Low-dose CT coronary angiography in the step-and-shoot mode: diagnostic performance

被引:213
|
作者
Scheffel, H. [1 ]
Alkadhi, H. [1 ]
Leschka, S. [1 ]
Plass, A. [2 ]
Desbiolles, L. [1 ]
Guber, I. [2 ]
Krauss, T. [1 ]
Gruenenfelder, J. [2 ]
Genoni, M. [2 ]
Luescher, T. F. [3 ]
Marincek, B. [1 ]
Stolzmann, P. [1 ]
机构
[1] Univ Zurich Hosp, Inst Diag Radiol, CH-8091 Zurich, Switzerland
[2] Univ Zurich Hosp, Cardiovasc Surg Clin, CH-8091 Zurich, Switzerland
[3] Univ Zurich Hosp, Ctr Cardiovasc, CH-8091 Zurich, Switzerland
关键词
D O I
10.1136/hrt.2008.149971
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To investigate the performance of low-dose, dual-source computed tomography (DSCT) coronary angiography in the step-and-shoot (SAS) mode for the diagnosis of significant coronary artery stenoses in comparison with conventional coronary angiography (CCA). Design, setting and patients: Prospective, single-centre study conducted in a referral centre enrolling 120 patients (71 men, mean (SD) age 68 (9) years, mean (SD) body mass index 26.2 (3.2) kg/m(2)). All study participants underwent DSCT in the SAS mode and CCA within 14 days. Twenty-seven patients were given intravenous beta blockers for heart rate reduction before CT. Patients were excluded if a target heart rate <= 70 bpm could not be achieved by beta blockers or when the patients were in non-sinus rhythm. Two blinded readers independently evaluated coronary artery segments for assessability and for the presence of significant (>50%) stenoses. Sensitivity, specificity, negative (NPV) and positive predictive values (PPV) were determined, with CCA being the standard of reference. Radiation dose values were calculated. Results: DSCT coronary angiography in the SAS mode was successfully performed in all 120 patients. Mean (SD) heart rate during scanning was 59 (6) bpm (range 44-69). 1773/1803 coronary segments (98%) were depicted with a diagnostic image quality in 109/120 patients (91%). The overall patient-based sensitivity, specificity, PPV and NPV for the diagnosis of significant stenoses were 100%, 93%, 94% and 100%, respectively. The mean (SD) effective dose of the CT protocol was 2.5 (0.8) mSv (range 1.2-4.4). Conclusions: DSCT coronary angiography in the SAS mode allows, in selected patients with a regular heart rate, the accurate diagnosis of significant coronary stenoses at a low radiation dose.
引用
收藏
页码:1132 / 1137
页数:6
相关论文
共 50 条
  • [1] Dual-source CT in step-and-shoot mode: Noninvasive coronary angiography with low radiation dose
    Stolzmann, Paul
    Leschka, Sebastian
    Scheffel, Hans
    Krauss, Tobias
    Desbiolles, Lotus
    Plass, Andre
    Genoni, Michele
    Flohr, Thomas G.
    Wildermuth, Simon
    Marincek, Borut
    Alkadhi, Hatem
    [J]. RADIOLOGY, 2008, 249 (01) : 71 - 80
  • [2] Low-dose, 128-slice, dual-source CT coronary angiography: accuracy and radiation dose of the high-pitch and the step-and-shoot mode
    Alkadhi, Hatem
    Stolzmann, Paul
    Desbiolles, Lotus
    Baumueller, Stephan
    Goetti, Robert
    Plass, Andre
    Scheffel, Hans
    Feuchtner, Gudrun
    Falk, Volkmar
    Marincek, Borut
    Leschka, Sebastian
    [J]. HEART, 2010, 96 (12) : 933 - 938
  • [3] Low-dose "step-and-shoot" CT in patients with atrial fibrillation: Is simultaneous assessment of the left atrium and coronary arteries feasible?
    Maurovich-Horvat, P.
    Karolyi, M.
    Kolossvary, M.
    O'Connor, R.
    Szeplaki, G.
    Bartykowszki, A.
    Geller, L.
    Merkely, B.
    [J]. EUROPEAN HEART JOURNAL, 2013, 34 : 972 - 972
  • [4] Diagnostic performance of low-radiation-dose and low-contrast-dose (double low-dose) coronary CT angiography for coronary artery stenosis
    Zhang, Wei
    Ba, Zhaogui
    Wang, Zhenqiang
    Lv, Huaying
    Zhao, Jun
    Zhang, Yonghua
    Zhang, Feixue
    Song, Lei
    [J]. MEDICINE, 2018, 97 (34)
  • [5] Prognostic performance of low-dose coronary CT angiography with prospective ECG triggering
    Buechel, Ronny R.
    Pazhenkottil, Aju P.
    Herzog, Bernhard A.
    Brueckner, Michael
    Nkoulou, Rene
    Ghadri, Jelena R.
    Kueest, Silke M.
    Wyss, Christophe A.
    Husmann, Lars
    Kaufmann, Philipp A.
    [J]. HEART, 2011, 97 (17) : 1385 - 1390
  • [6] Low-dose CT coronary angiography for the prediction of myocardial ischaemia
    Stolzmann, Paul
    Donati, Olivio F.
    Scheffel, Hans
    Azemaj, Naim
    Baumueller, Stephan
    Plass, Andre
    Kozerke, Sebastian
    Leschka, Sebastian
    Gruenenfelder, Juerg
    Boesiger, Peter
    Marincek, Borut
    Alkadhi, Hatem
    [J]. EUROPEAN RADIOLOGY, 2010, 20 (01) : 56 - 64
  • [7] Low-dose CT coronary angiography for the prediction of myocardial ischaemia
    Paul Stolzmann
    Olivio F. Donati
    Hans Scheffel
    Naim Azemaj
    Stephan Baumueller
    André Plass
    Sebastian Kozerke
    Sebastian Leschka
    Jürg Grünenfelder
    Peter Boesiger
    Borut Marincek
    Hatem Alkadhi
    [J]. European Radiology, 2010, 20 : 56 - 64
  • [8] Lowering radiation dose for integrated assessment of coronary morphology and physiology: First experience with step-and-shoot CT angiography in a rubidium 82 PET-CT protocol
    Javadi M.
    Mahesh M.
    McBride G.
    Voicu C.
    Epley W.
    Merrill J.
    Bengel F.M.
    [J]. Journal of Nuclear Cardiology, 2008, 15 (6) : 783 - 790
  • [9] Lowering radiation dose for integrated assessment of coronary morphology and physiology: First experience with step-and-shoot CT angiography in a rubidium 82 PET-CT protocol
    Javadi, Mehrbod
    Mahesh, Mahadevappa
    McBride, Gerald
    Voicu, Corina
    Epley, William
    Merrill, Jennifer
    Bengel, Frank M.
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2008, 15 (06) : 783 - 790
  • [10] Meta-analysis: diagnostic accuracy of coronary CT angiography with prospective ECG gating based on step-and-shoot, Flash and volume modes for detection of coronary artery disease
    Yang, Linfeng
    Zhou, Tao
    Zhang, Ruijie
    Xu, Lin
    Peng, Zhaohui
    Ding, Juan
    Wang, Sen
    Li, Min
    Sun, Gang
    [J]. EUROPEAN RADIOLOGY, 2014, 24 (10) : 2345 - 2352