Energy-subtraction Compton scatter camera design considerations: A Monte Carlo study of timing and energy resolution effects

被引:11
|
作者
Valentine, JD [1 ]
Bonnerave, C [1 ]
Rohe, RC [1 ]
机构
[1] UNIV CINCINNATI,DEPT NUCL MED,CINCINNATI,OH 45221
关键词
D O I
10.1109/23.596977
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An energy-subtraction Compton scatter camera (ESCSC) was previously proposed for medical imaging applications. This ESCSC consists of a primary detector system (silicon) and a secondary detector system (cadmium-zinc-telluride) for preferred detection of Compton scatter and photoelectric absorption interactions, respectively. To further evaluate the usefulness of this ESCSC for medical imaging, the following characteristics have been simulated: the random emission of gamma rays in time; detector timing, energy and spatial resolution; list mode data acquisition; and post-acquisition coincidence analysis. The resulting optimization of detector characteristics, data acquisition and analysis techniques, and administered activity is presented and discussed. One significant result of these simulations is that a localized activity of about 1.0 mCi allows for recovery of the majority of preferred events while eliminating the majority of interfering events when 10 and 50 ns FWHM timing resolutions for silicon and cadmium-zinc-telluride, respectively, are assumed. Consequently, the proposed ESCSC should be capable of acquiring data for administered activities similar to those used with current mechanically-collimated imaging cameras.
引用
下载
收藏
页码:1134 / 1139
页数:6
相关论文
共 50 条
  • [21] Energy Window Optimization Using Triple Energy Window Scatter Correction Method for In-111 SPECT Imaging: A SIMIND Monte Carlo Study
    Asmi, Hicham
    Bentayeb, Farida
    Bouzekraoui, Youssef
    Bonutti, Faustino
    Iranian Journal of Medical Physics, 2021, 18 (05) : 300 - 305
  • [22] Study by Monte-Carlo simulation of resolution improvement by energy filtering in Bio-TEM
    Suga, H
    Kouzuki, T
    Shimizu, R
    Kotera, M
    SURFACE AND INTERFACE ANALYSIS, 2002, 34 (01) : 657 - 659
  • [23] Design Guidelines for a Double Scattering Compton Camera for Prompt-γ Imaging During Ion Beam Therapy: A Monte Carlo Simulation Study
    Richard, M. -H.
    Chevallier, M.
    Dauvergne, D.
    Freud, N.
    Henriquet, P.
    Le Foulher, F.
    Letang, J. M.
    Montarou, G.
    Ray, C.
    Roellinghoff, F.
    Testa, E.
    Testa, M.
    Walenta, A. H.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (01) : 87 - 94
  • [24] A Monte Carlo study of high-energy photon transport in matter: application for multiple scattering investigation in Compton spectroscopy
    Brancewicz, Marek
    Itou, Masayoshi
    Sakurai, Yoshiharu
    JOURNAL OF SYNCHROTRON RADIATION, 2016, 23 : 244 - 252
  • [25] Dual-window scatter correction and energy window setting in cerebral blood flow SPECT:: a Monte Carlo study
    Gustafsson, A
    Ärlig, Å
    Jacobsson, L
    Ljungberg, M
    Wikkelsö, C
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (11): : 3431 - 3440
  • [26] Design concept of multi-energy gamma imaging with Compton camera in targeted alpha therapy: a simulation study
    Feng, Yuemeng
    Sabet, Hamid
    JOURNAL OF NUCLEAR MEDICINE, 2023, 64
  • [27] Study and design of an energy monitoring device for an industrial electron accelerator using Monte Carlo simulation
    Yuan, Jushigang
    Zhang, Gefei
    Pang, Shiqiang
    Chen, Taiyan
    Huang, Jiang
    RADIATION PHYSICS AND CHEMISTRY, 2023, 206
  • [28] Effect of x-ray energy dispersion in digital subtraction imaging at the iodine K-edge -: A Monte!Carlo study
    Prino, F.
    Ceballos, C.
    Cabal, A.
    Sarnelli, A.
    Gambaccini, M.
    Ramello, L.
    MEDICAL PHYSICS, 2008, 35 (01) : 13 - 24
  • [29] MONTE-CARLO STUDY OF THE LIGHT YIELD, UNIFORMITY AND ENERGY RESOLUTION OF ELECTROMAGNETIC CALORIMETERS WITH A FIBER READOUT SYSTEM
    LABARGA, L
    ROS, E
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 249 (2-3): : 228 - 234
  • [30] Monte Carlo design study for in vivo bone aluminum measurement using a low energy accelerator beam
    Pejovic-Milic, A
    Arnold, ML
    McNeill, FE
    Chettle, DR
    APPLIED RADIATION AND ISOTOPES, 2000, 53 (4-5) : 657 - 664