Molar mass measurement of a 28Si-enriched silicon crystal with high precision secondary ion mass spectrometry (SIMS)

被引:2
|
作者
Gao, Yu-ya [1 ]
Ren, Tong-xiang [1 ]
Williams, Ian S. [2 ]
Ireland, Trevor R. [2 ,3 ]
Long, Tao [4 ]
Rienitz, Olaf [5 ]
Pramann, Axel [5 ]
Wang, Song [1 ]
Song, Pan-shu [1 ]
Wang, Jun [1 ]
机构
[1] Natl Inst Metrol, Chem Metrol Div, Beijing 1229, Peoples R China
[2] Australian Natl Univ, Res Sch Earth Sci, Canberra, ACT 0200, Australia
[3] Univ Queensland, Sch Earth & Environm Sci, Brisbane, Qld 4072, Australia
[4] Chinese Acad Geol Sci, Beijing SHRIMP Ctr, Inst Geol, Beijing 102206, Peoples R China
[5] Phys Tech Bundesanstalt, D-38116 Braunschweig, Germany
基金
国家重点研发计划;
关键词
AVOGADRO CONSTANT;
D O I
10.1039/d2ja00229a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Several highly-enriched Si-28 crystals were produced to enable a better determination of the Avogadro constant through removing the uncertainty associated with the abundance determination of the minor isotopes Si-29 and Si-30. Previous determinations have used inductively coupled plasma mass spectrometry (ICP-MS), which typically requires rather large amounts of material and complex chemical pre-treatment. A secondary ion mass spectrometry (SIMS) protocol for ultra-high precision and accuracy Si isotope measurements of a Si-28-enriched crystal (AVO28) was developed in this study using a reverse-geometry ion microprobe SHRIMP RG. An approximate to 8 nA primary beam intensity was used to sputter the Si-28-enriched crystal. Secondary ions were measured on a combination of Faraday cup, for Si-28(+), and electron multiplier for the low abundance Si-29(+) and Si-30(+) signals respectively. The secondary ion intensities and isotope ratios were determined following baseline correction, gain correction, tailing correction and instrumental mass fractionation correction. An internal precision of +/- 0.000016 (2 s(m)) and external precision (reproducibility) of +/- 0.000043 (2 s) were achieved for Si-29/Si-28 of spot-to-spot analyses on natural silicon (WASO 04). The Si isotope ratios of AVO28 are n(Si-29)/n(Si-28) = 0.00004107(63) mol mol(-1) and n(Si-30)/n(Si-28) = 0.00000107(4) mol mol(-1), 2 s, respectively. As a result, an average molar mass of the AVO28 material was determined to be 27.97696972 g mol(-1) with an associated relative standard uncertainty of 1.3 x 10(-8) (k = 1). This newly developed SIMS method avoids the complex chemical pre-treatment and the molar mass was in good agreement (similar to 10(-8)) with solution multi-collection-ICP-MS results.
引用
收藏
页码:2546 / 2555
页数:10
相关论文
共 50 条
  • [41] The use of secondary ion mass spectrometry (SIMS) to evaluate internal contamination
    Amaral, A
    Labéjof, L
    Escaig, F
    Galle, P
    CELLULAR AND MOLECULAR BIOLOGY, 2002, 48 (05) : 557 - 562
  • [42] DETECTION AND IDENTIFICATION OF STEROIDS BY SECONDARY ION MASS-SPECTROMETRY (SIMS)
    SICHTERMANN, W
    EICKE, A
    JUNACK, M
    BENNINGHOVEN, A
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1982, 311 (04): : 410 - 411
  • [43] THE DEVELOPMENT OF SECONDARY ION MASS-SPECTROMETRY (SIMS) - A RETROSPECTIVE - COMMENT
    GRIES, WH
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1986, 70 (01): : 115 - 115
  • [44] Depth Profiling and Melting of Nanoparticles in Secondary Ion Mass Spectrometry (SIMS)
    Yang, Li
    Seah, Martin P.
    Gilmore, Ian S.
    Morris, Richard J. H.
    Dowsett, Mark G.
    Boarino, Luca
    Sparnacci, Katia
    Laus, Michele
    JOURNAL OF PHYSICAL CHEMISTRY C, 2013, 117 (31): : 16042 - 16052
  • [45] THE HYDRATION OF CEMENT STUDIED BY SECONDARY ION MASS-SPECTROMETRY (SIMS)
    GERHARD, W
    NAGELE, E
    CEMENT AND CONCRETE RESEARCH, 1983, 13 (06) : 849 - 860
  • [46] SOME FACTORS AFFECTING THE QUANTIFICATION OF CARBON AND OXYGEN IN SILICON BY SECONDARY ION MASS-SPECTROMETRY (SIMS)
    NAKADA, Y
    KOUTSUKA, T
    MINE, K
    SUGA, H
    JOURNAL OF THE JAPAN INSTITUTE OF METALS, 1992, 56 (10) : 1174 - 1178
  • [47] Characterization of amorphous silicon by secondary ion mass spectrometry
    Li, YP
    Wang, S
    Lin, XF
    Wei, LC
    Amorphous and Nanocrystalline Silicon Science and Technology-2005, 2005, 862 : 439 - 444
  • [48] The application of secondary ion mass spectrometry (SIMS) to the study of high temperature proton conductors (HTPC)
    DeSouza, RA
    Kilner, JA
    Jeynes, C
    SOLID STATE IONICS, 1997, 97 (1-4) : 409 - 419
  • [49] HIGH-PERFORMANCE SECONDARY ION MASS-SPECTROMETRY (SIMS) FOR THE CHARACTERIZATION OF HYDROGEN IN METALS
    BLATTNER, RJ
    DELINE, VR
    EVANS, CA
    JOURNAL OF METALS, 1981, 33 (09): : A29 - A29
  • [50] High depth resolution secondary ion mass spectrometry (SIMS) analysis of Si1-xGex:C HBT structures
    Lu, S
    Kottke, M
    Zollner, S
    Chen, W
    CHARACTERIZATION AND METROLOGY FOR ULSI TECHNOLOGY 2000, INTERNATIONAL CONFERENCE, 2001, 550 : 672 - 676