Optimization of Drug Delivery by Drug-Eluting Stents

被引:46
|
作者
Bozsak, Franz [1 ]
Gonzalez-Rodriguez, David [1 ]
Sternberger, Zachary [1 ]
Belitz, Paul [2 ]
Bewley, Thomas [2 ]
Chomaz, Jean-Marc [1 ]
Barakat, Abdul I. [1 ]
机构
[1] Ecole Polytech, CNRS, Lab Hydrodynam LadHyX, F-91128 Palaiseau, France
[2] Univ Calif San Diego, Dept MAE, UCSD Flow Control & Coordinated Robot Labs, La Jolla, CA USA
来源
PLOS ONE | 2015年 / 10卷 / 06期
关键词
VASCULAR SMOOTH-MUSCLE; OPTICAL COHERENCE TOMOGRAPHY; DERIVATIVE-FREE OPTIMIZATION; RELEASE KINETICS; CORONARY STENTS; NEOINTIMAL COVERAGE; CELL PROLIFERATION; COATED BALLOONS; IN-VITRO; PACLITAXEL;
D O I
10.1371/journal.pone.0130182
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Drug-eluting stents (DES), which release anti-proliferative drugs into the arterial wall in a controlled manner, have drastically reduced the rate of in-stent restenosis and revolutionized the treatment of atherosclerosis. However, late stent thrombosis remains a safety concern in DES, mainly due to delayed healing of the endothelial wound inflicted during DES implantation. We present a framework to optimize DES design such that restenosis is inhibited without affecting the endothelial healing process. To this end, we have developed a computational model of fluid flow and drug transport in stented arteries and have used this model to establish a metric for quantifying DES performance. The model takes into account the multi-layered structure of the arterial wall and incorporates a reversible binding model to describe drug interaction with the cells of the arterial wall. The model is coupled to a novel optimization algorithm that allows identification of optimal DES designs. We show that optimizing the period of drug release from DES and the initial drug concentration within the coating has a drastic effect on DES performance. Paclitaxel-eluting stents perform optimally by releasing their drug either very rapidly (within a few hours) or very slowly (over periods of several months up to one year) at concentrations considerably lower than current DES. In contrast, sirolimus-eluting stents perform optimally only when drug release is slow. The results offer explanations for recent trends in the development of DES and demonstrate the potential for large improvements in DES design relative to the current state of commercial devices.
引用
收藏
页数:29
相关论文
共 50 条
  • [1] Drug Release Analysis and Optimization for Drug-Eluting Stents
    Li, Hongxia
    Zhang, Yihao
    Zhu, Bao
    Wu, Jinying
    Wang, Xicheng
    [J]. SCIENTIFIC WORLD JOURNAL, 2013,
  • [2] Drug-eluting stents: an innovative multidisciplinary drug delivery platforms
    Burt, HM
    Hunter, WL
    [J]. ADVANCED DRUG DELIVERY REVIEWS, 2006, 58 (03) : 345 - 346
  • [3] Drug-eluting stents
    Anderson, H. Vernon
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (21) : 2025 - 2027
  • [4] Drug-eluting stents
    Scheller, B
    [J]. ZEITSCHRIFT FUR KARDIOLOGIE, 2004, 93 (09): : 646 - 648
  • [5] Drug-eluting stents
    不详
    [J]. MEDICAL LETTER ON DRUGS AND THERAPEUTICS, 2003, 45 (1152): : 23 - 24
  • [6] Drug-Eluting Stents
    Velagapudi, Chetan
    Madassery, Sreekumar
    [J]. SEMINARS IN INTERVENTIONAL RADIOLOGY, 2022, 39 (04) : 400 - 405
  • [7] Drug-eluting stents
    Ma, Xiaodong
    Wu, Tim
    Robich, Michael P.
    Wang, Xingwei
    Wu, Hao
    Buchholz, Bryan
    McCarthy, Stephen
    [J]. INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2010, 3 (03): : 192 - 201
  • [8] Drug-eluting stents
    Maisel, William H.
    Laskey, Warren K.
    [J]. CIRCULATION, 2007, 115 (17) : E426 - E427
  • [9] Drug-eluting stents
    Woods, TC
    Marks, AR
    [J]. ANNUAL REVIEW OF MEDICINE, 2004, 55 : 169 - 178
  • [10] Drug-eluting stents
    Popma, Jeffrey J.
    Tulli, Mark
    [J]. CARDIOLOGY CLINICS, 2006, 24 (02) : 217 - +