New approach for particulate exposure monitoring: determination of inhaled particulate mass by 24 h real-time personal exposure monitoring

被引:6
|
作者
Yoon, Chungsik [1 ]
Ryu, Kyongnam [1 ]
Kim, Junghyun [1 ]
Lee, Kiyoung [1 ]
Park, Donguk [2 ]
机构
[1] Seoul Natl Univ, Grad Sch Publ Hlth, Dept Environm Hlth, Seoul 151742, South Korea
[2] Korea Natl Open Univ, Dept Environm Hlth, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
environmental monitoring; inhalation exposure; particulate matter; personal exposure; AIR-POLLUTION; INFORMATION-SYSTEMS; ACTIVITY-PATTERNS; INDOOR; HEALTH; DIARY; TRANSPORTATION; VALIDATION; POLLUTANTS; MATTER;
D O I
10.1038/jes.2012.28
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The objectives of this study were to measure particulate pollution (PM10, PM2.5, and PM1.0) continuously (24 h/day for 7 day) using real-time exposure monitoring and to estimate total inhalation mass using breathing rate and time-activity. Breathing rates were calculated from measured heart rates. Participants were asked to record a time-activity diary every 15 min. Five microenvironments were defined based on the time-activity diary: home, workplace/school, other indoor, outdoor, and transportation. The average masses of inhaled PM10 were 530, 316, and 280 mu g/day for two office workers, a housewife, and three students, respectively; those of PM2.5 were 316, 279, and 210 mu g/day; and those of PM1.0 were 251, 264, and 187 mu g/day, respectively. We found that home and office/school microenvironments were the main contributors of PM10, PM2.5, and PM1.0 inhaled mass during weekdays and weekends because dwelling time was a determinant factor for inhaled mass. Considering microenvironmental concentration, breathing rate, and dwelling time in each microenvironment, indoor home microenvironments were the largest source of particulate inhalation, followed in order by workplace, transportation, other indoor, and outdoor microenvironments. 34.6% and 69.6% of PM10 inhalation mass were accumulated in home microenvironments during weekdays and weekends, respectively. The inhaled mass of particulate <1.0 mu m (PM1.0) in size occupied largest, followed in order by particulate 10-2.5 mu m (coarse particle) and 2.5-1.0 mu m in size for all occupations.
引用
收藏
页码:344 / 351
页数:8
相关论文
共 50 条
  • [31] Estimation of ambient and non-ambient components of particulate matter exposure from a personal monitoring panel study
    William E Wilson
    Michael Brauer
    Journal of Exposure Science & Environmental Epidemiology, 2006, 16 : 264 - 274
  • [32] Design of a High-Sensitivity Ambient Particulate Matter 2.5 Particle Detector for Personal Exposure Monitoring Devices
    Chiang, Cheng-Ta
    IEEE SENSORS JOURNAL, 2018, 18 (01) : 165 - 169
  • [33] Monitoring children's personal exposure to airborne particulate matter in London, UK - method development and study design
    Wheeler, AJ
    Beaumont, R
    Hamilton, RS
    Farrow, S
    SCIENCE OF THE TOTAL ENVIRONMENT, 1999, 235 (1-3) : 397 - 398
  • [34] Design and application of a web-based real-time personal PM2.5 exposure monitoring system
    Sun, Qinghua
    Zhuang, Jia
    Du, Yanjun
    Xu, Dandan
    Li, Tiantian
    SCIENCE OF THE TOTAL ENVIRONMENT, 2018, 627 : 852 - 859
  • [35] Estimation of ambient and non-ambient components of particulate matter exposure from a personal monitoring panel study
    Wilson, William E.
    Brauer, Michael
    JOURNAL OF EXPOSURE SCIENCE AND ENVIRONMENTAL EPIDEMIOLOGY, 2006, 16 (03) : 264 - 274
  • [36] A new real-time personal dosimeter with position monitoring based on a scintillator
    Sun Young Moon
    Myonggeun Yoon
    Sun-Young Kim
    Dongho Shin
    Journal of the Korean Physical Society, 2021, 78 : 1133 - 1140
  • [37] A new real-time personal dosimeter with position monitoring based on a scintillator
    Moon, Sun Young
    Yoon, Myonggeun
    Kim, Sun-Young
    Shin, Dongho
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2021, 78 (11) : 1133 - 1140
  • [38] Continuous determination of fine particulate matter mass in the Salt Lake City Environmental Monitoring Project: A comparison of real-time and conventional TEOM monitor results
    Long, RW
    Eatough, NL
    Eatough, DJ
    Meyer, MB
    Wilson, WE
    JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2005, 55 (12): : 1839 - 1846
  • [39] Real-time particulate fallout contamination monitoring technology development at NASA Kennedy Space Center
    Mogan, PA
    Schwindt, CJ
    OPTICAL SYSTEMS CONTAMINATION AND DEGRADATION, 1998, 3427 : 138 - 145
  • [40] Empirical studies on emission factors for real-time particulate matter 2.5 monitoring at construction sites
    Yoon, Sihoo
    Won, Daeyoun
    Chi, Seokho
    JOURNAL OF CLEANER PRODUCTION, 2023, 384