Repeatability of In Vivo Parafoveal Cone Density and Spacing Measurements

被引:126
|
作者
Garrioch, Robert [2 ,3 ]
Langlo, Christopher [4 ]
Dubis, Adam M.
Cooper, Robert F. [5 ]
Dubra, Alfredo [5 ,6 ,7 ]
Carroll, Joseph [1 ,5 ,6 ,7 ]
机构
[1] Med Coll Wisconsin, Inst Eye, Dept Cell Biol Neurobiol & Anat, Milwaukee, WI 53226 USA
[2] Med Coll Wisconsin, Summer Program Undergrad Res, Milwaukee, WI 53226 USA
[3] Cardiff Univ, Cardiff, S Glam, Wales
[4] Med Coll Wisconsin, Med Scientist Training Program, Milwaukee, WI 53226 USA
[5] Marquette Univ, Dept Biomed Engn, Milwaukee, WI 53233 USA
[6] Med Coll Wisconsin, Dept Ophthalmol, Milwaukee, WI 53226 USA
[7] Med Coll Wisconsin, Dept Biophys, Milwaukee, WI 53226 USA
基金
美国国家卫生研究院;
关键词
retina; cones; adaptive optics; repeatability; photoreceptors; PHOTORECEPTOR PACKING DENSITY; ADAPTIVE-OPTICS; RETINAL MOSAICS; RESOLUTION; REFLECTANCE; DISRUPTION; VISION;
D O I
10.1097/OPX.0b013e3182540562
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To assess the repeatability and measurement error associated with cone density and nearest neighbor distance (NND) estimates in images of the parafoveal cone mosaic obtained with an adaptive optics scanning light ophthalmoscope (AOSLO). Methods. Twenty-one participants with no known ocular pathology were recruited. Four retinal locations, approximately 0.65 degrees eccentricity from the center of fixation, were imaged 10 times in randomized order with an AOSLO. Cone coordinates in each image were identified using an automated algorithm (with or without manual correction) from which cone density and NND were calculated. Owing to naturally occurring fixational instability, the 10 images recorded from a given location did not overlap entirely. We thus analyzed each image set both before and after alignment. Results. Automated estimates of cone density on the unaligned image sets showed a coefficient of repeatability of 11,769 cones/mm(2) (17.1%). The primary reason for this variability appears to be fixational instability, as aligning the 10 images to include the exact same retinal area results in an improved repeatability of 4358 cones/mm(2) (6.4%) using completely automated cone identification software. Repeatability improved further by manually identifying cones missed by the automated algorithm, with a coefficient of repeatability of 1967 cones/mm(2) (2.7%). NND showed improved repeatability and was generally insensitive to the undersampling by the automated algorithm. Conclusions. As our data were collected in a young, healthy population, this likely represents a best-case estimate for corresponding measurements in patients with retinal disease. Similar studies need to be carried out on other imaging systems (including those using different imaging modalities, wavefront correction technology, and/or image analysis software), as repeatability would be expected to be highly sensitive to initial image quality and the performance of cone identification algorithms. Separate studies addressing intersession repeatability and interobserver reliability are also needed. (Optom Vis Sci 2012;89:632-643)
引用
收藏
页码:632 / 643
页数:12
相关论文
共 50 条
  • [21] Repeatability and Reproducibility of Quantifying Parafoveal Vessel Density in Normal Subjects with OCT-based Microangiography
    Chu, Zhongdi
    Zhang, Qinqin
    Chen, Chieh-Li
    Luo, Fengyi
    Lee, Cecilia
    Kinyoun, James L.
    Wang, Ruikang K.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [22] In Vivo Measurements of Cone Photoreceptor Spacing in Myopic Eyes from Images Obtained by an Adaptive Optics Fundus Camera
    Yoshiyuki Kitaguchi
    Kenichiro Bessho
    Tatsuo Yamaguchi
    Naoki Nakazawa
    Toshifumi Mihashi
    Takashi Fujikado
    Japanese Journal of Ophthalmology, 2007, 51 : 456 - 461
  • [23] In vivo measurements of cone photoreceptor spacing in myopic eyes from images obtained by an adaptive optics fundus camera
    Kitaguchi, Yoshiyuki
    Bessho, Kenichiro
    Yamaguchi, Tatsuo
    Nakazawa, Naoki
    Mihashi, Toshifumi
    Fujikado, Takashi
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2007, 51 (06) : 456 - 461
  • [24] Repeatability and Reproducibility of in-vivo Brain Temperature Measurements
    Sharma, Ayushe A.
    Nenert, Rodolphe
    Mueller, Christina
    Maudsley, Andrew A.
    Younger, Jarred W.
    Szaflarski, Jerzy P.
    FRONTIERS IN HUMAN NEUROSCIENCE, 2020, 14
  • [25] Repeatability and reliability of density and morphology measurements of corneal and conjunctival epithelial dendritic cells using in vivo confocal microscopy
    Alghamdi, Ali
    Tajbakhsh, Zahra
    Jalbert, Isabelle
    Stapleton, Fiona
    Golebiowski, Blanka
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (08)
  • [26] Intraobserver Repeatability and Interobserver Reproducibility of Foveal Cone Density Measurements in CNGA3- and CNGB3-Associated Achromatopsia
    Georgiou, Michalis
    Litts, Katie M.
    Singh, Navjit
    Kane, Thomas
    Patterson, Emily J.
    Hirji, Nashila
    Kalitzeos, Angelos
    Dubra, Alfredo
    Michaelides, Michel
    Carroll, Joseph
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2020, 9 (07): : 1 - 10
  • [27] Assessment of parafoveal cone density in patients taking hydroxychloroquine in the absence of clinically documented retinal toxicity
    Debellemaniere, Guillaume
    Flores, Mathieu
    Tumahai, Perle
    Meillat, Mathieu
    Garnier, Melanie Bidaut
    Delbosc, Bernard
    Saleh, Maher
    ACTA OPHTHALMOLOGICA, 2015, 93 (07) : E534 - E540
  • [28] Normative database of cone spacing and density from adaptive optics montage
    Kalaparambath, Snega
    Cooper, Robert F.
    Vergilio, Grace
    Aguirre, Geoffrey K.
    Morgan, Jessica Ijams Wolfing
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [29] Accuracy and Repeatability of Anthropometric Facial Measurements Using Cone Beam Computed Tomography
    Fourie, Zacharias
    Damstra, Janalt
    Gerrits, Peter O.
    Ren, Yijin
    CLEFT PALATE-CRANIOFACIAL JOURNAL, 2011, 48 (05): : 623 - 630
  • [30] Parafoveal Cone Function in Choroideremia Assessed with Optoretinography
    Xu, Peiluo
    Cooper, Robert F.
    Jiang, Yu You
    Morgan, Jessica Ijams Wolfing
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)