Impact of Drug-Eluting Stents on Distal Vessels

被引:7
|
作者
Wakabayashi, Kohei [1 ]
Mintz, Gary S. [2 ,3 ]
Weissman, Neil J. [1 ]
Stone, Gregg W. [2 ,3 ]
Ellis, Stephen G. [4 ]
Grube, Eberhard
Ormiston, John A. [5 ]
Turco, Mark A. [6 ]
Pakala, Rajbabu [1 ]
Xue, Zhenyi [1 ]
Desale, Sameer [1 ]
Laynez-Carnicero, Ana [1 ]
Romaguera, Rafael [1 ]
Sardi, Gabriel [1 ]
Pichard, Augusto D. [1 ]
Waksman, Ron [1 ]
机构
[1] Washington Hosp Ctr, Washington, DC 20010 USA
[2] Columbia Univ, Med Ctr, New York, NY USA
[3] Cardiovasc Res Fdn, New York, NY USA
[4] Cleveland Clin, Cleveland, OH 44106 USA
[5] N Shore Hosp, Auckland, New Zealand
[6] Washington Adventist Hosp, Takoma Pk, MD USA
关键词
distal vessel; drug-eluting stent; vessel response; INTRAVASCULAR ULTRASOUND ANALYSIS; CORONARY ENDOTHELIAL DYSFUNCTION; BARE-METAL STENT; SHEAR-STRESS; ARTERY-DISEASE; LOCAL-DELIVERY; FOLLOW-UP; TAXUS-IV; SIROLIMUS; PACLITAXEL;
D O I
10.1161/CIRCINTERVENTIONS.111.965780
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Previous studies have not addressed vessel response >5 mm distal to the stent edge. Therefore, we investigated the impact of paclitaxel-eluting stents (PES) versus bare metal stents (BMS) on distal vessels in the serial intravascular ultrasound substudies of TAXUS IV, V, and VI. Methods and Results-TAXUS IV, V, and VI were double-blind, randomized, multicenter, controlled trials comparing PES with BMS. In their intravascular ultrasound substudies, 103 patients (54 BMS, 49 PES) had intravascular ultrasound data >= 10 mm distal to the stent both postprocedure and at 9 months follow-up. Baseline characteristics were similar between the 2 groups. Multilevel modeling was used to account for the variation between patients and within patients among distal segments. Effect of stent type, time, and their interaction was tested using a mixed effect model controlling for distal segments. Postprocedure lumen and vessel were not significantly different between PES versus BMS; however, lumen (P=0.006) and vessel (P=0.0001) were significantly reduced for BMS at 9-month follow-up but not for PES. Conversely, there was a significant plaque increase from postprocedure to 9-month follow-up for PES (P=0.0008) but not for BMS. These vessel responses were statistically consistent among 0- to 5-mm versus 5- to 10-mm versus 10- to 15-mm segments distal to the stent in both groups. Conclusions-PES use was associated with plaque increase from baseline to 9-month follow-up >5 mm distal to the stent along with positive remodeling, whereas BMS use was associated with negative remodeling and no plaque increase. These vessel responses were consistent in 5- mm long subsegments: 0 to 5 mm versus 5 to 10 mm versus 10 to 15 mm distal to the stent. Clinical Trial Registration-URL: http://www.clinicaltrial.gov. Unique identifiers: TAXUS IV-NCT00292474; TAXUS V-NCT00301522; TAXUS VI-NCT00297804. (Circ Cardiovasc Interv. 2012;5:211-219.)
引用
收藏
页码:211 / 219
页数:9
相关论文
共 50 条
  • [41] Drug-Coated Balloons in Small Vessels Preferred Strategy to Drug-Eluting Stents?
    Abbott, J. Dawn
    Wykrzykowska, Joanna J.
    Lenselink, Chris
    JACC-CARDIOVASCULAR INTERVENTIONS, 2023, 16 (09) : 1062 - 1064
  • [42] All drug-eluting stents are equal, but some drug-eluting stents are more equal than others
    Strauss, Bradley H.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (07) : 1310 - 1311
  • [43] Complications of Polymers on Drug-eluting Stents: Looking Toward Polymer-free Drug-eluting Stents
    Aoki, Jiro
    INTERNAL MEDICINE, 2015, 54 (06) : 549 - 550
  • [44] What will be the impact of drug-eluting stents on hybrid coronary revascularization?
    Karamanoukian, HL
    Aoukar, PS
    HEART SURGERY FORUM, 2002, 5 (04): : E24 - E27
  • [45] Drug-Eluting versus Bare Metal Stents for the Treatment of Large Coronary Vessels
    Lee, Yong Whan
    Chun, Kook Jin
    Lee, Hna Chul
    Kim, Jun
    Kim, June Hong
    Hong, Taek Jong
    Shin, Young Woo
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 103 (9A): : 63B - 63B
  • [46] Financial impact of drug-eluting stents: The US academic experience
    Marks, DS
    Ratko, TA
    Matuszewski, KA
    Oinonen, MJ
    Cummings, JP
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 402A - 402A
  • [47] Drug-Eluting Balloons and Drug-Eluting Stents in the Treatment of Peripheral Vascular Disease
    Lindquist, Jonathan
    Schramm, Kristofer
    SEMINARS IN INTERVENTIONAL RADIOLOGY, 2018, 35 (05) : 443 - 452
  • [48] Only specific coronary drug-eluting stents interfere with distal microvascular function
    Van den Heuvel, M.
    Sorop, O.
    Batenburg, W. W.
    Krabbendam, S. C.
    Van Beusekom, H. M. M.
    Duncker, D. J.
    Danser, A. H. J.
    Van der Giessen, W. J.
    EUROPEAN HEART JOURNAL, 2009, 30 : 533 - 533
  • [49] Optimization of Drug Delivery by Drug-Eluting Stents
    Bozsak, Franz
    Gonzalez-Rodriguez, David
    Sternberger, Zachary
    Belitz, Paul
    Bewley, Thomas
    Chomaz, Jean-Marc
    Barakat, Abdul I.
    PLOS ONE, 2015, 10 (06):
  • [50] Drug-eluting stents below the knee
    Bosiers, M.
    Deloose, K.
    Callaert, J.
    Keirse, K.
    Verbist, J.
    Peeters, P.
    JOURNAL OF CARDIOVASCULAR SURGERY, 2011, 52 (02): : 231 - 234