Repeatability of In Vivo Parafoveal Cone Density and Spacing Measurements

被引:126
|
作者
Garrioch, Robert [2 ,3 ]
Langlo, Christopher [4 ]
Dubis, Adam M.
Cooper, Robert F. [5 ]
Dubra, Alfredo [5 ,6 ,7 ]
Carroll, Joseph [1 ,5 ,6 ,7 ]
机构
[1] Med Coll Wisconsin, Inst Eye, Dept Cell Biol Neurobiol & Anat, Milwaukee, WI 53226 USA
[2] Med Coll Wisconsin, Summer Program Undergrad Res, Milwaukee, WI 53226 USA
[3] Cardiff Univ, Cardiff, S Glam, Wales
[4] Med Coll Wisconsin, Med Scientist Training Program, Milwaukee, WI 53226 USA
[5] Marquette Univ, Dept Biomed Engn, Milwaukee, WI 53233 USA
[6] Med Coll Wisconsin, Dept Ophthalmol, Milwaukee, WI 53226 USA
[7] Med Coll Wisconsin, Dept Biophys, Milwaukee, WI 53226 USA
基金
美国国家卫生研究院;
关键词
retina; cones; adaptive optics; repeatability; photoreceptors; PHOTORECEPTOR PACKING DENSITY; ADAPTIVE-OPTICS; RETINAL MOSAICS; RESOLUTION; REFLECTANCE; DISRUPTION; VISION;
D O I
10.1097/OPX.0b013e3182540562
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To assess the repeatability and measurement error associated with cone density and nearest neighbor distance (NND) estimates in images of the parafoveal cone mosaic obtained with an adaptive optics scanning light ophthalmoscope (AOSLO). Methods. Twenty-one participants with no known ocular pathology were recruited. Four retinal locations, approximately 0.65 degrees eccentricity from the center of fixation, were imaged 10 times in randomized order with an AOSLO. Cone coordinates in each image were identified using an automated algorithm (with or without manual correction) from which cone density and NND were calculated. Owing to naturally occurring fixational instability, the 10 images recorded from a given location did not overlap entirely. We thus analyzed each image set both before and after alignment. Results. Automated estimates of cone density on the unaligned image sets showed a coefficient of repeatability of 11,769 cones/mm(2) (17.1%). The primary reason for this variability appears to be fixational instability, as aligning the 10 images to include the exact same retinal area results in an improved repeatability of 4358 cones/mm(2) (6.4%) using completely automated cone identification software. Repeatability improved further by manually identifying cones missed by the automated algorithm, with a coefficient of repeatability of 1967 cones/mm(2) (2.7%). NND showed improved repeatability and was generally insensitive to the undersampling by the automated algorithm. Conclusions. As our data were collected in a young, healthy population, this likely represents a best-case estimate for corresponding measurements in patients with retinal disease. Similar studies need to be carried out on other imaging systems (including those using different imaging modalities, wavefront correction technology, and/or image analysis software), as repeatability would be expected to be highly sensitive to initial image quality and the performance of cone identification algorithms. Separate studies addressing intersession repeatability and interobserver reliability are also needed. (Optom Vis Sci 2012;89:632-643)
引用
收藏
页码:632 / 643
页数:12
相关论文
共 50 条
  • [41] THE SPREAD OF ADAPTATION IN HUMAN FOVEAL AND PARAFOVEAL CONE VISION
    CICERONE, CM
    HAYHOE, MM
    MACLEOD, DIA
    VISION RESEARCH, 1990, 30 (11) : 1603 - 1615
  • [42] FOVEAL AND PARAFOVEAL CONE ELECTRORETINOGRAMS IN JUVENILE MACULAR DEGENERATION
    SANDBERG, MA
    HANSON, AH
    BERSON, EL
    OPHTHALMIC PAEDIATRICS AND GENETICS, 1983, 3 (02): : 83 - 87
  • [43] STRING EFFECTS IN LOW DENSITY CONE DRAG MEASUREMENTS
    PASSMORE, RD
    KRAIGE, LG
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1970, 15 (11): : 1541 - &
  • [44] Significant Correlation between Contrast Sensitivity and Parafoveal Cone Density in Normal Eyes and Eyes with Retinal Degeneration.
    Hirota, Masakazu
    Kanda, Hiroyuki
    Endo, Takao
    Miyagawa, Suguru
    Miyoshi, Tomomitsu
    Morimoto, Takeshi
    Fujikado, Takashi
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [45] Use of multiple metrics to describe the parafoveal cone mosaic
    Lombardo, Marco
    Serrao, Sebastiano
    Ducoli, Pietro
    Lombardo, Giuseppe
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [46] Repeatability of automated vessel density measurements using optical coherence tomography angiography
    Al-Sheikh, Mayss
    Tepelus, Tudor Cosmin
    Nazikyan, Tigran
    Sadda, SriniVas R.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2017, 101 (04) : 449 - 452
  • [47] EFFECT OF A BACKGROUND ON FOVEAL AND PARAFOVEAL CONE DARK-ADAPTATION
    KOOIJMAN, AC
    STENEKER, FWM
    SMEETS, JLRM
    VISION RESEARCH, 1978, 18 (10) : 1381 - 1385
  • [48] Repeatability of astigmatism measurements
    Walline, JJ
    Kinney, KA
    Mutti, DO
    Zadnik, K
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 3965 - 3965
  • [49] Repeatability of ocular surface vessel density measurements with optical coherence tomography angiography
    Sijie Cai
    Fengping Zhao
    Chixin Du
    BMC Ophthalmology, 19
  • [50] Repeatability of electroretinogram measurements
    Or, Chi Mong
    Ghoraba, Hashem
    Zaidi, Moosa
    Akhavanrezayat, Amir
    Regenold, Jonathan
    Uludag, Gunay
    Yasar, Cigdem
    Park, SungWho
    Than, Ngoc
    Hwang, Jaclyn Joyce
    Nguyen, Quan Dong
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)