A Method for Redox Mapping by Confocal Micro-X-ray Fluorescence Imaging: Using Chromium Species in a Biochar Particle as an Example

被引:19
|
作者
Liu, Peng [1 ,2 ]
Ptacek, Carol J. [2 ]
Blowes, David W. [2 ]
Finfrock, Y. Zou [3 ,4 ]
Steinepreis, Mark [5 ]
Budimir, Filip [2 ]
机构
[1] China Univ Geosci, Sch Environm Studies, 388 Lumo Rd, Wuhan 430074, Hubei, Peoples R China
[2] Univ Waterloo, Dept Earth & Environm Sci, 200 Univ Ave W, Waterloo, ON N2L 3G1, Canada
[3] Argonne Natl Lab, Adv Photon Source, CLS APS Sect 20, 9700 S Cass Ave, Argonne, IL 60439 USA
[4] Canadian Light Source Inc, Sci Div, 44 Innovat Blvd, Saskatoon, SK S7N 2 V3, Canada
[5] Stantec Consulting Ltd, 100-300 Hagey Blvd, Waterloo, ON N2L 0A4, Canada
基金
中国国家自然科学基金; 加拿大自然科学与工程研究理事会;
关键词
HEXAVALENT CHROMIUM; BIOLOGICAL SAMPLES; SPECIATION; XANES; MECHANISMS; MICROFLUORESCENCE; SPECTROSCOPY; RESOLUTION; REDUCTION; STANDARDS;
D O I
10.1021/acs.analchem.8b05718
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Redox mapping of solid-phase particles has been used for speciation mapping of near-surface materials or within grains through the use of thin-sections without depth information. Here, a procedure is presented for data collection and processing of depth-dependent redox mapping within solid particles using confocal micro-X-ray fluorescence imaging (CMXRFI). The procedure was applied to a biochar particle that was reacted with Cr(VI)-spiked water. The total Cr distribution was first obtained at an above-edge energy of the K-edge, and showed that Cr was primarily distributed near the surface of the particle. Redox mapping was conducted at 33 representative energies and linear combination fitting (LCF) was performed for the 33 data points from each pixel. The results indicate Cr(III) is the primary species with fractions ranging from 0.6 to 1 and that this fraction is greater in the interior pixels of the particle than at the surface; in contrast, the Cr(VI) fraction is greater at the surface than for interior pixels. The results likely indicate Cr(VI) was first adsorbed and diffused into the biochar, and then reduced to Cr(III). With more Cr(VI) adsorption and the exceedance of the reduction potential of the biochar, remaining Cr(VI) was accumulated on the surface. The redox mapping method was validated by micro-XANES (X-ray absorption near-edge structure) and XPS (X-ray photoelectron spectroscopy) results. This demonstration indicates the developed method combined with CMXRFI can be used to delineate the distribution of different oxidation states of an element within an intact particle or layer.
引用
收藏
页码:5142 / 5149
页数:8
相关论文
共 50 条
  • [1] Characterization of chromium species and distribution during Cr(VI) removal by biochar using confocal micro-X-ray fluorescence redox mapping and X-ray absorption spectroscopy
    Liu, Peng
    Ptacek, Carol J.
    Blowes, David W.
    Finfrock, Y. Zou
    Liu, YingYing
    [J]. ENVIRONMENT INTERNATIONAL, 2020, 134
  • [2] Elemental Imaging of Nail Sample by Confocal Micro-X-ray Fluorescence Analysis
    Urata, Taisei
    Matsuyama, Tsugufumi
    Inoue, Fumiyuki
    Tsuji, Kouichi
    [J]. BUNSEKI KAGAKU, 2023, 72 (06) : 217 - 225
  • [3] Three dimensional subsurface elemental identification of minerals using confocal micro-X-ray fluorescence and micro-X-ray computed tomography
    Cordes, Nikolaus L.
    Seshadri, Srivatsan
    Havrilla, George J.
    Yuan, Xiaoli
    Feser, Michael
    Patterson, Brian M.
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2015, 103 : 144 - 154
  • [4] A method for calibrating the confocal volume of a confocal three-dimensional micro-x-ray fluorescence setup
    周鹏
    马欣然
    张爽
    孙天希
    刘志国
    [J]. Chinese Physics B, 2020, 29 (02) : 222 - 227
  • [5] A method for calibrating the confocal volume of a confocal three-dimensional micro-x-ray fluorescence setup
    Zhou, Peng
    Ma, Xin-Ran
    Zhang, Shuang
    Sun, Tian-Xi
    Liu, Zhi-Guo
    [J]. CHINESE PHYSICS B, 2020, 29 (02)
  • [6] A beam path-based method for attenuation correction of confocal micro-X-ray fluorescence imaging data
    Liu, Peng
    Ptacek, Carol J.
    Blowes, David W.
    Finfrock, Y. Zou
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2017, 32 (08) : 1582 - 1589
  • [7] Confocal micro-x-ray fluorescence spectrometer for light element analysis
    Smolek, S.
    Pemmer, B.
    Foelser, M.
    Streli, C.
    Wobrauschek, P.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (08):
  • [8] A monochromatic confocal micro-x-ray fluorescence (μXRF) spectrometer for the lab
    Ingerle, D.
    Swies, J.
    Iro, M.
    Wobrauschek, P.
    Streli, C.
    Hradil, K.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2020, 91 (12):
  • [9] Confocal micro-X-ray fluorescence analysis for difference identification of ceramic samples
    Mori, Kazuaki
    Hourai, Takayuki
    Matsuyama, Tsugufumi
    Zhuo, Shangjun
    Tsuji, Kouichi
    [J]. ANALYTICAL SCIENCES, 2024, 40 (03) : 367 - 373
  • [10] Confocal micro-X-ray fluorescence spectroscopy with a liquid metal jet source
    Bauer, Leona
    Lindqvist, Malcolm
    Foerste, Frank
    Lundstroem, Ulf
    Hansson, Bjoern
    Thiel, Markus
    Bjeoumikhova, Semfira
    Groetzsch, Daniel
    Malzer, Wolfgang
    Kanngiesser, Birgit
    Mantouvalou, Ioanna
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (09) : 1552 - 1558