenhouse, Bryan
    Kakaru, Abel
    Mulry, James
    Greco, Beatrice
    Tyagarajan, Kamala
    AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2017, 97 (05): : 490 - 490